- 27 -
The Current index helps to confirm the line's identity.
If an adjacent line is running parallel with the object line.
If two lines are crossing:
Locating T connection
Þ
Splicing/jointing points of Power cable, Telephone cable, Gas pipe, Water pipe, or Sewer pipe.
0.5m
Depth: 1.50 m
Current index: 2.6 mA
Line: A
Line: B
1.5m
0.5m
Line: A
Line: B
Line-A with a 2.6 mA current
index is the object line.
Even though signal is smaller.
The line with the highest current index is the object line into which the signal is being broadcast.
Þ
Line A with a 2.0 mA current index is the trace object.
Depth:
1.50 m
Current index: 1.5 mA
Depth:
1.50 m
Current index:
0.5 mA
Depth:
1.00 m
Current index: 1.0 mA
Depth: 0.50 m
Current index: 0.7 mA
A
C
B
Main line-A with a 1.5 mA current index
Line-B: Index value 1.0 mA
Þ
Main line
Line-C:
Index value 0.5 mA
Þ
Branch line
Depth: 1.50m
Current index: 2.0 mA
Depth: 0.50m
Current index: 1.0 mA
1.5m
Line: A
Line: B
Receiving
sensitivity