5-2. Receiver
1)Key function
Power ON / OFF
*Power save function: Automatically powers
off after 5~30 minutes of inactivity.
Adjusts signal sensitivity for PEAK MODE.
Depth measurement (High precision)
:
Press
DEPTH
key at the peak value spot.
Battery
compartment
Earphone plug
PC interface
connector
Sensor connector
(
Signal input terminal)
Frequency
Receiving
sensitivity
DEPTH
Bar-graph
Battery indication
POWER
Measuring Mode
GAIN
LOG
MODE
PEAK/NULL
FREQUENCY
Gain setting value
Depth
Current index:
Details page 26
Note: Current index is not displayed if probe is used.
Note: 100% is not the maximum peak value. When 100% appears, press Gain key again
until a new sharp peak value is obtained, that is not 100%.
When pressing the
Gain
key, sensitivity is adjusted automatically to 70%.
*
Semi-Automatic gain control
mode (AUTO GAIN)
POWER
GAIN
DEPTH
NULL
PEAK
PEAK & NULL MODE:
Maximum sensitivity is the point directly above the object line and the buried object line location is
indicated with arrow.
PEAK MODE
: Maximum sensitivity is the point directly above the object line.
NULL MODE:
Minimum sensitivity is the point directly above the object line. The buried object line location is indicated with
arrow.
Selects locating mode:
PEAK/NULL
LOG
* Manual gain control mode (MANU GAIN)
Press the
▼Gain
key, sensitivity is decreased.
Press the
▲Log
key, sensitivity is increased.
PEAK & NULL
Real time depth