background image

2

The lightning flash with arrowhead, within an equilateral 

triangle, is intended to alert the user to the presence of 

uninsulated “dangerous voltage” within the product’s en

-

closure that may be of sufficient magnitude to constitute 

a risk of electric shock to persons.

The exclamation point within an equilateral triangle is 

intended to alert the user to the presence of important 

operating and maintenance (servicing) instructions in 

the literature accompanying the appliance.

WARNING - TO REDUCE RISK OF FIRE  

OR ELECTRICAL SHOCK,  

DO NOT EXPOSE THIS EQUIPMENT  

TO RAIN OR MOISTURE

NO USER-SERVICEABLE PARTS IN-

SIDE. REFER SERVICING  

TO QUALIFIED PERSONNEL

To prevent the risk of electric shock,  

do not remove cover or back.  

No user-serviceable parts inside.

1. Read these instructions.

2. Keep these instructions.

3. Heed all warnings.

4. Follow all instructions.

5. Do not use this apparatus near water.

6. Clean only with a dry cloth.

7. Do not block any ventilation openings.  

Install in accordance with the manufacturer’s 

instructions.

8. Do not install near any heat sources such 

as radiators, heat registers, stoves, or other 

apparatus (including amplifiers) that produce 

heat.

9. Do not defeat the safety purpose of the polar-

ized or grounding-type plug. A polarized plug 

has two blades with one wider than the other. 

A grounding type plug has two blades and a 

third grounding prong. The wide blade or the 

third prong are provided for your safety. If 

the provided plug does not fit into your outlet, 

consult an electrician for replacement of the 

obsolete outlet.

10. Protect the power cord from being walked on 

or pinched particularly at plugs, convenience 

receptacles, and the point where they exit from 

the apparatus.

11. Only use attachments/accessories specified by 

the manufacturer.

12. Use only with the cart, stand, 

tripod, bracket, or table speci-

fied by the manufacturer, or 

sold with the apparatus. When 

a cart is used, use caution when 

moving the cart/apparatus combination to 

avoid injury from tip-over.

13. Unplug this apparatus during lightning storms 

or when unused for long periods of time.

14. Refer all servicing to qualified service person

-

nel. Servicing is required when the apparatus 

has been damaged in any way, such as 

power-supply cord or plug is damaged, liquid 

has been spilled or objects have fallen into the 

apparatus, the apparatus has been exposed to 

rain or moisture, does not operate normally, or 

has been dropped.

15. Do not expose this equipment to dripping or 

splashing and ensure that no objects filled 

with liquids, such as vases, are placed on the 

equipment.

16. To completely disconnect this equipment 

from the a.c. mains, disconnect the AC / DC 

Adapter from the a.c. receptacle.

17. The mains plug of the power supply cord 

shall remain readily operable. If the AC /

DC Adapter is provided with a mains power 

supply cord attachment, the plug of this power 

supply cord shall remain readily operable.

18. Do not expose batteries to excessive heat such 

as sunshine, fire or the like.

19. Connect mains power supply cord only to a 

mains socket outlet with a protective earthing 

connection.

WARNING:

 

Use this product only with  

the Power Adapter provided.

Failure to do so may result  

in fire and/or electrical shock.

IMPORTANT  

SAFETY INSTRUCTIONS!

PLEASE READ THEM BEFORE 

OPERATING THIS EQUIPMENT.

Copyright ©2022 by McIntosh Laboratory, Inc.

Содержание MR89

Страница 1: ...MR89 AM FM Tuner Owner s Manual McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 www mcintoshlabs com...

Страница 2: ...ower cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufactur...

Страница 3: ...Assistance 607 723 3512 Fax 607 724 0549 Customer Service 607 723 3515 Fax 607 723 1917 Email support mcintoshlabs com Website www mcintoshlabs com Please Take A Moment For future reference you can w...

Страница 4: ...e retained in Permanent Memory Balanced Outputs The Balanced Outputs allow connection of the MR89 to a Preamplifier using long cable lengths without a loss in sound quality Digital Audio Outputs There...

Страница 5: ...5 8 11 75cm 17 43 18cm 14 1 2 36 83cm 15 7 8 40 32cm 3 16 0 48cm 4 13 16 12 22cm 10 9 16 26 83cm 5 8 1 59cm 13 16 2 06cm 2 5 08cm 1 15 16 4 92cm 13 1 4 33 65cm M R 8 9 A M F M T U N E R PRESET TUNE M...

Страница 6: ...3 66cm in front of the mounting panel for knob clearance A custom cabinet installation should provide the minimum spacing dimensions for cool operation Allow at least 2 inches 5 08cm above the top 2...

Страница 7: ...ntrol signal and passes the light control signal received at power control in to another McIntosh Component when the MR89 is On 4 IR Input for connecting an IR Receiver 5 DATA IN receives operating da...

Страница 8: ...n outer shield and RJ45 connectors on each end shielded CAT5 CAT5e or CAT6 patch cable 2 Connect a 75 ohm coax cable from a FM Antenna or cable system to the MR89 75 OHM FM ANT Connector FM Antenna Mo...

Страница 9: ...9 A V Control Center Connect to AC Outlet How to Connect the MR89...

Страница 10: ...appropriate Tuner Balanced Audio In 2 Preamplifier or A V Control Center Balanced Input Connectors 8 Optionally connect an Audio Cable from the MR89 Tuner UNBALanced OUTPUT Jacks to the appropriate T...

Страница 11: ...ast Reverse Seek Down Navigate backwards through the current active media using this button This is also used to adjust the tuner downwards 22 23 24 14 Fast Forward Seek Up Navigate forward through th...

Страница 12: ...format artist song name and is shown on the Information Display 5 MONO SETUP Push button with indica tor combines the Left and Right Channel signals for Monophonic Sound on FM Stations it is also used...

Страница 13: ...ion Name Default Setting and the Page Number for additional information AM Seek Sensitivity AM reception and signal quality varies due to distance from the radio station radio station power output sou...

Страница 14: ...ding low and high frequencies the same amount High Blend blends the high frequency portion of the audio frequency range more aggressively The highest frequencies are always blended and as signal quali...

Страница 15: ...ed by rotating the Control to OFF 3 Proceed to the next Setup Menu Item or press the MONO SETUP Push button to exit the Setup Mode Highcut The MR89 provides a Highcut function which can be used to red...

Страница 16: ...next Setup Menu Item or press the MONO SETUP Push button to exit the Setup Mode Meter Lights Settings are ON OFF The rear panel Light Control signal always takes precedence over the Set Up Menu Refer...

Страница 17: ...LECT push button followed by the 1 push button Hold both push buttons down for approximately 5 seconds until the McIntosh LED at the top of the remote flashes once 4 Press the MONO SETUP Push button t...

Страница 18: ...or changing the receiving standards Note Changing the current Tuner Region will result in clearing of all the Station Presets 1 Press the MONO SETUP Push button until the Setup Mode is active Then rot...

Страница 19: ...down 1 channel at a time or the numerical keypad may be used to enter tune frequency directly The Front Panel Information Display will indicate the band and exact Tune Frequency and when the MR89 is r...

Страница 20: ...Station 3 To clear any additional Station Presets perform steps 1 and 2 again After the creation of Preset s use the Front Panel PRESET MENU Control to select the desired Station Preset or by using t...

Страница 21: ...FM radio Stations When available from a FM Broadcast Station the text information appears on the second line of the Front Panel Information Display Information longer than 20 characters will scroll fr...

Страница 22: ...edance 100 ohms Unbalanced or Balanced Digital Output Optical 15dbm to 21dbm PCM Coaxial 0 5Vp p 75 ohm PCM Sampling Frequency 48kHz PCM AM Antenna Input Balanced RJ45 connector for use only with supp...

Страница 23: ...ip ment for shipment the equipment must be packed exactly as shown below Use the original shipping carton and interior parts only if they are all in good serviceable condition If a shipping carton or...

Страница 24: ...cts is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice Printed in the U S A McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903 www mcin...

Отзывы: