background image

2

IMPORTANT SAFETY INSTRUCTIONS!

PLEASE READ THEM BEFORE OPERATING THIS EQUIPMENT.

General:

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.

5. Warning: To reduce risk of fire or electrical shock,

do not expose this equipment to rain or moisture.
This unit is capable of producing high sound pres-
sure levels. Continued exposure to high sound pres-
sure levels can cause permanent hearing impair-
ment or loss. User caution is advised and ear protec-
tion is recommended when playing at high volumes.

6. Disconnect this equipment when unused for long peri-

ods of time.

7. Only use attachments/accessories specified by the

manufacturer.

Installation:

8. Do not block any ventilation openings. Install in accor-

dance with the manufacturer’s instructions.

9. Do not install near any heat sources such as radiators,

heat ducts or other equipment that produce heat.

10. Do not use this equipment near water.
11. Do not expose this equipment to dripping or splashing

and ensure that no objects filled with liquids are
placed on the equipment.

12. Do not mount this product with an unstable bracket as

the equipment may fall, causing serious injury to a
person, and serious damage to the product.

Connection:

13. Route DC power cords so that they are not likely to be

pinched by items placed upon or against them, paying
particular attention to the point where they enter the
instrument.

Care of Equipment:

14. Clean only with dry cloth.
15. Do not permit objects or liquids of any kind to be

pushed, spilled and/or fall into the equipment through
enclosure openings.

Repair of Equipment:

16. Refer all servicing to qualified service personnel. Ser-

vicing is required when the equipment has been dam-
aged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen
into the equipment, the equipment has been exposed to
rain or moisture, does not operate normally, or has
been dropped.

17. Do not attempt to service beyond that described in the

operating instructions. All other service should be re-
ferred to qualified service personnel.

18. When replacement parts are required, be sure the ser-

vice technician has used replacement parts specified by
McIntosh or have the same characteristics as the origi-
nal part. Unauthorized substitutions may result in fire,
electric shock, or other hazards.

19. Upon completion of any service or repairs to this prod-

uct, ask the service technician to perform safety checks
to determine that the product is in proper operating
condition.

WARNING - TO REDUCE RISK OF

FIRE OR ELECTRICAL SHOCK, DO

NOT EXPOSE THIS EQUIPMENT TO

RAIN OR MOISTURE.

NO USER-SERVICEABLE PARTS

INSIDE. REFER SERVICING TO

QUALIFIED PERSONNEL.

To prevent the risk of electric shock, do not remove

bottom cover. No user serviceable parts inside.

Содержание MCC302M

Страница 1: ...MCC302M Owner s Manual McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 FAX 607 724 0549 MCC302 Power Amplifier...

Страница 2: ...y items placed upon or against them paying particular attention to the point where they enter the instrument Care of Equipment 14 Clean only with dry cloth 15 Do not permit objects or liquids of any k...

Страница 3: ...ber Purchase Date Dealer Name If it is determined that your McIntosh product is in need of repair you can return it to your dealer You can also return it to the McIntosh Laboratory Service Repair depa...

Страница 4: ...all channels to ensure the MCC302 will have a long and trouble free operating life Speaker Protection If for any reason a DC Direct Current voltage appears at the speaker output terminals a built in c...

Страница 5: ...ur MCC302 There is additional infor mation on the next page pertaining to installing the MCC302 into your vehicle Dimensions 13 21 32 34 69cm Top View of the MCC302 Side View of the MCC302 2 11 16 6 8...

Страница 6: ...ratures are restored operation will resume The amplifier can be mounted vertically or horizontally and may be located under a seat if adequate clearance is available The preferred installation method...

Страница 7: ...McIntosh Control Centers Cooling Fan Air Intake OUTPUT Connections for loudspeakers SUBWOOFER OUTPUTS supply a two channel summed output Receives the Amplifier Turn ON signal from a McIntosh Control...

Страница 8: ...ction illustrated below shows the SUB OUTput connected to a separate Subwoofer Power Amplifier and Subwoofer Loudspeaker Note The Subwoofer Outputs are line level outputs and summed from all the Input...

Страница 9: ...ected in a series parallel combina tion to the Amplifier s Channels 1 and 2 BRIDGE Left Front Right Front Vehicle Battery Fuse McIntosh Control Center Power Guard Amp ON McIntosh External Subwoofer Ro...

Страница 10: ...w roll off frequency high roll off frequency or flat frequency response SENSITIVITY Individual Input Sensi tivity Controls for Channels 1 and 2 SOURCE Switch selects either CHs 1 2 or 1 2 SUBwoofer Su...

Страница 11: ...REQUENCY Control to get an idea where in the musical spectrum the frequency numbers are located Then set the LEVEL Control back to 0 and listen to the system to deter mine its equalization needs Subtl...

Страница 12: ...and under Temporarily place the removed glass panel in a safe place remove the suction cup and save it for future use 4 Remove the Phillips Screws holding the End Caps on both sides of the amplifier a...

Страница 13: ...13 Block Diagram MCC302 Block Diagram...

Страница 14: ...ter Frequency is variable from 40Hz to 2 000Hz level variable 12db Q fixed at 2 Crossover Selectable High pass or Low pass The frequency is vari able from 50Hz to 120Hz The slope is 12dB per octave Lo...

Страница 15: ...elow failure to do so will result in shipping damage Make sure that the Top Glass Panel is firmly secured to the chassis using the supplied hex head screws Use the original shipping carton and interio...

Страница 16: ...ntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903 The continuous improvement of its products is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without...

Отзывы: