Input Mode Switch

The Input Mode Switch, which is located on the Rear 

Panel of the MC312, allows 

selection of either the Balanced 

or Unbalanced Input. Refer to 

figure 12.

Auto Off Switch

The MC312 incorporates Power Save Circuitry to 

automatically place the MC312 into the power saving 

Standby Mode approximately 30 minutes after there 

has been an absence of an audio input signal.

When there is a Power Control Connection be-

tween the MC312 and a Preamplifier with Power Save 

Circuitry, the AUTO OFF Switch is bypassed (located 

on the Rear Panel of the MC312). Refer to figure 13.

In the event there is no 

Power Control Connection 

and the Power Save Circuit-

ry is activating inappropri-

ately relative to your specific 

use of the MC312, place the 

AUTO OFF Switch in the DISABLE position.

Note: If the Power Save Circuitry has switched Power 

to the MC312 OFF, place the POWER in the OFF 

Position and then in the ON position to reset the 

circuitry.

Power On

To have the MC312 automatically turn On or Off 

when a Preamplifier or A/V Control Center turns On 

or Off, rotate the power switch to 

the Remote position. For man-

ual operation, rotate the power 

switch to the On or Off position 

as desired. Refer to figure 9.

Note: There must be a power 

control connection between 

the MC312 and the Audio 

Preamplifier (or A/V Con-

trol Center), in order for the remote power turn-on 

to function.

Meter Selection

Rotate the meter mode switch to select the meter 

operation mode you desire. 

Refer to figures 10 and 11.

Lights Off - Meter lights 

are turned off 

and the meter 

will continue 

to indicate 

the power 

output.

Note: When 

Power Control Input of the MC312 

is connected to an Audio Preampli-

fier or A/V Control Center with 

Remote Meter Illumination Control, 

the Meter Illumination will auto-

matically be remotely controlled 

(On/Off) with the METER Switch 

set to the WATTS or HOLD posi-

tion.

How to Operate

How to Operate

Figure 9

Figure 10

Figure 11

Figure 12

DISABLED

Figure 13

DISABLED

Watts- The meters respond to all the musi-

cal information being produced by the 

amplifier. They indicate to an accuracy 

of at least 95% of the power output with 

only a single cycle of a 2000Hz tone 

burst.

Hold - The meter pointer is locked to the high-

est power peak in a sequence of peaks. 

It is electronically held to this power 

level until a higher power peak passes 

through the amplifier. The meter point-

er will then rise to the newer higher 

indication. If no further power peaks 

are reached, the meter pointer will 

very slowly return to its rest position 

or lower power level. The decay rate is 

approximately 6dB per minute.

Note: The MC312 Power Output Meter 

indicates the actual power delivered 

to the loudspeakers by responding 

to the combination of current and 

voltage output.

Содержание MC312

Страница 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 www mcintoshlabs com MC312 Power Amplifier Owner s Manual...

Страница 2: ...rtant Additional Operation Information Guide Thank You and Please Take a Moment 2 Technical Assistance and Customer Service 2 Table of Contents 2 General Information 2 Connector and Cable Information...

Страница 3: ...n though the power line varies Illuminated Power Meters The Illuminated Power Output Watt Meters on the MC312 are peak responding and indicate the true power output of the amplifier The Peak Watt Hold...

Страница 4: ...for your MC312 Dimensions Front View of the MC312 Rear View of the MC312 Side View of the MC312 17 1 2 44 5cm 8 7 8 22 5cm 9 7 16 24 0cm 11 3 4 29 9cm 16 13 16 43 0cm DISABLED 20 50 8cm 3 16 0 5cm 16...

Страница 5: ...ble oper ating temperature A custom cabinet installation should provide the fol lowing minimum spacing dimensions for cool opera tion Allow at least 6 inches 15 24cm above the top 2 inches 5 08cm belo...

Страница 6: ...n tosh Component Unbalanced INput RIGHT Channel for an audio cable from a Preamplifier or A V Con trol Center audio output Unbalanced OUTput RIGHT Channel for an audio cable to the next Power Amplifie...

Страница 7: ...McIntosh MC312 Power Amplifier is designed for Loudspeakers with an impedance of 2 ohms 4 ohms or 8 ohms Connect a single Loudspeaker only to the Right and Left Output Terminals When connecting Loudsp...

Страница 8: ...Loudspeaker s impedance is in between the available connections use the nearest lower impedance connection Refer to General Informa tion Note 3 on page 2 for additional information WARNING Loudspeake...

Страница 9: ...ptional hookup is to use unbalanced cables and place the INPUT MODE Switch in the UNBALANCED Position 4 Connect XLR cables from the MC312 Power Amplifier 1 Audio Balanced OUTput LEFT and RIGHT to the...

Страница 10: ...uarter of a turn 90 Do not over tighten Refer to figure E on page 9 8 Referring to figure H connect the Loudspeaker hookup cables with ba nana plugs into the hole at the top of the terminal to the MC3...

Страница 11: ...11...

Страница 12: ...the display modes of the Power Output Meter and Meter Illumination Meter indicates the Right Channel Output of the amplifier LED indicates when the LEFT Channel Amplifier POWER GUARD circuit activate...

Страница 13: ...MC312 and the Audio Preamplifier or A V Con trol Center in order for the remote power turn on to function Meter Selection Rotate the meter mode switch to select the meter operation mode you desire Re...

Страница 14: ...can deliver the best possible performance from any type of high quality loudspeaker system Refer to figure 14 Creating an amplifier with this level of perfor mance did not come easily Many months of...

Страница 15: ...at is lower than optimum causes more output current to flow which results in extra heat being generated in the power output stage This increase in temperature will result in a reduced life expectancy...

Страница 16: ...se in sonic perfor mance with this circuit and it ensures safe operation of the amplifier under even the most extreme operat ing conditions The different types of protection circuits incorporated in t...

Страница 17: ...ntrol Out Jacks The Power Control signal from these jacks is delayed by a fraction of a second so that the turn on power surge of the next power amplifier occurs at a later time This helps prevent pow...

Страница 18: ...tor Greater than 40 Input Impedance 22 000 ohms Balanced 22 000 ohms Unbalanced Voltage Gain 29dB 8 Ohms 26dB 4 Ohms 23dB 2 Ohms Power Guard Less than 2 Total Harmonic Distortion with up to a 14dB ove...

Страница 19: ...shipping damage Use the original shipping carton and interior parts only if they are all in good serviceable condition If a shipping carton or any of the interior part s are needed please call or writ...

Страница 20: ...cts is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice Printed in the U S A McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903 www mcin...

Отзывы: