Power Requirements

Field AC Voltage conversion of the MC1502 is not 

possible. The MC1502 is factory configured for one 

of the following AC Voltages:

100V 

50/60Hz at 6.6 Amps

110V 

50/60Hz at 6.0 Amps

120V 

50/60Hz at 5.5 Amps

127V 

50/60Hz at 5.5 Amps

220V 

50/60Hz at 3.0 Amps

230V 

50/60Hz at 2.75 Amps

240V 

50/60Hz at 2.75 Amps

Standby: Less than 0.3 watts

Note: Refer to the right side panel of the MC1502 for the 

correct voltage.

Overall Dimensions

Width is 18 1/4 inches (46.4cm)

Height is 10 1/4 inches (26cm) 

Depth is 21 inches (53.3cm) including connectors

Weight

118 pounds (53.5 kg) net, 135 pounds (61.2 kg) in 

shipping carton

Shipping Carton Dimensions

Width is 26 1/2 inches (67.3cm)

Height is 15 1/2 inches (39.4cm)

Depth is 28 inches (71.1cm)

Power Output

Minimum sine wave continuous average power output 

per channel, both channels operating is:

150 watts into 2 ohm loads

150 watts into 4 ohm loads

150 watts into 8 ohm loads

Output Load Impedance

2, 4 or 8 ohms

Rated Power Band

20Hz to 20,000Hz

Total Harmonic Distortion

0.5% maximum harmonic distortion at any power 

level from 250 milliwatts to rated power, 20Hz to 

20,000Hz

Dynamic Headroom

1.2dB

Frequency Response

+0, -0.5dB from 20Hz to 20,000Hz

+0, -3.0dB from 10Hz to 70,000Hz

Input Sensitivity (for rated output)

1.7 Volts Unbalanced

3.4 Volts Balanced

Signal To Noise Ratio (A-Weighted)

112dB below rated output

Intermodulation Distortion

0.5% maximum, if the instantaneous peak power 

output does not exceed twice the rated power output 

for any combination of frequencies from 20Hz to 

20,000Hz.

Wide Band Damping Factor

Greater than 18

Input Impedance

47,000 ohms Unbalanced

20,000 ohms Balanced

Power Control Input

5-15VDC, less than 1mA

Power Control Output

12VDC, 25mA

Output is 0.2 seconds from turn On.

Tube Compliment

4 - 12AX7A Input and Phase Inverter

4 - 12AT7 Voltage Amplifier and Driver

8 - KT88 Power Output

Specifications

Specifications

Содержание MC1502

Страница 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 www mcintoshlabs com MC1502 Power Amplifier Owner s Manual...

Страница 2: ...to your Dealer You can also return it to the McIntosh Laboratory Service Department For assistance on factory repair return procedure contact the McIntosh Service Department at McIntosh Laboratory In...

Страница 3: ...3 IMPORTANT INSTRUCTIONS FOR REMOVAL OF FOAM INSERT OVER THE VACUUM TUBES PRIOR TO CONNECTING THE A C POWER SUPPLY CORD START ON THE NEXT PAGE...

Страница 4: ...Shield Metal Cover from the MC1502 Refer to figure 3C 4 Place the Tube Cover and the previously removed chassis screws in a safe location as the Tube Cover will be reinstalled 5 Carefully lift up and...

Страница 5: ...Ventilation Unpacking the MC1502 and Ventilation OFF ON N OF Figure 3C Figure 6F OFF ON N OF Figure 7G Figure 8A Screw Metal Tube Cover Metal Hex Tube Cover Support Hot Surface Tag Washer Figure 9 Hot...

Страница 6: ...is enabled For additional information including how to disable it refer to page 13 4 When Power Amplifier Protection Circuitry Sentry Monitor of the MC1502 has activated the Small Vacuum LED Illuminat...

Страница 7: ...e for the plates The secondary winding is wound together with the primary windings This provides very close primary to secondary coupling The result is flat frequency response and wide power bandwidth...

Страница 8: ...CONTROL INPUT MODE AUTO OFF COM R OUTPUT CLASS 2 WIRING COM L OUTPUT CLASS 2 WIRING MC1502 POWER A MPL IFIER McINTOSH LABORATORY INC BINGHAMTON NY HANDCRAFTED IN USA WITH US AND IMPORTED PARTS BALANC...

Страница 9: ...s LEFT OUTPUTS for Class 2 Wiring Connections for a 2 4 or 8 ohm Loudspeakers FUSE HOLDER refer to the nomenclature next to the fuse holder to deter mine the correct fuse size and rating CONNECT the M...

Страница 10: ...Power Amplifier Bare wire cable ends Carefully remove sufficient insulation from the cable ends refer to figures 1 2 3 If the cable is stranded carefully twist the strands together as tightly as possi...

Страница 11: ...wer impedance connection Refer to General Information Note 6 on page 6 for additional information WARNING Loudspeaker Terminals are hazardous live and present a risk of electric shock For additional i...

Страница 12: ...lumination Sentry Protection Circuitry is Activated Right Channel Small Signal Vacuum Tubes LED Illumination Color Operation Mode Function Amber Warm up Audio Signal is muted Green Normal Selected by...

Страница 13: ...e to Green The Illumination of Small Signal Vacuum Tubes can also be switched OFF by placing the TUBE LIGHT Control in the OFF position Tube Lights Control The eight Small Signal Vacuum Tubes are Illu...

Страница 14: ...0 watts into 2 ohm loads 150 watts into 4 ohm loads 150 watts into 8 ohm loads Output Load Impedance 2 4 or 8 ohms Rated Power Band 20Hz to 20 000Hz Total Harmonic Distortion 0 5 maximum harmonic dist...

Страница 15: ...is will ensure the proper equipment location on the bottom foam pad Failure to do this will result in shipping damage To protect the tubes during shippment the Foam Insert removed from the MC1502 need...

Страница 16: ...cts is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice Printed in the U S A McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903 www mcin...

Отзывы: