Under the condition of protection
,
the
overload
indicator
light
(
red
)
is on,the
"RESET"
button can
recover the output of the generator,
and
unnecessary to restart engine overall.
●
Press and hold the
“RESET”
button for one
second
,
until
the overload indicator light (red)
will be off, and output indicator light (green) will
be on.
<<09>>
NOTE
When a high load electrical appliance is
connected instantaneously, in order to reduce
voltage change, turn the economy control
switch to the
“OFF”
( )position.
In
DC
operation, turn the economy control
switch to the
“OFF”
( )position.
Connect both
AC
load and
DC
load
,
turn the
economy control
switch to the
“OFF”
( )
position.
■
■
■
3
.
3
) Reset
NOTE
For protection condition, the output indicator
light (green) is off, and the overload indicator
light (red) is on.
Every starting the engine the
"
"
button is
available within 5 times. Otherwise, you need
restart the engine.
RESET
■
■
“OFF”
)
When the economy control switch turns to the
“OFF”
( ) engine
runs at high speed.
(
●
Under the non-overloading condition,
the
"RESET" is supposed to be ineffective.