NOTE
The
AC
receptacle can be used while the
DC
power is in use. If use both at same time, be
sure not to exceed the total power for
AC
and
DC. (AC:0.9kVA,DC:5A)
Most of motor appliances
require more than
their rated wattage, when starting.
■
■
6.1) DC Application
The DC receptacle
,
15-30V
under no-load condition,
may be used for charging 12V battery only.
NOTE
In DC operation, turn the
ECON.SW
to the
"OFF”
( ) position.
6.1.1)
Connect the
DC
receptacle to battery
terminals
with the charging cable.
■
WARNING
●
For continuous operation, do not exceed the
rated out-put power of generator.
●
Do not make parallel connection with other
generators.
●
Do not connect an extension to the exhaust
pipe.
●
When an extension cable is required, be sure to
use a tough rubber sheathed flexible cable
(according to IEC245 or equivalent standards).
The length of the extension cable: 60m for
2
2
cable of 1.5mm ; 100m for cable of 2.5mm .
●
Keep away from other electric cables or wires.
<<16>>