12
4111-0015 — Apr. 2020
© 2020 Systems, LLC
TOLERANCES
(UNLESS OTHERWISE NOTED)
FRACTIONAL:
1/32"
DECIMAL:
.00 =
.01"
.000 =
.005"
ANGULAR:
1
DRAWN BY
CHECKED BY
DRAWING NO.
DATE
BDK
1/27/2020
S Y S T E M S
L o a d i n g D o c k E q u i p m e n t
P O W E R A M P
M C G U I R E
D L M
This print is the property of Systems, LLC and represents a proprietary article in which Systems, LLC retains any and all patent and other rights, including exclusive rights
of use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufacture the article or articles shown therein,
such permission to be granted only by written authorization signed by an officer or other authorized agent of Systems, LLC thereof.
MATERIAL
STOCK NO.
INSTALLATION
OVERVIEW VIEW 2
REV A - ECN 18-066
Low Pit Floor (distance from pit floor to drive under 24”)
TOLERANCES
(UNLESS OTHERWISE NOTED)
FRACTIONAL:
1/32"
DECIMAL:
.00 =
.01"
.000 =
.005"
ANGULAR:
1
DRAWN BY
CHECKED BY
DRAWING NO.
DATE
BDK
12/1/2017
S Y S T E M S, I N C.
L o a d i n g D o c k E q u i p m e n t
P O W E R A M P
M C G U I R E
D L M
This print is the property of Systems, Inc. and represents a proprietary article in which Systems, Inc. retains any and all patent and other rights, including exclusive rights
of use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufacture the article or articles shown therein,
such permission to be granted only by written authorization signed by an officer or other authorized agent of Systems,Inc. thereof.
MATERIAL
STOCK NO.
INSTALLATION
OVERVIEW VIEW 2
Anchor pit floor mounting plate (minimum 3/8” x
20”W x 8”D, Part #9414-0056, Figure 10) with four
(4) 3/4” x 5-1/4” min. wedge anchors. Weld mounting
plate to curb steel and back plate of Stop-Tite with
a continuous 1/4” fillet weld. Anchor back plate of
Stop-Tite to dock face with a minimum of four (4) 3/4”
x 5-1/4” min. wedge anchors (Kit #2103-0003). See
Figure 11.
Note:
Trim or cut leveler front frame member as
shown in Figure 12 when necessary to allow for pit
floor mounting plate.
INSTALLATION
TOLERANCES
(UNLESS OTHERWISE NOTED)
FRACTIONAL:
1/32"
DECIMAL:
.00 =
.01"
.000 =
.005"
ANGULAR:
1
DRAWN BY
CHECKED BY
DRAWING NO.
DATE
BDK
1/27/2020
S Y S T E M S
L o a d i n g D o c k E q u i p m e n t
P O W E R A M P
M C G U I R E
D L M
This print is the property of Systems, LLC and represents a proprietary article in which Systems, LLC retains any and all patent and other rights, including exclusive rights
of use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufacture the article or articles shown therein,
such permission to be granted only by written authorization signed by an officer or other authorized agent of Systems, LLC thereof.
MATERIAL
STOCK NO.
INSTALLATION
OVERVIEW VIEW 2
REV A - ECN 18-066
If < 24”
Pit Floor
Mounting Plate
TOLERANCES
(UNLESS OTHERWISE NOTED)
FRACTIONAL:
1/32"
DECIMAL:
.00 =
.01"
.000 =
.005"
ANGULAR:
1
DRAWN BY
CHECKED BY
DRAWING NO.
DATE
BDK
1/22/2020
S Y S T E M S
L o a d i n g D o c k E q u i p m e n t
P O W E R A M P
M C G U I R E
D L M
This print is the property of Systems, LLC and represents a proprietary article in which Systems, LLC retains any and all patent and other rights, including exclusive rights
of use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufacture the article or articles shown therein,
such permission to be granted only by written authorization signed by an officer or other authorized agent of Systems, LLC thereof.
MATERIAL
STOCK NO.
9415-0062
FINAL ASM - PSTOP/STOPTITE 2018
REV A - ECN 18-066
If <24”
Trim frame here
Figure 11
Figure 12
Figure 10