&+(&.,1*7+(&+520(3/$7('3$576
Inspect the chrome-plated parts of the machine (cylinders) and make sure that they are not scored
or damaged.
&+(&.,1*7+(&283/(52,/
To check the level of the oil in the coupler make sure
WKDWWKHPDFKLQHLVRQDÀDWOHYHOVXUIDFHZLWKWKH
HQJLQHRIIIRUDWOHDVW¿YHPLQXWHV
•
Unscrew the cap (A) and check the dipstick to
make sure the oil is between the MAX and MIN
marks;
•
If the coupler is around the MIN mark, top up
again using the hole of the cap (A) until the level
is back in the range between MIN and MAX.
•
Tighten the cap (A).
Consult the table in section 9.4 for the choice of oil to
choose. You are advised to check the oil level in the
coupler every
500 hours.
.
&+$1*,1*7+(2,/,17+(&283/(5
To change the oil in the coupler, make sure that the
PDFKLQHLVRQDÀDWOHYHOVXUIDFHZLWKWKHHQJLQHRII
IRUDWOHDVW¿YHPLQXWHV
•
Unscrew the cap (A).
•
8QGRWKHGUDLQDJHSOXJ%DQGOHWWKHRLOÀRZRXW
LQWRDVXI¿FLHQWO\ODUJHUHFHSWDFOHWRIDFLOLWDWHWKH
drainage operation you should work while the oil
is warm;
•
Wait for a few minutes until all the oil has run out
then screw the plug (B) back;
•
5H¿OOWKHFRXSOHUZLWK
1.4 litres
of the appropriate
oil (see section 9.4.1.) through the hole of the
cap (A);
•
Screw up the cap (A).
7KH¿UVWRLOFKDQJHPXVWEHGRQHZKHQWKH¿UVW
50 duty hours
have elapsed while subsequent changes
must be done every
1000 hours
.
$
$
%
117