3--2
©
2012 Mobile Climate Control
T-353 Rev. 01/2013
Table 3-1 General System Troubleshooting Procedures - Continued
INDICATION -
TROUBLE
POSSIBLE CAUSES
REFERENCE
SECTION
3.4
Abnormal Noise Or Vibrations - Continued
Condenser or evaporator fans
Loose mounting hardware
Defective bearings
Blade interference
Blade missing or broken
Check/Tighten
Replace
Check
Check/Replace
3.5
No Evaporator Air Flow Or Restricted Air Flow
Air flow through coil blocked
Coil frosted over
Dirty coil
Dirty filter
Defrost coil
Clean
Clean/Replace
No or partial evaporator air flow
Motor(s) defective
Motor brushes defective
Evaporator fan loose or defective
Fan damaged
Return air filter dirty
Icing of coil
Fan relay(s) defective
Safety device open
Fan rotation incorrect
Repair/Replace
Replace
Repair/Replace
Repair/Replace
Clean/Replace
Clean/Defrost
Check/Replace
1.5
Check
3.6
Expansion Valve Malfunction
Low suction pressure with high super
heat
Low refrigerant charge
Wax, oil or dirt plugging valve orifice
Ice formation at valve seat
Power assembly failure
Loss of bulb charge
Broken capillary tube
4.7
Check
4.6
Replace
Replace
4.14
Low superheat and liquid slugging in
the compressor
Bulb is loose or not installed.
Superheat setting too low
Ice or other foreign material holding valve open
4.14
4.14
Side to side temperature difference
(Warm Coil)
Wax, oil or dirt plugging valve orifice
Ice formation at valve seat
Power assembly failure
Loss of bulb charge
Broken capillary
Check
4.6
Replace
Replace
4.14
3.7
Heating Malfunction
Insufficient heating
Dirty or plugged heater core
Coolant solenoid valve(s) malfunctioning or plugged
Low coolant level
Strainer(s) plugged
Hand valve(s) closed
Water pumps defective
Auxiliary Heater malfunctioning.
Clean
Check/Replace
Check
Clean
Open
Repair/Replace
Repair/Replace
No Heating
Coolant solenoid valve(s) malfunctioning or plugged
Controller malfunction
Pump(s) malfunctioning
Safety device open
Check/Replace
Replace
Repair/Replace
1.5
Continuous Heating
Coolant solenoid valve stuck open
4.11
Содержание 68AC430-100
Страница 1: ...OPERATION SERVICE for 68AC430 100 REV 01 2013 T 353 Manual T 353 2012 Mobile Climate Control...
Страница 30: ...5 2 2012 Mobile Climate Control T 353 Rev 01 2013 98 67037 00 Figure 5 2 Evaporator Motors...
Страница 31: ...5 3 2012 Mobile Climate Control T 353 Rev 01 2013 98 67037 00 Figure 5 3 Condenser Motors...
Страница 32: ...5 4 2012 Mobile Climate Control T 353 Rev 01 2013 98 67037 00 Figure 5 4 BT324 Controls With 1 Compressor...
Страница 33: ...5 5 2012 Mobile Climate Control T 353 Rev 01 2013 98 67037 00 Figure 5 5 BT324 Control Circuit...
Страница 34: ...5 6 2012 Mobile Climate Control T 353 Rev 01 2013 98 67037 00 Figure 5 6 AC430 With BT324 Control...