background image

 

 

                                                        User’s manual

 

SEEDER MONITOR MCK 800 

 
 
 

 

 

This product complies with EMC requirements as defined by  

Directives 2004/108/CE and successive modifications  

in accordance with standard EN ISO 14982 applied 

 

 
 
 

Manufacturer 

: MC elettronica S.r.l. 

Address 

: Via E. Fermi, 450/486  

 Fiesso Umbertiano (ROVIGO) – ITALY 

  Tel. +39 0425 754713      Fax  +39 0425 741130 
  E-mail: [email protected] 

  Internet: www.mcelettronica.it 

 

 
 

Manual code  

: 2611-EN 

Issued 

: February 2001 

Edition 

: November 2013 

 

MC elettronica S.r.l.

 is not obliged to give notice of any further modifications of the product.  

The information given in this manual does not allow unauthorized personnel to tamper the product 
in any way.  The guarantee on the equipment will no longer be valid if tampering should be 
detected. 

 
 
 
 

© Copyright MC elettronica  2013

 

 
 

Содержание MCK 800

Страница 1: ...MCK 800 COMPUTER FOR PRECISION SEED DRILLS NR 2611 EN REV 1 EN USER S MANUAL...

Страница 2: ...ALY Tel 39 0425 754713 Fax 39 0425 741130 E mail mcstaff mcelettronica it Internet www mcelettronica it Manual code 2611 EN Issued February 2001 Edition November 2013 MC elettronica S r l is not oblig...

Страница 3: ...ter pulses 100 metres 16 6 2 1 Practical example for calculating the C parameter to be programmed 17 6 3 Automatic calibration of C parameter 18 6 4 How to set the rows alarm sensitivity 18 6 5 How to...

Страница 4: ...of the equipment After buying the instrument read the manual carefully and refer to it any time you have doubts on how to use the equipment or when you have to carry out maintenance operations Keep t...

Страница 5: ...act of God lightning floods fire or other causes which do not depend from MC elettronica Repairs under guarantee which must be carried out in the laboratories of our authorized centres are entirely f...

Страница 6: ...peration of the file indicating the LCD by horizontal bars any abnormality of sowing During the working cycle the following data are displayed and controlled the width width PROG the working area tota...

Страница 7: ...User s manual SEEDER MONITOR MCK 800 7 2 1 How to install the system 2 1 1 Wiring attachments MCK 800 Figure 1 Wiring attachments VEL 1 2 3 4 5 6 7 8 POWER CABLE PHOTOCELLS SPEED SENSOR B D F...

Страница 8: ...to install the speed sensor D 18 cod 481 You can install the speed sensor cod 481 anywhere there is a mechanic movement in the wheel front or rear wheel of the agricultural vehicle machine or by makin...

Страница 9: ...s distribute the photocells cables on the seed drill air pipes respecting the row numeration Figure 2 fix the junction box A at the centre of the seed drill with some clamps held to the machine instal...

Страница 10: ...User s manual SEEDER MONITOR MCK 800 10 Figura 2 How to install photocells Figure 3 Example of installation on the pipe cod 10FOT 4RSTES 0FOT 4RSTIN Clamps 2 leds transmitter 3 leds receiver...

Страница 11: ...nual SEEDER MONITOR MCK 800 11 Figura 4 Example of installation on the sowing element cod 4228 and cod 10FOT SEMIMINUTI 0001 Optical elements Clamps Amplifier for photocell Electric cable from the jun...

Страница 12: ...01 to 999 9 ha during the programming phase it increases the displayed value B WIDTH PROG key it allows the operator to display and change the working width C ha TOTAL e key it shows the total area w...

Страница 13: ...EM 001 Cable 4 rows x 80 cm CAB SEM 002 Cable 6 rows x 80 cm CAB SEM 003 Cable 8 rows x 80 cm NOTE cables must be ordered according to the type of seed drill used the following data are required while...

Страница 14: ...cture 2 To reset working hours hold down any key for about 3 seconds while the display visualizes working hours after the initial test operated at the switching on After working hours the monitor disp...

Страница 15: ...rts flashing on the display Keeping width PROG key pressed hold down also key see ref A to increase or key ref C to decrease the displayed value until the desired value is obtained expressed in metres...

Страница 16: ...them pressed until the display shows the current parameter value preceded by letter C flashing then release keys Press key ref A to increase or key ref C to decrease the displayed value until the desi...

Страница 17: ...ons for our example let s say 30 then stop the machine end point Figure 5 ref B to obtain highest precision of setting you ll need to go at least 50 meters measure the distance from the starting point...

Страница 18: ...h PROG key ref B The impulses obtained will be automatically programmed in C parameter 6 4 How to set the rows alarm sensitivity To program the rows alarm sensitivity values from 1 to 20 the monitor m...

Страница 19: ...ioning of the photocells as follows Simulated test With one of your fingers or with a small object pass in front of each photocell if the photocell is correctly connected it will send impulses to the...

Страница 20: ...the instrument with a wet cloth and mild detergent to avoid erasing the serigraphs on the panel Warning Do not use pressure water jets Do not use abrasive products solvents or alcohol Do not press on...

Страница 21: ...Mechanic vibrations resistance 2 G Functioning conditions Room temperature 20 C 75 C Weather conditions Relative humidity 90 Transport and storage Temperature 25 C 85 C 8 2 Technical data accessories...

Страница 22: ...PN NO Max working frequency 200 Hz Working temperature 25 C 70 C Max operation distance 40 80 mm Pickup angle range 25 Protection degree IP 68 8 2 4 Cables cod CAB SEM 001 CAB SEM 002 CAB SEM 003 Main...

Страница 23: ...Printed in Italy SEEDER MONITOR MCK 800 NOTE...

Страница 24: ...Printed in Italy www mcelettronica it Electronic equipments for agricultural earth moving industrial machines...

Отзывы: