24
Installation and use
SEEDER MAT MCK 2500 SX
5.4 Automatic calibration of the “C” parameter (recommended!)
The automatic calibration for parameter “C” is carried out by covering an established
distance of 100 meters, following this procedure:
with the computer turned on, press the
M.
key more than once, until the
second left arrow on the display appears;
simultaneously press the
and
keys; <0> will appear on the computer;
cover the 10 meters; the impulses counted (1..2..3..) will appear on the display.
Once the 100 meters are covered, confirm by using the
key: the
computer will automatically memorize the number of impulses detected.
!
NOTE:
We recommend that this procedure be performed at least 2 consecutive
times, verifying that the value detected is always the same,
1 impulse.
If the difference is greater, this means that the speed inductive sensor is
NOT positioned correctly, therefore, it must be repositioned.