mbp KS 2300 Скачать руководство пользователя страница 10

7

SOLUTION

Remove siphon tube and feel lower ball check
to be sure it is free to move off it is seat. Place
full  cup  of  paint  thinner  over  end  of  fluid
section and turn on pump.

Remove and clean.
Hold gun trigger in open position and run unit
about 10 seconds until  air is purged. Check
for  siphon  tube leak.

Replace.
Prime pump with compatible solvent. Bring up
to  pressure,  carefully  remove  pump  from
solvent container and immerse inlet tube into
heavy material to be sprayed. With nozzle tip
removed  trigger  gun  until  heavy  material
appears at gun.
Replace nozzle tip and you are ready to spray.

Remove and clean.
Check connection and seal.
Relieve pressure, remove tip and clean.

Adjust to increase pressure.

Clean or temporaly remove.
Replace or clean.

Hold  gun  trigger  in  open  position  and  run
about 10 seconds until airs is purged.

Replace.
Replace.
With gun trigger closed, allow unit to pump
up  to  pressure  and  shut  off  if  pump
momentarily starts, internal leak is indicated
and fluid section rebuild is necesary.

CAUSE

Dried  out  piston  packings.
Stuck valve balls.

Pump inlet screen plugged.
Air in pump or hose

Packings worn.
Fluid too viscous.

Siphon tube clogged.
Siphon tube air leak.
Clogged tip.

Pressure  adjusting  knob  not
properly set.
Pump inlet strainer dirty.
Valve  balls  or  seats  worn  or
dirty.
Air in pump or hose.

Packings worn.
Worn spray tip.
Internal leakage.

TROUBLE

Unit will not
prime

Unit will not
build or
maintain
pressure.

TROUBLESHOOTING    CHART

8

CAUSE

Fuid leak.

Fluid too viscous.

Too large a spray tip.

Worn packing.

Upper packings worn.

Piston rod worn.

Too large a tip size.
Pressure adjustment wrong.
Insufficient fluid delivery.

Fuid too viscous.

Pressure adjustment low.
Improper voltage supply.

Excessive pressure.

Excesive extention cord length
or improper wire gauge.

TROUBLE

Unit will not
build or
maintain
pressure.

Fuid leakage
out relief hole
at  pressure
control.

Fluid leakage
at upper end
of fluid
section.

Bad spray
pattern.

Unit lacks
power.

Blown fuses
at pump.

SOLUTION

Check for external leaks including hydraulic
fittings  attached  to  pressure  control
housing.

Consult manufacturers recommendations on
paint container label.

Change tip.

Repack or replace transducer.

Relieve pressure and tighten packing take
up nut or replace packings.

Replace.

Change to a smaller tip size.
Adjust pressure control knob.
Clean all straines and filters in system.

Add  solvent  to  fluid  according  to
manufacturer’s recommendations.

Increase.
Reconnect input voltage accordingly.

Have Service  Center  recalibrate the pressure
control.

Use 3x1,5 mm. section wire or larger up to
maximum of 50 meters. For additional lenght,
more airless hose may be used.

Содержание KS 2300

Страница 1: ...ed to the amount of the original purchase price paid for the unit minus a reasonable deduction for the time the unit has been in service It is the responsibility of the purchaser under this warranty t...

Страница 2: ...uinas Machinery Directive 2006 42 EC and 94 9 ECAtex Directive APROBADO POR APPROVED BY AITOR ORTIZ FECHA DATE MBP S L figura inscrita en el Registro Industrial del Pa s Vasco con el N 01 8030 y cumpl...

Страница 3: ...mponents Safety warnings Operating instructions Cleaning Troubleshooting chart Parts drawing list Wiring diagram Pressure control assy Shutdown and care Standard spray tips Accesories 1 3 5 6 7 9 11 1...

Страница 4: ...HP FILTER SCREEN G 100 20 60 MESH G 100 05 100 MESH G 100 21 200 MESH REF GR 70 70 70 MESH REF GR 71 20 120 MESH SIEVE REF REF REF ACCESORIES TIP EXTENSIONS 90cms 30cms J 275 J 272 J 271 AIRLESS GUN...

Страница 5: ...Flush thesprayer at the end of each work dayand fill it with mineral spirits to helpprevent pumpcorrosion and freezing 100 150 200 250 300 350 100 150 200 250 300 350 100 150 200 250 300 350 100 150 2...

Страница 6: ...trate your skin get emergencymedical care at once Do not treat as a simple cut Tell the doctor exactlywhat fluid was injected All chemicals used in the pump must be compatible with the wetted parts of...

Страница 7: ...d Unplug the power supplycord No 14 Disengage the gun safety latch Hold a metal part of the gun to the side of a grounded metal pail and trigger thegunto relievepressure Engagethegun safetylatch Open...

Страница 8: ...m the valve close it Then disengage the gun safetylatch and proceed as in point 7 Check all fluid connections for leaks Ifanyare found followthe pressure relief beforetighteningconnections Install the...

Страница 9: ...tion tube from the pail Disengage the gun safety latch and trigger the gun to force solvent from the hose Do not let the pump rundryformorethan 15secondsto avoid damagingthepumppackings Then follow th...

Страница 10: ...not properly set Pump inlet strainer dirty Valve balls or seats worn or dirty Air in pump or hose Packings worn Worn spray tip Internal leakage TROUBLE Unit will not prime Unit will not build or maint...