Initial configuration | Page 47
of 90
10.3 Initial configuration via the web interface of the mbNET.mini
Connect one the mbNET.mini to the power supply.
Connect the mbNET.mini via one of the LAN interfaces to the Ethernet interface on your configuration PC.
A D V I C E
The configuration PC and the mbNET.mini must be in the IP address range (192.168.0.X).
For this purpose, where necessary, carry out the following settings on your computer:
The mbNET.mini is shipped with the IP address
192.168.0.100. You must therefore assign the same
address range to your computer. This applies for the IP
address as well as for the subnet mask.
To do this, open the properties for your LAN connec-
tion. You can set your computer’s IP address under the
properties for the Internet protocol (TCP/IP).
Your computer's IP address must be in the ad-
dress range “192.168.0.X”, the subnet mask must be
identical to that of the mbNET.mini (255.255.255.0).
You must enter the IP address of the mbNET.mini
(192.168.0.253) as the default gateway and as the pre-
ferred DNS server.
Default settings for mbNET.mini
IP address
192.168.0.100
Subnet mask
255.255.255.0
Login
admin
Password
(no password required)
A D V I C E
Change at the next opportunity unconditionally and without delay, the default login information!
Open your browser and enter the mbNET.mini's re-
quired IP address (192.168.0.100) in the address line.
Please enter the following details to log into the mb-
NET.mini:
Username:
admin
Password:
(no password required)
10.3.1
Firststart
After the device login you will be guided step by step through the "First Start" menu.
In the language selection of the menu header, you can choose between German and English.
The
Help
button provides access to the device online help.
Internet
(all devices)