background image

 

Page 

14

 of 

24

 

 

IMPORTANT NOTICE 

WARNING:

 When properly installed and operated this appliance should only emit 

fumes during fuelling and de-ashing. The stove is designed to be operated only with 
the doors shut. To prevent fume spillage only open the doors for ignition, refuelling 
and cleaning. Persistent fume emission is dangerous and in certain circumstances 
could be fatal. It should not be tolerated. If you experience heavy or persistent fume 
emission, follow the procedure below: 

1.

 

Open all windows or doors to ventilate the area. 

2.

 

Extinguish the fire and if safe to do so, remove fuel from the appliance. 

3.

 

Check for blockages in the appliance and clear if possible. Particular 
attention should be paid to the baffle plate which should be inspected for 
any accumulated soot and products of combustion regularly. If excessive 
amounts are present, the baffle plate needs removed and cleaned. 

4.

 

Have the chimney checked by a professional person for any sign of blockage. 

5.

 

Do not attempt to relight the appliance until the source of the blockage has 
been determined and cleared. 

6.

 

Seek professional opinion on the cause of the blockage if in any doubt. 

 
You may also detect a smell from the appliance on initial lighting while the paint 
cures. Stove paint must be cured on the surface of an appliance. During the first few 
hours of burning, there will be some fumes / smoke as the paint cures. When the 
body of the appliance is properly heated, it usually takes about an hour or so after 
that to bake / cure the paint. It is recommended to ventilate the room well by 
opening windows / doors during this time and where possible, leave the room. 

In the event of a chimney fire, immediately close the door and move the air wash to 
the closed position. Call for assistance from fire service. A chimney fire can cause 
significant damage to the chimney construction and must be assessed by a 
professional before relighting your appliance. 

Never burn plastics, household waste or liquids in your stove. 

Содержание Glencara

Страница 1: ...y Stove Range Eco design Compliant Operation and Installation Manual Glencara Ripley 4kW MZEDGCMF4 Glencara Ripley 5kW MZEDGCMF5 Glencara Ripley 8kW MZEDGCMF8 Version 2 09 06 2021 PLEASE RETAIN FOR FU...

Страница 2: ...list by Scottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 Similarly In Northern Ireland appliances are exempted by publication on a list by the Department of Agriculture...

Страница 3: ...you can t wait to get started but please read this manual thoroughly You ll learn the ins and outs of using your stove and we promise you you ll hit the ground running We d like to thank you for supp...

Страница 4: ...ork Hetas Information on Relevant Building Regulations Links to your specific local building regulations are also accessible through here https www hetas co uk consumer regulations Approved Document J...

Страница 5: ...earance above and in front of the appliance to provide sufficient space for heat to dissipate to room space See below for suggested distance to combustible materials Distance to combustibles Front Sid...

Страница 6: ...important that the flue or chimney to which this appliance is to be connected has been checked by a competent person to ensure its suitability and that it will work safely The chimney or flue and inst...

Страница 7: ...50mm pipe 450mm minimum clearance to wooden beam HEARTH CONSTRUCTION Hearths should be constructed of suitably robust materials and to appropriate dimensions such that in normal use they prevent combu...

Страница 8: ...here the embers are glowing 3 Add your fuel of choice and control the stove as advised Burn small loads initially in your new appliance before full fires are used to allow paint fitting cement to cure...

Страница 9: ...lp achieve the optimum temperature for clean combustion See bottom of page 17 for optimum flue temperature for the relevant fuels Recommended Fuels Split and dried logs properly seasoned with less tha...

Страница 10: ...vent excessive smoke Refuelling Coal 1 De ash the fire bed using the riddle control on the left of the stove 2 Fully open the left primary air control 3 Open door add coal close door 4 Adjust the prim...

Страница 11: ...ficult to light or slow to heat up Operation with door left open Operation with the door open can cause excess smoke The appliance must not be operated with the appliance door left open except as dire...

Страница 12: ...trols Excessive draft Install draft stabiliser damper Insufficient Seal Check condition of rope seal around glass Smokes upon initial lighting Cold flue pipe Burn firelighters small fuel loads to preh...

Страница 13: ...Page 13 of 24 Low heat output Poor quality fuel Use recommended fuels Insufficient Seal Check condition of rope seal around glass...

Страница 14: ...4 Have the chimney checked by a professional person for any sign of blockage 5 Do not attempt to relight the appliance until the source of the blockage has been determined and cleared 6 Seek professi...

Страница 15: ...urely Baffle plate Particular attention should be paid to the baffle plate s which should be regularly inspected for any accumulated soot and products of combustion If a medium to excessive amount is...

Страница 16: ...hen unit is hot Flue Chimney cleaning Please ensure the flue is swept as instructed Blockages or build ups within the flue can cause loss of performance damage to the product and harm to the surroundi...

Страница 17: ...h Anthracite Output kW nominal 4 1 4 5 5 0 4 9 8 4 8 0 Efficiency 75 4 79 2 75 6 86 5 79 0 79 6 CO Emissions at 13 O2 vol 0 10 0 09 0 12 0 10 0 10 0 08 NOx Emissions at 13 O2 mg m0 3 91 140 102 111 80...

Страница 18: ...m Depth m m Weig ht kg Collar mm Maximu m log length mm Glencara Rip ley 4kW 487mm 380mm 292mm 59 5 5 125m m 250mm x 100mm Glencara Rip ley 5kW 487mm 380mm 342mm 68 5 125m m 250mm x 100mm Glencara Ri...

Страница 19: ...Page 19 of 24 7 PRODUCT DRAWINGS Glencara Ripley 4kW Glencara Ripley 5kW...

Страница 20: ...Page 20 of 24 Glencara Ripley 8kW...

Страница 21: ...Page 21 of 24 EXPLODED DIAGRAM...

Страница 22: ...Baffle brick 7 1 Flue collar 8 1 Baffle brick fixing bar 9 2 Blanking Plate 10 1 Outside air back cover 11 1 Ashpan 12 1 Ashpan tool 13 1 Bottom grate 14 1 Bottom grate support 15 1 Riddling bar 16 1...

Страница 23: ...ght problems and chimney defects Damage caused by over firing Damage resulting from the use of unsuitable fuel Unauthorised modifications misuse neglect abuse excessive wear and tear and the use of no...

Страница 24: ...BE ABLE TO PROCESS YOUR CLAIM Customer name Customer Address Post Code Date Contact Number s Retailer Name Retailer Contact Date of Purchase Type of fuel used Problem reported Comments Date of Instal...

Отзывы: