Basic Climate Control
A/C System
Multiflow Condenser with Sub-cooler
•
The multiflow condenser with a sub-cooler sends the refrigerant to the receiver / drier
and then back into the lower sub-cooling portion of the condenser. Incorporating the
receiver / drier into the condenser ensures that at this last sub-cooling stage (no.4 in the
illustration) only liquid refrigerant is being cooled.
NOTE:
Depending on the model the receiver / drier cannot be replaced separately, i.e. the
condenser must be replaced as a unit.
L1005_008
1 Condenser
4 Sub-Cooling
section
2 Refrigerant
flow
5 Receiver/Drier
3 Cooling
section
Curriculum Training