6-6
6-2-5 Foundation
Work
CAUTION
l
If the machine has to be installed near vibration-generating equipment, it is necessary to
take appropriate measures such as providing a vibration insulation pit around the machine.
l
If the soil is weak, reinforce it by driving piles to avoid settling and subsidence of the soil
after the installation of a machine.
For machine installation, select a flat place; avoid places subject to direct sunlight, humid places,
and places near vibration generation equipment. Although required foundation work will vary
according to soil conditions, it is necessary to compact the ground well or pour concrete to avoid
settlement or inclination of the soil after machine installation.
•
Foundation
parts
Quantity
Part Name
Part No.
Type B (standard specifications)
Jack bolt
34710400020
8
Block
44856102010
5
Block
45576105340
3
Hex. nut
M38
34710400030
8
Collar hex head cap screws
M6
×
10
A15B06X100
5
Hex. nut
M16
A40JJ00M160
5
Washer
M16
A41JJ00M160
5
Anchor bolt
34946110050
5
Collar
44946110060
5
Plate
44966111010
2
Bolt
44966111020
2