7
Electrical Requirements - Canada Only
WARNING
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
It is your responsibility
■
To contact a qualified electrical installer.
■
To be sure that the electrical connection is adequate and in conformance with the
Canadian Electrical Code, C22.1-latest edition and all local codes. A copy of the above
codes standard may be obtained from: Canadian Standards Association, 178 Rexdale
Blvd., Toronto, ON M9W 1R3 CANADA.
■
To supply the required 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical
supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. Connect to an individual branch circuit.
■
This dryer is equipped with a CSA International Certified Power Cord intended to be
plugged into a standard 14-30R wall receptacle. The cord is 5 ft (1.52 m) in length. Be
sure wall receptacle is within reach of dryer’s final location.
4-wire receptacle 14-30R
■
Do not use an extension cord.
If you are using a replacement power supply cord, it is recommended that you use Power
Supply Cord Replacement Part Number 3394208. For further information, please reference
the service numbers located in the “Assistance or Service” section
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
.