Troubleshooting

Will Not Run
Will not start or run:

• All wires are hooked up to their corresponding

terminals. 

• Dryer is plugged in. 
• Blown fuse or circuit breaker. 
• Door switch functional...door closed. Check for

diagnostic code 3. 

• Start/Pause switch functional.
• Control Board operational.
• Drive motor functional.
• Check motor Winding Resistance: 2.88Ω between Pin

#3 and 4, 3.5Ω between Pin #4 and 5 are normal
status. (±5% 25°C basis)  

Motor runs/ tumbler will not turn:

• Belt off or broken/damaged.
• Idler tension spring too weak or stretched.
• Idler pulley jammed or stuck.

Runs a few minutes and then stops:

• Lint buildup around drive motor.
• Low voltage present.
• Blower impeller blocked in blower housing.
• Drive motor - start switch contacts stuck closed.

Blows fuses or trips circuit breaker:

• The amperage readings are at 240 volts. One line

will be 24 amps and the other line will be 21 amps.
The neutral line will be at 3 amps. If the above
amperages are present, then the house wiring,
fuse box or circuit breaker should be suspect.

• Shorted heating element to housing.
• Incorrect wiring or a wire shorting to ground.
• Drive motor winding shorting to ground.

Gas Models

• During ignition the dryer will draw 8 amps. With the

burner ON, the dryer will draw 4.5 amps. If the dryer is
drawing amperages above this, then the house wiring,
fuse box or circuit breaker is suspected to be at fault.

• Igniter harness loose and shorted to base.
• Incorrect wiring or wire shorted to ground.
• Drive motor winding shorting to ground.

Will Not Dry
Will not heat (motor runs):

• Open heating element.
• Hi-Limit trips easily or is open.
• Regulating thermostat trips easily or is open.
• Membrane switch open.
• Check Thermistor.

Will Not Dry(Gas Models)
Poor Gas lgnition

When the dryer is operated on a heat setting, the igniter
should be energized and burner shall fire within 45
seconds at 120 VAC. The failure of a component in this
system will usually be indicated by one of three
symptoms:

The igniter does not glow.

If the igniter does not heat up, remove power and using
an ohmmeter, check the following:
• Open flame sensor
• Open igniter
• Shorted booster coil
• Open wiring
• Bad motor switch (Neutral supply)
• No power from control (L1 supply)

Igniter glows - No gas ignition.

If the igniter heats up but the main burner flame is not
ignited, remove power and using an ohmmeter, check
the following:
• Open secondary coil
• Open holding coil
• Open wire harness
• Stuck flame sensor (Stuck closed)

The gas is ignited but the flame goes out.

If a normal ignition takes place and after a short while
the flame goes out, check for the following:
• Radiant sensor contacts opening prematurely
• Weak gas valve coil may open when stressed by higher

temperatures

• Weak Hi_Limit
• Poor venting
• Bad drum seals

Improper drying/clothes wrinkled/ rough
texture/long dry time:

• Lint filter is not clean.
• Restriction in exhaust.
• Outside exhaust hood damper door stuck closed.
• Exhaust too long, too many elbows, flex ductwork

installed.

• Poor makeup air available for the dryer.
• Incorrect tumbler speed. Tumbler belt slipping.
• Blower impeller bound; check for foreign material

in blower area.

• Customer overloading dryer.
• Check clothing labels for fabric content and cycle

selected.

• Clothes too wet due to insufficient spin out by

washer.

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless
testing requires power.

Содержание NED7200TW

Страница 1: ...pacity cu ft Cycles Controls Dryness Control Intellidry Sensor Outboarded Adj Degree of Dryness Less Dry Normal Dry More Dry Temperature Settings not inc Air Fluff Fabric Selections Regular Cycle Wrinkle Control Cycle w Cool Down Delicates Gabric Selection Sound Silencing Package Time Dry Air Fluff Wrinkle Release Wrinkle Prevent Tumbler End of Cycle Chime Drum Light Extra Large Reversible Door Op...

Страница 2: ...en Regulating thermostat trips easily or is open Membrane switch open Check Thermistor Will Not Dry Gas Models Poor Gas lgnition When the dryer is operated on a heat setting the igniter should be energized and burner shall fire within 45 seconds at 120 VAC The failure of a component in this system will usually be indicated by one of three symptoms The igniter does not glow If the igniter does not ...

Страница 3: ...ice Mode or repeat the Chime and Temperature sequence Diagnostic Tests The following table lists the various tests available while in the Service Mode Before advancing to the temperature in next test the current test running must be terminated Press the following keys to access System Check Mode While in Service Mode pressing the Time and Wrinkle Prevent keys for 3 seconds will put the dryer into ...

Страница 4: ...rvice Mode and pressing Wrinkle Prevent A d will be displayed Rotate the Cycle Selector Knob in either direction to step through the list of codes one code at a time Once an initial direction is selected by the user either Clockwise or Counterclockwise subsequent movements of the knob in the same direction will show older codes If the user changes direction and turns the knob in the opposite direc...

Страница 5: ...tuck Run membrane pad check and replace console w membrane pad if necessary Display Description Trigger Action Taken tS Dryer Thermistor Short Sensed The Thermistor resistance is very low Check for Clogged lint screen Restricted vent system Check Thermistor resistance Check for diagnostic code 1 do Door Open Running the dryer with door open Check for Close the door and run the dryer Loose or open ...

Страница 6: ...Door switch button out Terminal COM NC 1 3 1Ω Terminal COM NO 1 2 Ω 2 Door switch button in Terminal COM NC 1 3 Ω Terminal COM NO 1 2 1Ω Belt Cut off S W Lever open Resistance value 1Ω Lever push Resistance value Ω Lamp resistance 80 100 Ω Violet gray Motor Electronic GAS Contacts WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless t...

Страница 7: ...ance across terminal indicates a closed switch Less than 1 ohm Centrifugal Switch Motor TH2 Hi Limit Gas Check across terminals 1 and 3 Booster Coil 550 ohms Check across terminals 1 and 2 Holding Coil 1350 ohms Check across terminals 2 and 3 Both coils in series 1900 ohmsCheck across terminals 4 and 5 Secondary Coil 1300 ohms Gas Valve Radiant Sensor Gas 230 180 F 110 82 C 25A HI limit ...

Страница 8: ...Input Blue Black wire on Heater Relay Sensor Bars Disconnect harness and test Pink wire Pin 4 to Orange wire Pin 5 Approx Ω without laundry Approx 190 Ω 10 with wet clothes Cycling Thermostat Disconnect harness and test Blue wire Pin 2 to Red wire Pin 6 Approx 10 K Ω at 25 C 77 F 120VAC Motor input Brown 1P on Motor relay White wire Sensor Bars temperature sensor check 6 1 CN3 CN6 MOTOR HEATER ...

Страница 9: ...W10162408 9 Wiring Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires power ...

Страница 10: ...W10162408 10 Wiring Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires power ...

Страница 11: ...ne du degré de séchage Less Dry séchage faible Normal Dry séchage normal More Dry séchage élevé Réglages de température sans Air Fluff air froid Sélections qualités des tissus Cycle Regular cycle normal Cycle Wrinkle Control sans froissage avec refroidissement Cycle Delicates délicats Ensemble de réduction du bruit Temps de séchage Air Fluff air froid Wrinkle Release désactiver sans froissage Prév...

Страница 12: ...stat de régulation se déclenche facilement ou est ouvert Le commutateur à membrane est ouvert Contrôler la thermistance Ne sèche pas modèles à gaz L allumage du gaz est faible Lorsque la sécheuse fonctionne en mode chaleur l allumeur doit être alimenté et le brûleur se met en marche dans les 45 secondes à une tension de 120 V c a Lorsqu un des composants du système est défectueux cela se manifeste...

Страница 13: ...service les données de la barre de contact du détecteur s affichent Désactivation du mode de service Pour quitter le mode de service appuyez sur la touche OFF ou répétez la séquence Chime et Temperature Essais de diagnostic Le tableau suivant présente les différents essais disponibles en mode de service Avant de passer à l essai suivant celui qui est en cours doit être terminé Appuyez sur les touc...

Страница 14: ... codes de diagnostic en activant le mode de service et en appuyant sur la touche Wrinkle Prevent La lettre d s affiche La rotation du sélecteur de cycle dans un sens ou l autre permet de parcourir la liste des codes un à la fois sans boucle Lorsque l utilisateur choisit un sens soit horaire ou antihoraire les déplacements subséquents du sélecteur dans le même sens permettent d afficher les anciens...

Страница 15: ...éant Code Description Déclencheur Mesure à prendre tS Court circuit de la thermistance de la sécheuse La résistance de la thermistance est très faible Vérifiez si le filtre à charpie est bouché si le système de ventilation est obstrué la résistance de la thermistance la présence du code de diagnostic 1 do La porte est ouverte Fonctionneme nt de la sécheuse avec la porte ouverte Vérifiez en fermant...

Страница 16: ...inférieure à 1 Ω Borne COM NO 1 2 Ω 2 Interrupteur de porte enclenché Marche Borne COM NC 1 3 Ω Borne COM NO 1 2 inférieure à 1 Ω Interrupteur d arrêt de la courroie levier ouvert Valeur de résistance inférieure à 1 Ω Levier enclenché Valeur de résistance Ω Résistance de la lampe de 80 100 Ω violet et gris Moteur électronique et gaz Éléments de contact AVERTISSEMENT Pour éviter tout risque d élect...

Страница 17: ... interrupteur est fermé Moins de 1 ohm Interrupteur centrifuge moteur Limite sugérieure TH2 gaz Vérifier aux bornes 1 et 3 bobine de démarrage 550 ohms Vérifier aux bornes 1 et 2 bobine de maintien 1 350 ohms Vérifier aux bornes 2 et 3 deux bobines en série 1 900 ohms Vérifier aux bornes 4 et 5 bobine secondaire 1 300 ohms Soupape de gaz Capteur d énergie radiante gaz INTERRUPTEUR ILLUSTRÉ EN POSI...

Страница 18: ...Débrancher le faisceau et effectuer une vérification entre la broche 4 du fil rose et la broche 5 du fil orange Approx Ω sans charge de vêtements Approx 190 Ω 10 avec des vêtements humides Thermostat à fonctionnement cyclique Débrancher le faisceau et effectuer une vérification entre la broche 2 du fil bleu et la broche 6 du fil rouge Approx 10 kilohms à 25 C 77 F 120 V c a Entrée de moteur Brun 1...

Страница 19: ...08 19 Schéma de câblage AVERTISSEMENT Pour éviter tout risque d électrocution de blessure ou de mort débranchez la sécheuse avant de la réparer à moins que l alimentation ne soit nécessaire à des fins d essai ...

Страница 20: ...08 20 Schéma de câblage AVERTISSEMENT Pour éviter tout risque d électrocution de blessure ou de mort débranchez la sécheuse avant de la réparer à moins que l alimentation ne soit nécessaire à des fins d essai ...