Maytag MLG34 Скачать руководство пользователя страница 8

8

Maytag Co.

113497 - 1

Installation Procedures ______________

Installation should be performed by competent professional
in accordance with local, state, and country codes.  In the
absence of these codes, the installation must conform to
applicable American National Standards: ANSI Z223.1-
LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA
NO. 70-LATEST EDITION (National Electrical Code) or in
Canada, the installation must conform to applicable Canadian
Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/
CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for
General Installation and Gas Plumbing) or Canadian
Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST
EDITION (for Electrical Connections).

Location Requirements ______________

Before installing the dryer, be sure the location conforms to
local codes and ordinances.  In the absence of such codes
or ordinances the location must conform with the National
Fuel Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada,
the installation must conform to applicable Canadian
Standards: CAN/CGA-B149.1-M91 (Natural Gas) or
CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for
General Installation and Gas Plumbing).

The dryer must be installed on a sound level floor capable of
supporting its weight.  Carpeting must be removed from the
floor area that the dryer is to rest on.

The dryer must not be installed or stored in an area where it
will be exposed to water and/or weather.

Provisions for adequate air supply must be provided as noted
in this manual (refer to Fresh Air Supply Requirements
section).

Clearance provisions must be made from combustible
construction as noted in this manual (refer to Dryer Enclosure
Requirements section).

Provisions must be made for adequate clearances for
servicing and for operation as noted in this manual (refer to
Dryer Enclosure Requirements section).

The dryer must be installed with a proper exhaust duct
connection to the outside as noted in this manual (refer to
Exhaust Requirements section).

The dryer must be located in an area where correct exhaust
venting can be achieved as noted in this manual (refer to
Exhaust Requirements section).

IMPORTANT:

 The dryer should be located where a

minimum amount of exhaust ducting will be necessary.

The dryer must be installed with adequate clearance for air
openings into the combustion chamber.

CAUTION: This dryer produces combustible lint and
must be exhausted to the outdoors.  Every 6 months,
inspect the exhaust ducting and remove any lint
buildup.

IMPORTANT:

 The dryer must be installed in a location/

environment, which the ambient temperature remains
between 40° F (4.44° C) and 130° F (54.44° C).

Unpacking/Setting Up ________________

Remove protective shipping material (i.e., plastic wrap and
optional shipping box) from the dryer.

Think safety when transporting and handling this dryer.

When handling this dryer during uncrating and/or installation,
keep in mind its weight and center of gravity.  Use of an
appliance hand truck with auxiliary wheel set is
recommended.  Use proper lifting techniques to avoid injury.
When in doubt, use help in handling heavy appliances.

IMPORTANT:

 Dryer must be transported and handled in an

upright position at all times.

The dryer can be moved to its final location while still attached
to the skid or with the skid removed.  To remove the skid
from the dryer, locate and remove the two bolts securing the
base of the dryer to the wooden skid.  One is located at the
center rear and the other is at the center front.

With the skid removed, use caution and assure all four
leveling legs are fully retracted if the dryer is to be slid into its
final position.

Leveling Dryer

The dryer is equipped with four leveling legs, one at each
corner of the base.  For optimum performance the dryer
should be level front-to-back and side-to-side.

Dryer Enclosure Requirements _______

Bulkheads and partitions should be made of noncombustible
material.

NOTE:

 Allowances must be made for opening the control

door.

A

The requirement to allow the door to open completely is 33-inches
(83.8 cm).

B

A minimum overhead clearance of 6-inches (15.24 cm) is required.

C Dryer should be positioned a minimum of 12-inches (30.48 cm) away from

the nearest obstruction.  24-inches (60.96 cm) is recommended for ease
of installation, maintenance, and service.

D 1/16” (1.5875 mm) minimum is required.

E

Flooring should be level or below dryer cabinet for ease of removing panels
during maintenance.

F

Dryers may be positioned sidewall to sidewall, however a 1/16”
(1.5875 mm) minimum allowance must be made for the opening and closing
of the control door, along with the removal of panels during maintenance.

Содержание MLG34

Страница 1: ...upplier AVERTISSEMENT Assurez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel toute bless...

Страница 2: ...___ SERIAL NUMBER S __________________________________________________________________________________ _________________________________________________________________________________________________...

Страница 3: ...t dry mop heads in the dryer Do not use dryer in the presence of dry cleaning fumes The dryers must not be installed or stored in an area where it will be exposed to water and or weather The wiring di...

Страница 4: ...m sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard A program should be established for the inspection and cle...

Страница 5: ...______________________________________ ____________________________________________________________ NOTES _____________________________________________________ ________________________________________...

Страница 6: ...R CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION PER POCKET 1 2 M N P T 3 8 M B S P T CE ONLY VOLTAGE AVAILABLE N A APPROXIMATE NET WEIGHT APPROXIMATE SHIPPING WEIGHT AIRFLOW PER POCKE...

Страница 7: ...113497 1 Maytag Co 7 Specifications _______________________________________________________________________...

Страница 8: ...necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combustible lint and must be exhausted to the outdoors Every 6 mo...

Страница 9: ...use of 90 turns be avoided use 30 and or 45 bends instead The radius of the elbows should preferably be 1 1 2 times the diameter of the duct All ductwork should be smooth inside with no projections fr...

Страница 10: ...uns the cross sectional area of the ductwork can only be increased to an extent When the ductwork approaches the maximum limits as noted in this manual a professional HVAC firm should be consulted for...

Страница 11: ...164 120 80 54 SQ CM 1058 774 2 516 1 348 4 MINIMUM ROUND DUCT DIAMETER IN 14 12 10 8 CM 35 56 30 48 25 4 20 32 Each pocket should be connected to an independently protected branch circuit The dryer mu...

Страница 12: ...e ONLY For others calculate verify correct breaker size according to appliance amp draw rating and type of breaker used SERVICE VOLTAGE PHASE WIRE SERVICE APPROX AMP DRAW CIRCUIT BREAKER 60 Hz 50 Hz 1...

Страница 13: ...____________________________________________________________ ____________________________________________________________ WARNING Fire or explosion could result due to failure of isolating or disconne...

Страница 14: ...nternal regulator disabled Information is per pocket tumbler Consult factory for elevations over 2 000 feet 610 meters for correct orifice size Heat Input Gas Consumption Orifice Injector Data For CE...

Страница 15: ...t all connections for leaks by brushing on a soapy water solution liquid detergent works well WARNING Never test for leaks with a flame Converting from One Family of Gas to Another ___________________...

Страница 16: ...the dryer and test for leaks IMPORTANT Never test for leaks with an open flame Use a soapy water solution or product intended for that purpose Regulated Gas Valve Refer to Gas Pressure Adjustment on...

Страница 17: ...e and the manometer The use of the spring mechanical type gauge is not recommended because they are very easily damaged and are not always accurate The preferred type of gauge is the manometer because...

Страница 18: ..._ IMPORTANT For more detailed information regarding the microprocessor controller computer refer to the microprocessor user s manual included with the dryer Coin Models Microprocessor Controller Compu...

Страница 19: ...quency of cleaning the lint screen can best be determined from experience at each location Weekly Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor area WARNIN...

Страница 20: ...2 Serial Number Allows the manufacturer to gather information on your particular dryer 3 Type of Heat This describes the type of heat for your particular dryer gas either natural gas or L P gas elect...

Страница 21: ..._____________________________________________ _________________________________________________________________________________________________________________________________ ________________________...

Страница 22: ...Part No 113497 1 12 10 10 0...

Отзывы: