IMPORTANT:

 No more than four dryers should be

connected to one main common duct.

The illustration below shows the minimum cross-sectional
area for multiple dryer round or square venting.  These figures
must be increased if the main duct run from the last dryer to
where it exhausts to the outdoors is longer than 12 feet (3.656
meters) or has more than one elbow in it.

Multiple Dryer Venting with 8-Inch (20.32 cm) Diameter

720 cfm (20.39 cmm) Exhaust Connections at Common Duct

NOTE 1

Opening from combustible materials must be 2-inches (5.08 cm)
larger than the duct (all the way around).  The duct must be centered
within this opening.

NOTE 2

Distance should be two times the diameter of the duct to the nearest
obstruction.

Electrical Information ________________

Electrical Requirements

All electrical connections must be made by a properly licensed
and competent electrician.  This is to ensure that the electrical
installation is adequate and conforms to local, state, and
national regulations or codes of the country of origin.  In the
absence of such codes, all electrical connections, materials,
and workmanship must conform to the applicable
requirements of the National Electrical Code ANSI/NFPA NO.
70-LATEST EDITION or in Canada, the Canadian Electrical
Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.

IMPORTANT:

 Failure to comply with these codes or

ordinances, and/or the requirements stipulated in this
manual can result in personal injury or component failure.

NOTE:

 Component failure due to improper installation will

void the warranty.

A = 8-inches (20.32 cm)
B = 12 feet (3.656 meters)

NUMBER OF DRYERS

4

3

2

1

MINIMUM CROSS-

SECTIONAL AREA

SQ IN

164

120

80

54

SQ CM

1058

774.2

516.1

348.4

MINIMUM ROUND
DUCT DIAMETER

IN

14

12

10

8

CM

35.56

30.48

25.4

20.32

Each pocket should be connected to an independently
protected branch circuit.  The dryer must be connected with
copper wire only.  Do not use aluminum wire, which could
cause a fire hazard.  The copper conductor wire/cable must
be of proper ampacity and insulation in accordance with
electric codes for making all service connections.

NOTE:

 The use of aluminum wire will void the warranty.

An individual ground circuit must be provided to each
pocket, do not daisy chain.

Component failure due to improper voltage application will
void the warranty.

The manufacturer reserves the right to make changes in
specifications at any time without notice or obligation.

IMPORTANT:

 A separate protected circuit must be

provided to each pocket.

The dryer must be connected to the electric supply shown
on the data label.  In the case of 208 VAC or 240 VAC, the
supply voltage must match the electric service
specifications of the data label exactly.

The wire size must be properly sized to handle the related
current.

!

 WARNING

208 VAC and 240 VAC are not the same.  Any damage
done to dryer components due to improper voltage
connections will automatically void the warranty.

!

 WARNING

(Gas Models Only – Export)

Dryers built for use with a voltage between 200 and
240 must verify the input voltage during installation.
If the nominal voltage is outside of the medium
tolerances shown on the diagram below, adjust the
autotransformers, located near the burner
assemblies.  To adjust the autotransformer wiring,
place the red wire on the appropriate tap (HIGH, MED,
LOW) of the autotransformer.  For additional wiring
details, refer to the electrical diagram located on the
inside of the control panel.

TERM

LINE VOLTAGE

50 Hz

60 Hz

HIGH

260
226

283
249

MED

239
208

260
230

LOW

217
189

236
208

Содержание MLG34

Страница 1: ...upplier AVERTISSEMENT Assurez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel toute bless...

Страница 2: ...___ SERIAL NUMBER S __________________________________________________________________________________ _________________________________________________________________________________________________...

Страница 3: ...t dry mop heads in the dryer Do not use dryer in the presence of dry cleaning fumes The dryers must not be installed or stored in an area where it will be exposed to water and or weather The wiring di...

Страница 4: ...m sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard A program should be established for the inspection and cle...

Страница 5: ...______________________________________ ____________________________________________________________ NOTES _____________________________________________________ ________________________________________...

Страница 6: ...R CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION PER POCKET 1 2 M N P T 3 8 M B S P T CE ONLY VOLTAGE AVAILABLE N A APPROXIMATE NET WEIGHT APPROXIMATE SHIPPING WEIGHT AIRFLOW PER POCKE...

Страница 7: ...113497 1 Maytag Co 7 Specifications _______________________________________________________________________...

Страница 8: ...necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combustible lint and must be exhausted to the outdoors Every 6 mo...

Страница 9: ...use of 90 turns be avoided use 30 and or 45 bends instead The radius of the elbows should preferably be 1 1 2 times the diameter of the duct All ductwork should be smooth inside with no projections fr...

Страница 10: ...uns the cross sectional area of the ductwork can only be increased to an extent When the ductwork approaches the maximum limits as noted in this manual a professional HVAC firm should be consulted for...

Страница 11: ...164 120 80 54 SQ CM 1058 774 2 516 1 348 4 MINIMUM ROUND DUCT DIAMETER IN 14 12 10 8 CM 35 56 30 48 25 4 20 32 Each pocket should be connected to an independently protected branch circuit The dryer mu...

Страница 12: ...e ONLY For others calculate verify correct breaker size according to appliance amp draw rating and type of breaker used SERVICE VOLTAGE PHASE WIRE SERVICE APPROX AMP DRAW CIRCUIT BREAKER 60 Hz 50 Hz 1...

Страница 13: ...____________________________________________________________ ____________________________________________________________ WARNING Fire or explosion could result due to failure of isolating or disconne...

Страница 14: ...nternal regulator disabled Information is per pocket tumbler Consult factory for elevations over 2 000 feet 610 meters for correct orifice size Heat Input Gas Consumption Orifice Injector Data For CE...

Страница 15: ...t all connections for leaks by brushing on a soapy water solution liquid detergent works well WARNING Never test for leaks with a flame Converting from One Family of Gas to Another ___________________...

Страница 16: ...the dryer and test for leaks IMPORTANT Never test for leaks with an open flame Use a soapy water solution or product intended for that purpose Regulated Gas Valve Refer to Gas Pressure Adjustment on...

Страница 17: ...e and the manometer The use of the spring mechanical type gauge is not recommended because they are very easily damaged and are not always accurate The preferred type of gauge is the manometer because...

Страница 18: ..._ IMPORTANT For more detailed information regarding the microprocessor controller computer refer to the microprocessor user s manual included with the dryer Coin Models Microprocessor Controller Compu...

Страница 19: ...quency of cleaning the lint screen can best be determined from experience at each location Weekly Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor area WARNIN...

Страница 20: ...2 Serial Number Allows the manufacturer to gather information on your particular dryer 3 Type of Heat This describes the type of heat for your particular dryer gas either natural gas or L P gas elect...

Страница 21: ..._____________________________________________ _________________________________________________________________________________________________________________________________ ________________________...

Страница 22: ...Part No 113497 1 12 10 10 0...

Отзывы: