Maytag MLG-45PDB Скачать руководство пользователя страница 3

113489- 3  (W10185535)

Maytag Co.

3

IMPORTANT SAFETY INSTRUCTIONS

WARNING: 

To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,

including the following:

SAVE THESE INSTRUCTIONS

Read all instructions before using the dryer.

Do not place items exposed to cooking oils in your
dryer.  Items contaminated with cooking oils may
contribute to a chemical reaction that could cause a
load to catch fire.

Do not dry articles that have been previously cleaned
in, washed in, soaked in, or spotted with gasoline,
dry-cleaning solvents, other flammable, or explosive
substances as they give off vapors that could ignite
or explode.

Do not allow children to play on or in the dryer.
Close supervision of children is necessary when the
dryer is used near children.

Before the dryer is removed from service or
discarded, remove the door to the drying
compartment.

Do not reach into the dryer if the drum is moving.

Do not install or store the dryer where it will be
exposed to the weather.

Do not tamper with controls.

Do not repair or replace any part of the dryer or
attempt any servicing unless specifically
recommended in this installation manual or in
published user-repair instructions that you
understand and have the skills to carry out.

Do not use fabric softeners or products to eliminate
static unless recommended by the manufacturer of
the fabric softener or product.

Do not use heat to dry articles containing foam
rubber or similarly textured rubber-like materials.

Clean lint screen every third load to fourth.

Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint,
dust, and dirt.

The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.

See installation instructions for grounding
requirements.

IMPORTANT: 

The gas installation must conform with local codes, or in the absence of local codes, with the National

Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.

In the State of Massachusetts, the following installation instructions apply:

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or
licensed by the State of Massachusetts.

If using a ball valve, it shall be a T-handle type.

A flexible gas connector, when used, must not exceed 3 feet.

WARNING: 

Gas leaks cannot always be detected by smell.

Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the “What to do if you smell gas” instructions.

Содержание MLG-45PDB

Страница 1: ...MLG 45PDB Installation Manual Stack Dryer Part No 113489 3 W10185535 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE...

Страница 2: ...to light any appliance Do not touch any electrical switch Do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s ph...

Страница 3: ...iminate static unless recommended by the manufacturer of the fabric softener or product Do not use heat to dry articles containing foam rubber or similarly textured rubber like materials Clean lint sc...

Страница 4: ...l entretien des commandes tiquetez tous les fils avant de les d brancher Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux WARNING The dryer must never be operated wit...

Страница 5: ...TAINER 8 16 DRYERS PER 48 53 TRUCK 25 27 VOLTAGE AVAILABLE 120 240V 1 2w 50 60 Hz APPROXIMATE NET WEIGHT 1 015 lb 460 40 kg APPROXIMATE SHIPPING WEIGHT 1 080 lb 489 88 kg AIRFLOW PER POCKET 60 Hz 600...

Страница 6: ...st be installed with adequate clearance for air openings into the combustion chamber IMPORTANT The dryer must be installed in a location environment which the ambient temperature remains between 40 F...

Страница 7: ...from the nearest obstruction 24 inches 60 96 cm is recommended for ease of installation maintenance and service D 1 16 1 5875 mm minimum is required E Flooring should be level or below dryer cabinet f...

Страница 8: ...6 in wc 1 48 mb NOTE When the exhaust ductwork passes through a wall ceiling or roof made of combustible materials the opening must be 2 inches 5 08 cm larger than the duct all the way around The duct...

Страница 9: ...uct to the nearest obstruction The length of the ductwork from the dryer to the outside exhaust outlet must not exceed 20 feet 6 09 meters The minimum diameter of this ductwork must be at least 8 inch...

Страница 10: ...ode ANSI NFPA NO 70 LATEST EDITION or in Canada the installation must conform to applicable Canada Standards Canadian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION The ground connection...

Страница 11: ...erials and workmanship conform to local and state regulations or codes of the country of destination In the absence of such codes all plumbing connections materials and workmanship must conform to the...

Страница 12: ...nections The dryer is provided with a 3 4 N P T inlet pipe connection on top of the dryer It is recommended that a gas shutoff valve be provided to the gas supply line of each dryer for ease in servic...

Страница 13: ...s desired setting NOTE When a cycle is interrupted by opening the main door cycle time will continue to count downward regardless if the door is open or closed Selection setting changes can be made at...

Страница 14: ...r cabinet s avoid using harsh abrasives A product intended for the cleaning of appliances is recommended Adjustments 7 Days After Installation and Every 12 Months Thereafter Inspect bolts nuts screws...

Отзывы: