Maytag MLG-45PDB Скачать руководство пользователя страница 13

113489- 3  (W10185535)

Maytag Co.

13

Preoperational Test ___________________

All dryers are thoroughly tested and inspected before leaving
the factory.  However, a preoperational test should be
performed before the dryer is publicly used.  It is possible
that adjustments have changed in transit or due to marginal
location (installation) conditions.
Turn on electric power to the dryer.
Refer to the operating instructions for starting your dryer.
Open all shutoff valves.
When a gas dryer is first started (during initial start-up), it has
a tendency not to ignite on the first ignition attempt.  This is
because the gas supply piping is filled with air, so it may take
a few minutes for the air to be purged from the lines.

NOTE: 

During the purging period, check to be sure that all

gas shutoff valves are open.

Tumbler Coating

The tumbler is treated with a protective coating.  We suggest
dampening old garments or cloth material with a solution of
water and nonflammable mild detergent and tumbling them
in the tumbler to remove this coating.

Microprocessor Programs/Selections

Each microprocessor controller (computer) has been
preprogrammed by the factory with the most commonly used
parameter (program) selections.  If computer program
changes are required, refer to the computer programming
manual, which was shipped with the dryer.

Operating Instructions ________________

The dryer is available for use when the appropriate side of
the microprocessor display reads “0 minutes” and the amount
needed to start the dryer (i.e., “25”).  Once the load has been
put into the dryer and the main door is closed, start the dryer
as follows:
• Insert the proper number of coins into the coin acceptor.

Once the correct “Amount To Start” has been inserted, the
display will read “SELECT CYCLE”.

• Determine fabric setting (selection).

Once the fabric temperature setting (selection) has been

determined, start the dryer by pressing the fabric setting
key.

• The dryer will now start, and the display will read the

setting and the time vended.

• The cycle time will count down until the drying and

cooling cycles are completed.

• Upon completion of the drying and cooling cycles, the

dryer will shut off.

The dryer tumbler can be stopped at any time by opening the
main door.  To restart dryer, shut the main door and press
desired setting.

NOTE:

 When a cycle is interrupted by opening the main

door, cycle time will continue to count downward,
regardless if the door is open or closed.

Selection (setting) changes can be made at any time during
the drying cycle.

Shutdown Instructions ________________

If the dryer is to be shutdown (taken out of service) for a
period of time, the following must be performed:
Discontinue power to the dryer either at the external disconnect
switch or the circuit breaker.
Discontinue the fuel supply: close external gas shutoff valve.
Also close two internal gas shutoff valves.

Service/Parts Information ____________

Service

Service must be performed by a qualified trained technician,
service agency, or gas supplier.  If service is required, contact
the Maytag distributor from whom the equipment was
purchased.  If the distributor cannot be contacted or is
unknown, contact the Maytag Co. for a distributor in your area.

NOTE:

 When contacting the Maytag Co., be sure to give

them the correct model number and serial number so that
your inquiry is handled in an expeditious manner.

Parts

Replacement parts should be purchased from the distributor
from whom the Maytag equipment was purchased.  If the
distributor cannot be contacted or is unknown, contact the
Maytag Co. for a distributor in your area.

NOTE:

 When ordering replacement parts from the Maytag

distributor or the Maytag Co. be sure to give them the
correct model number and serial number so that your parts
order can be processed in an expeditious manner.

Routine Maintenance _________________

A program should be established for the inspection and
cleaning of lint in the burner area, exhaust ductwork, and
area around the back of the dryer.  The frequency of inspection
and cleaning can best be determined from experience at
each location.
Exhaust duct outlet should be checked periodically for
blockages, and if any found, removed.

Cleaning

A program and/or schedule should be established for
periodic inspection, cleaning, and removal of lint from various
areas of the dryer, as well as throughout the ductwork system.
The frequency of cleaning can best be determined from
experience at each location.  Maximum operating efficiency
is dependent upon proper airflow.  The accumulation of lint
can restrict this airflow.

NOTE: 

Suggested time intervals shown are for average

usage, which is considered 6 to 8 operational (running)
hours per day.

Every 6 months, inspect the exhaust ducting and remove any
lint buildup.

Содержание MLG-45PDB

Страница 1: ...MLG 45PDB Installation Manual Stack Dryer Part No 113489 3 W10185535 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE...

Страница 2: ...to light any appliance Do not touch any electrical switch Do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s ph...

Страница 3: ...iminate static unless recommended by the manufacturer of the fabric softener or product Do not use heat to dry articles containing foam rubber or similarly textured rubber like materials Clean lint sc...

Страница 4: ...l entretien des commandes tiquetez tous les fils avant de les d brancher Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux WARNING The dryer must never be operated wit...

Страница 5: ...TAINER 8 16 DRYERS PER 48 53 TRUCK 25 27 VOLTAGE AVAILABLE 120 240V 1 2w 50 60 Hz APPROXIMATE NET WEIGHT 1 015 lb 460 40 kg APPROXIMATE SHIPPING WEIGHT 1 080 lb 489 88 kg AIRFLOW PER POCKET 60 Hz 600...

Страница 6: ...st be installed with adequate clearance for air openings into the combustion chamber IMPORTANT The dryer must be installed in a location environment which the ambient temperature remains between 40 F...

Страница 7: ...from the nearest obstruction 24 inches 60 96 cm is recommended for ease of installation maintenance and service D 1 16 1 5875 mm minimum is required E Flooring should be level or below dryer cabinet f...

Страница 8: ...6 in wc 1 48 mb NOTE When the exhaust ductwork passes through a wall ceiling or roof made of combustible materials the opening must be 2 inches 5 08 cm larger than the duct all the way around The duct...

Страница 9: ...uct to the nearest obstruction The length of the ductwork from the dryer to the outside exhaust outlet must not exceed 20 feet 6 09 meters The minimum diameter of this ductwork must be at least 8 inch...

Страница 10: ...ode ANSI NFPA NO 70 LATEST EDITION or in Canada the installation must conform to applicable Canada Standards Canadian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION The ground connection...

Страница 11: ...erials and workmanship conform to local and state regulations or codes of the country of destination In the absence of such codes all plumbing connections materials and workmanship must conform to the...

Страница 12: ...nections The dryer is provided with a 3 4 N P T inlet pipe connection on top of the dryer It is recommended that a gas shutoff valve be provided to the gas supply line of each dryer for ease in servic...

Страница 13: ...s desired setting NOTE When a cycle is interrupted by opening the main door cycle time will continue to count downward regardless if the door is open or closed Selection setting changes can be made at...

Страница 14: ...r cabinet s avoid using harsh abrasives A product intended for the cleaning of appliances is recommended Adjustments 7 Days After Installation and Every 12 Months Thereafter Inspect bolts nuts screws...

Отзывы: