background image

9

Style 2: Direct wire strain relief

Remove the knockout as needed for the flexible conduit 
connection.

Assemble a UL listed conduit connector in the opening.

Tighten strain relief screw against the flexible conduit. 

5. Complete installation following instructions for your type of 

electrical connection:

4-wire (recommended)

3-wire (if 4-wire is not available)

Electrical Connection Options

4-wire connection: Power Supply Cord

Use this method for:

New branch-circuit installations (1996 NEC)

Mobile homes 

Recreational vehicles

In an area where local codes prohibit grounding through the 
neutral

1. Part of metal ground strap must be cut out and removed.

2. Use a Phillips screwdriver to remove the ground-link screw 

from the back of the range. Save the ground-link screw and 
the end of the ground link under the screw.

3. Feed the power supply cord through the strain relief on the 

cord/conduit plate on bottom of range. Allow enough slack to 
easily attach the wiring to the terminal block.

4. Use a Phillips screwdriver to connect the green ground wire 

from the power supply cord to the range with the ground-link 
screw and ground-link section. The ground wire must be 
attached first.

A. Removable retaining nut
B. Conduit

If your home has:

And you will be 
connecting to:

Go to Section:

4-wire receptacle
(NEMA type 14-50R)

A UL listed, 
250-volt 
minimum, 
40-amp, range 
power supply 
cord

4-wire connection: 
Power supply cord

4-wire direct

A circuit breaker 
box or fused 
disconnect

4-wire connection: 
Direct wire

3-wire receptacle
(NEMA type 10-50R)

A UL listed, 
250-volt 
minimum, 
40-amp, range 
power supply 
cord

3-wire connection: 
Power supply cord

3-wire direct

A circuit breaker 
box or fused 
disconnect

3-wire connection:
Direct wire

A

B

(12.7 cm)

5"

³⁄₈

"

(1.0 cm)

3"

(7.6 cm)

³⁄₈

"

(1.0 cm)

A. Metal ground strap
B. Discard

C. Ground-link screw

A. Terminal block
B. Ground-link screw

C. UL listed strain relief
D. Power supply cord wires

A

B
C

A

B

D

C

Содержание MIR8890AS

Страница 1: ...equirements U S A Only 5 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Install Anti Tip Bracket 6 Electrical Connection U S A Only 8 Verify Anti Tip Bracket Is Installed and Engaged 12 Level Range 13 Warming Drawer or Premium Storage Drawer 13 Storage Drawer 14 Oven Door 14 Complete Installation 15 Moving the Range 15 IMPORTANT Save for local electrical inspector s use W10403811B ...

Страница 2: ... the safety alert symbol and either the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING Tip Over Hazard A child or adult can tip the range and be killed Install anti tip bracket to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of the anti tip bracket Re engage anti tip bracket if range is moved Do not ...

Страница 3: ...projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The anti tip bracket must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See the appropriate Electrical Requirements section IMPO...

Страница 4: ...om of wood or metal cabinet is covered by not less than 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet A 27 70 5 cm max depth with handle B 46 119 1 cm overall height m...

Страница 5: ...ible or nonmetallic sheathed copper or aluminum cable See the Electrical Connection U S A Only section Allow 2 to 3 ft 61 0 cm to 91 4 cm of slack in the line so that the range can be moved if servicing is ever necessary A UL listed conduit connector must be provided at each end of the power supply cable at the range and at the junction box Wire sizes and connections must conform with the rating o...

Страница 6: ...i tip bracket from where it is taped inside the storage drawer or warming drawer 2 Determine which mounting method to use floor or wall If you have a stone or masonry floor you can use the wall mounting method If you are installing the range in a mobile home you must secure the range to the floor A Shipping base A drive ratchet B Rear leveling leg C Wrench or pliers D Front leveling leg WARNING Ex...

Страница 7: ...nting Wall Mounting 5 Using the Phillips screwdriver mount anti tip bracket to the wall or floor with the two 12 x 1 screws provided 6 Move range close enough to opening to allow for final electrical connections Remove shipping base cardboard or hardboard from under range 7 Move range into its final location making sure rear leveling leg slides into anti tip bracket 8 Move range forward onto shipp...

Страница 8: ...pening Tighten strain relief screw against the power supply cord Power Supply Cord Direct Wire WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instructions can result in death fire or electrical shock WARNING Electrical Shock Hazard Disconnect power before servicing Use 8 gauge copper or 6 gaug...

Страница 9: ...e strain relief on the cord conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block 4 Use a Phillips screwdriver to connect the green ground wire from the power supply cord to the range with the ground link screw and ground link section The ground wire must be attached first A Removable retaining nut B Conduit If your home has And you will be connectin...

Страница 10: ...to the outer terminal block posts with 10 32 hex nuts 4 Securely tighten hex nuts NOTE For power supply cord replacement use only a power cord rated at 250 volts minimum 40 amps or 50 amps that is marked for use with nominal 1 3 5 cm diameter connection opening with ring terminals and marked for use with ranges 5 Tighten strain relief screws 6 Replace terminal block access cover Direct Wire Instal...

Страница 11: ...ing terminal lugs to the terminal block 20 lbs in 2 3 N m 5 Use a hex or Phillips screwdriver to connect the bare green ground wire to the range with the ground link screw and ground link section The ground wire must be attached first and must not contact any other terminal 6 Use nut driver to connect the neutral white wire to the center terminal block post with one of the 10 32 hex nuts 7 Connect...

Страница 12: ...talledand Engaged On Ranges with a Storage Drawer 1 Remove the storage drawer See Storage Drawer section 2 Use a flashlight to look underneath the bottom of the range 3 Visually check that the rear range foot is inserted into the slot of the anti tip bracket On Ranges with a Warming Drawer or Premium Storage Drawer 1 Place the outside of your foot against the bottom front of the warming drawer or ...

Страница 13: ... in one of the two figures below depending on the size of the level Check with the level side to side and front to back 2 If range is not level pull range forward until rear leveling leg is removed from the anti tip bracket 3 Follow the directions in Style 1 or Style 2 depending on the style of drawer supplied with the range For Ranges without AquaLift Technology or Steam Clean 1 Place a standard ...

Страница 14: ...r into the range NOTE When properly installed the rear slides on the bottom of the drawer will engage the base rails and the drawer will not tip when items are placed in the drawer OvenDoor For normal range use it is not suggested to remove the oven door However if removal is necessary make sure the oven is off and cool Then follow these instructions The oven door is heavy To Remove 1 Open oven do...

Страница 15: ...he range has been on for 5 minutes check for heat If range is cold turn off the range and contact a qualified technician MovingtheRange When moving range slide range onto cardboard or hardboard to avoid damaging the floor covering If removing the range is necessary for cleaning or maintenance For power supply cord connected ranges 1 Slide range forward 2 Unplug the power supply cord 3 Complete cle...

Страница 16: ...W10403811B 2011 All rights reserved TM AQUALIFT is a trademark of Whirlpool U S A 12 11 Printed in U S A ...

Отзывы: