background image

5

Electrical Requirements - U.S.A. Only

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.

Do not use an extension cord.

Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances. 

A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

WARNING: Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. Check with a 
qualified electrician or service technician if you are in doubt as to 
whether the appliance is properly grounded. Do not modify the 
power supply cord plug. If it will not fit the outlet, have a proper 
outlet installed by a qualified electrician.

Electrical Connection

To properly install your range, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.

Range must be connected to the proper electrical voltage 
and frequency as specified on the model/serial rating plate. 
The model/serial rating plate is located on the left side frame 
behind the storage drawer panel or behind the top right side 
of the oven door. Refer to the figures in “Product Dimensions” 
in the “Location Requirements” section.

This range is manufactured with the neutral terminal 
connected to the cabinet. Use a 3-wire, UL listed, 40- or 50-
amp power supply cord (pigtail) (see the following Range 
Rating chart). If local codes do not permit ground through the 
neutral, use a 4-wire power supply cord rated at 250 volts, 
40 or 50 amps and investigated for use with ranges.

*The NEC calculated load is less than the total connected load 

listed on the model/serial rating plate.

**If connecting to a 50-amp circuit, use a 50-amp rated cord with 

kit. For 50-amp rated cord kits, use kits that specify use with a 
nominal 1

³⁄₈

" (34.9 mm) diameter connection opening.

A circuit breaker is recommended.

The range can be connected directly to the circuit breaker 
box (or fused disconnect) through flexible or nonmetallic 
sheathed, copper or aluminum cable. See the “Electrical 
Connection - U.S.A. Only” section.

Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that 
the range can be moved if servicing is ever necessary.

A UL listed conduit connector must be provided at each end 
of the power supply cable (at the range and at the junction 
box).

Wire sizes and connections must conform with the rating of 
the range.

The wiring diagram is located on the Tech Sheet.

The Tech Sheet is located on the back of the range inside a 
clear plastic bag.

If connecting to a 4-wire system:

This range is manufactured with the ground connected to the 
neutral by a link. The ground must be revised so the green 
ground wire of the 4-wire power supply cord is connected to the 
cabinet. See “Electrical Connection - U.S.A. Only” section.

Grounding through the neutral conductor is prohibited for new 
branch-circuit installations (1996 NEC); mobile homes; and 
recreational vehicles, or an area where local codes prohibit 
grounding through the neutral conductor.

When a 4-wire receptacle of NEMA Type 14-50R is used, a 
matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power 
supply cord (pigtail) must be used. This cord contains 4 copper 
conductors with ring terminals or open-end spade terminals with 
upturned ends, terminating in a NEMA Type 14-50P plug on the 
supply end. 

The fourth (grounding) conductor must be identified by a green or 
green/yellow cover and the neutral conductor by a white cover. 
Cord should be Type SRD or SRDT with a UL listed strain relief 
and be at least 4 ft (1.22 m) long.

The minimum conductor sized for the copper 4-wire power 
cord are:

40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding

If connecting to a 3-wire system:

Local codes may permit the use of a UL listed, 3-wire, 250-volt, 
40- or 50-amp range power supply cord (pigtail). This cord 
contains 3 copper conductors with ring terminals or open-end 
spade terminals with upturned ends, terminating in a NEMA Type 
10-50P plug on the supply end. Connectors on the appliance end 
must be provided at the point the power supply cord enters the 
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.

Range Rating*

Specified Rating of 
Power Supply Cord Kit 
and Circuit Protection

120/240 Volts

120/208 Volts

Amps

8.8 - 16.5 KW
16.6 - 22.5 KW

7.8 - 12.5 KW
12.6 - 18.5 KW

40 or 50**
50

4-wire receptacle (14-50R)

3-wire receptacle (10-50R)

Содержание MIR8890AS

Страница 1: ...equirements U S A Only 5 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Install Anti Tip Bracket 6 Electrical Connection U S A Only 8 Verify Anti Tip Bracket Is Installed and Engaged 12 Level Range 13 Warming Drawer or Premium Storage Drawer 13 Storage Drawer 14 Oven Door 14 Complete Installation 15 Moving the Range 15 IMPORTANT Save for local electrical inspector s use W10403811B ...

Страница 2: ... the safety alert symbol and either the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING Tip Over Hazard A child or adult can tip the range and be killed Install anti tip bracket to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of the anti tip bracket Re engage anti tip bracket if range is moved Do not ...

Страница 3: ...projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The anti tip bracket must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See the appropriate Electrical Requirements section IMPO...

Страница 4: ...om of wood or metal cabinet is covered by not less than 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet A 27 70 5 cm max depth with handle B 46 119 1 cm overall height m...

Страница 5: ...ible or nonmetallic sheathed copper or aluminum cable See the Electrical Connection U S A Only section Allow 2 to 3 ft 61 0 cm to 91 4 cm of slack in the line so that the range can be moved if servicing is ever necessary A UL listed conduit connector must be provided at each end of the power supply cable at the range and at the junction box Wire sizes and connections must conform with the rating o...

Страница 6: ...i tip bracket from where it is taped inside the storage drawer or warming drawer 2 Determine which mounting method to use floor or wall If you have a stone or masonry floor you can use the wall mounting method If you are installing the range in a mobile home you must secure the range to the floor A Shipping base A drive ratchet B Rear leveling leg C Wrench or pliers D Front leveling leg WARNING Ex...

Страница 7: ...nting Wall Mounting 5 Using the Phillips screwdriver mount anti tip bracket to the wall or floor with the two 12 x 1 screws provided 6 Move range close enough to opening to allow for final electrical connections Remove shipping base cardboard or hardboard from under range 7 Move range into its final location making sure rear leveling leg slides into anti tip bracket 8 Move range forward onto shipp...

Страница 8: ...pening Tighten strain relief screw against the power supply cord Power Supply Cord Direct Wire WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instructions can result in death fire or electrical shock WARNING Electrical Shock Hazard Disconnect power before servicing Use 8 gauge copper or 6 gaug...

Страница 9: ...e strain relief on the cord conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block 4 Use a Phillips screwdriver to connect the green ground wire from the power supply cord to the range with the ground link screw and ground link section The ground wire must be attached first A Removable retaining nut B Conduit If your home has And you will be connectin...

Страница 10: ...to the outer terminal block posts with 10 32 hex nuts 4 Securely tighten hex nuts NOTE For power supply cord replacement use only a power cord rated at 250 volts minimum 40 amps or 50 amps that is marked for use with nominal 1 3 5 cm diameter connection opening with ring terminals and marked for use with ranges 5 Tighten strain relief screws 6 Replace terminal block access cover Direct Wire Instal...

Страница 11: ...ing terminal lugs to the terminal block 20 lbs in 2 3 N m 5 Use a hex or Phillips screwdriver to connect the bare green ground wire to the range with the ground link screw and ground link section The ground wire must be attached first and must not contact any other terminal 6 Use nut driver to connect the neutral white wire to the center terminal block post with one of the 10 32 hex nuts 7 Connect...

Страница 12: ...talledand Engaged On Ranges with a Storage Drawer 1 Remove the storage drawer See Storage Drawer section 2 Use a flashlight to look underneath the bottom of the range 3 Visually check that the rear range foot is inserted into the slot of the anti tip bracket On Ranges with a Warming Drawer or Premium Storage Drawer 1 Place the outside of your foot against the bottom front of the warming drawer or ...

Страница 13: ... in one of the two figures below depending on the size of the level Check with the level side to side and front to back 2 If range is not level pull range forward until rear leveling leg is removed from the anti tip bracket 3 Follow the directions in Style 1 or Style 2 depending on the style of drawer supplied with the range For Ranges without AquaLift Technology or Steam Clean 1 Place a standard ...

Страница 14: ...r into the range NOTE When properly installed the rear slides on the bottom of the drawer will engage the base rails and the drawer will not tip when items are placed in the drawer OvenDoor For normal range use it is not suggested to remove the oven door However if removal is necessary make sure the oven is off and cool Then follow these instructions The oven door is heavy To Remove 1 Open oven do...

Страница 15: ...he range has been on for 5 minutes check for heat If range is cold turn off the range and contact a qualified technician MovingtheRange When moving range slide range onto cardboard or hardboard to avoid damaging the floor covering If removing the range is necessary for cleaning or maintenance For power supply cord connected ranges 1 Slide range forward 2 Unplug the power supply cord 3 Complete cle...

Страница 16: ...W10403811B 2011 All rights reserved TM AQUALIFT is a trademark of Whirlpool U S A 12 11 Printed in U S A ...