Страница 1: ...oof materials in accordance with the Federal Standard for Mobile Home Construction and Safety To eliminate the risk of burns or fire by reaching over heated surface units cabinet storage space located...

Страница 2: ...all Maximum depth of cabinets installed above cooktop to be 13 inches 6 inches minimum spacing between individual top sections in a dual installation 30 AND 36 SEALED BURNER WITH PORCELAIN TOP DIM C 2...

Страница 3: ...MIN IB a MIN jl _ _ PROVIDE FOR I_O VAC ELECTRIC OUTLET GROUNDED IN _ CENTER OF CABINET BELOW COOKTDP OF CABINET 36 SEALED BURNER WITH GLASS TOP COMBUSTIBLE WALL 25 NORMAL CABINET TOP DEPTH COMBUSTIB...

Страница 4: ...T AND SHUTOFF VALVE MUST BE INSTALLED IN AN ACCESSIBLE LOCATION REGULATOR INLET IS FEMALE 1 2 NPT 28 5 16 MINIMUM TO ANY COMBUSTIBLE WALL ABOVE COOKTOP 3 7 8 MIN 36 SEALED BURNER WITH PORCELAIN TOP 1...

Страница 5: ...ELECTRICAL CONNECTIONS 30 SEALED BURNER WITH GLASS TOP 21 30 NOTE WHEN INSTALLED OVER A 30 WALL OVEN ATTACH 90 ELBOW TO SURFACE UNIT PIPING AND LOCATE REGULATOR SHUTOFF VALVE IN ADJACENT ACCESSIBLE C...

Страница 6: ...4 X 1 4 GASKET GASKET ENTIRE PERIMETER APPLY 1 4 X 1 4 FOAM GASKET _ TO FLAT S U RFAOEOFGLASS G ASKET E NTIREPER IMETER DETAIL A SEE DETAILA 2 Position cooktop in cutout 3 From inside cabinet positio...

Страница 7: ...side wall Maximum depth of cabinets installed above cooktop to be 13 inches 6 inches minimum spacing between individual top sections in a dual installation 30 CONVENTIONAL BURNER WITH PORCELAIN TOP CO...

Страница 8: ...WITH UNIT ANO SHUTOFF VALVE MUST BE INSTALLED IN AN ACCESSIBLE LOCATION SUPPLIED WITH 1 2 NPT FEMALE INLET ON REGULATOR 28 5 1 6 MINIMUM TO ANY COMBUSTIBLE WALL ABOVE COOKTOP 19 13 1B ATTACH BURNER BO...

Страница 9: ...RV Series Clearance Dimensions For complete information in regard to the installation and clearances to combustible wall above the cooking top see the installation drawings For SAFETY CONSIDERATIONS...

Страница 10: ...vings rust dirt and liquids oil or water Dirt etc in the supply lines can work its way into the range manifold and in turn cause failure of the gas valves or controls and clog burners and or pilot ori...

Страница 11: ...its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 Ibs sq in 13 8 in W C 2 The appliance...

Страница 12: ...For ranges with hi med warm valves turn knob either direction to HI setting Top Burner Adjustment HI LOW VALVES The approximate height of the flame at the high or full on position is a distinct inner...

Страница 13: ...Conversion The appliance pressure regulator must be set to match the type gas supply used If converting from natural gas to LP gas the appliance pressure regulator must be converted to regulate LP gas...

Страница 14: ...GAS TO NATURAL GAS a Change the appliance pressure regulator from LP to natural setting See figure 10 11 or 12 b Screw the burner orifice hoods away from the pins See figure 13A Approximately 1 1 2 t...