Maytag MED5900TW0 Скачать руководство пользователя страница 5

TECH SHEET - DO NOT DISCARD

PAGE 5

FOR SERVICE TECHNICIAN’S USE ONLY

PART NO. W10112987A

4.

Measure resistance between the motor
relay common (COM) terminal and
ground. A high resistance (open) should
be measured.

If it does not, perform the Thermal
Fuse Test and Door Switch Test and
check harness continuity. If they test
good, replace the motor.

Door Switch Test

1.

Unplug dryer or disconnect power.

2.

Check door switch continuity. Neutral to
P2-6 on the electronic control should
read closed with the door closed, and
open with the door open.

3.

Otherwise, verify harness continuity.

If no continuity, repair or replace the
harness.

If harness is good, replace the door
switch.

Temperature Switch Test

1.

Unplug dryer or disconnect power.

2.

Remove the wires from the switch to
complete this test.

3.

Reference contact continuity with
Pins 1 and 2 to Pin 4 (White).

4.

Reference contact continuity with Pin 3
to Pin 5.

Temperature Switch Table

SWITCH

POSITION

CONTACTS

FUNCTION

3–5 2–4 1–4

12 o’clock

O

O

O

Air Fluff, No Heat

2 o’clock

O

O

X

Ex-Low

4 o’clock

O

X

O

Low

5 o’clock

O

X

X

Medium, Casual

7 o’clock

X

O

O

High

8 o’clock

X

O

X

Normal

10 o’clock

X

X

O

Medium, Energy

Saver

O = OPEN       X = CLOSED

Wrinkle Prevent Switch (On/Off)
Test

1.

Unplug dryer or disconnect power.

2.

Remove the wires from the switch to
complete this test.

3.

Reference contact continuity with Pin 1
to Pin 4 (White).

Wrinkle Prevent Switch Table

SWITCH

POSITION

CONTACTS

FUNCTION

11 o’clock

Open

Wrinkle Prevent

Off

1 o’clock

Closed

Wrinkle Prevent

On

End of Cycle Signal Switch Test

1.

Unplug dryer or disconnect power.

2.

Remove the wires from the switch to
complete this test.

3.

Reference contact continuity with Pins 1
and 2 to Pin 4 (White).

End of Cycle Signal Switch Table

SWITCH

POSITION

CONTACTS

FUNCTION

1–4

2–4

10 o’clock

O

O

Off

12 o’clock

X

O

Softer End of

Cycle Signal

2 o’clock

O

X

Louder End of

Cycle Signal

O = OPEN    X = CLOSED

High Limit Thermostat Test

1.

Unplug dryer or disconnect power.

2.

Remove the high limit thermostat and
check continuity. Refer to the Thermal
Components illustration above right.

If open, replace the high limit
thermostat.

If closed, apply heat. It should open at
about 250°F (121°C). Otherwise,
replace the high limit thermostat.

Thermal Cut-Off Test

This unit is equipped with a “one-shot”
thermal cut-off. See Thermal Components
illustration above. If the dryer does not heat
with power supplied:

1.

Unplug dryer or disconnect power.

2.

Check the thermal cut-off for continuity.

If open, thermal cut-off has failed and
must be replaced.

NOTE

: If the thermal cut-off has failed,

replace the thermal cut-off and high limit
thermostat. In addition, check for failed
heater element, or blocked or improper
exhaust system.

Thermal Fuse Test

A thermal fuse is used on this model. The
thermal fuse is wired in series with the
dryer drive motor. If the thermal fuse
opens, power is shut off to the motor.

1.

Unplug dryer or disconnect power.

2.

Check continuity of thermal fuse.

3.

Once the thermal fuse has opened, it
must be replaced. Check for failed
thermistor, shorted heat element, or
other causes of failure. Replace failed
parts. See Thermal Components
illustration above.

1

2

3

Orange

FABRIC

Violet

Tan

4

5

White

1

2

SIGNAL

4

White

Tan-White

White-Black

Thermal

Fuse

Thermistor

Thermal

Cut-Off

High Limit

Thermostat

Heat

Element

Thermal Components.

1

WRINKLE

GUARD

4

White

Gray

Содержание MED5900TW0

Страница 1: ...en or loose wires Check for wires not pressed into connector far enough to engage metal barbs Resistance checks must be made with dryer unplugged or power disconnected LESS DRY TEST Begin with a fully...

Страница 2: ...DRIVE MOTOR 1 3 H P 5M 6M THERMISTOR 10 k BK DL 5400 WATT 2700 WATT EACH LEG ELECTRONIC CONTROL NEUTRAL TERMINAL LINKED TO CABINET CENTRIFUGAL SWITCH THERMAL FUSE 196 F 91 C HIGH LIMIT THERMOSTAT 180...

Страница 3: ...BU MOTOR STRIP CIRCUIT 120 VOLTS 240 VOLTS 2M 1M 5M 6M THERMISTOR 10 k ELECTRONIC CONTROL THERMAL CUT OFF TCO 310 F 154 C NEUTRAL TERMINAL LINKED TO CABINET CENTRIFUGAL SWITCH HIGH LIMIT THERMOSTAT 18...

Страница 4: ...ntinuity between the L1 terminal of the plug found in step 4 and BK black wire terminal on the timer If there is continuity go to step 7 If there is no continuity check that wires to the terminal bloc...

Страница 5: ...2 Remove the wires from the switch to complete this test 3 Reference contact continuity with Pins 1 and 2 to Pin 4 White End of Cycle Signal Switch Table SWITCH POSITION CONTACTS FUNCTION 1 4 2 4 10 o...

Страница 6: ...RE CLOTHES ARE DRY Refer to Thermistor Test this page and Moisture Sensor Strip Circuit page 3 HARNESS CONNECTION MOISTURE SENSOR THERMISTOR ELECTRONIC CONTROL MAY NEED TO CHANGE TIMER SETTING TO A MO...

Страница 7: ...shooting Guide page 6 1 Perform Temperature Switch Test page 5 2 Unplug dryer or disconnect power 3 Check continuity of heater relay contacts COM to NO should be open If not replace the heater relay 4...

Страница 8: ...Test page 6 3 If problem persists after replacing moisture sensor and thermistor Unplug dryer or disconnect power Replace the electronic control assembly PROBLEM Timer Continuously Advances Refer to T...

Отзывы: