Maytag MED5900TW0 Скачать руководство пользователя страница 2

PAGE 2

TECH SHEET - DO NOT DISCARD

PART NO. W10112987A

FOR SERVICE TECHNICIAN’S USE ONLY

Red

Blue

White Green-

Yellow

Red

Black

Violet

Main Winding

Start Winding

Pluggable Drive Motor Switch

1

1

1

4

1

5

5

4

PS

0

2

PS

0

3

PS

0

1

PS0

4

7

8

PT

-1

Electronic Control Assembly

W

R

B
U

PT-1

V

B
K

DA

T

E

Timer

Red-White

Red-White

Red-

White

Red-

White

D.C. Heater Relay

1M 2M 3M 5M 6M

=

Contacts closed

Contacts

Function

Start

Run

Centrifugal Switch (Motor)

Drum Size:

7 cubic feet

Drum Speed:

48 ± 3 RPM CW

Blue

Blue

Pink-

Black

Pink-

Black

Motor Relay

Timer

BU

BK

R

V

W

Wire Colors

Blue

Black

Red

Violet White

Brown

Brown

Brown

Brown

A.C. Heater Relay

120 VOLTS

240 VOLTS

L1 LINE – BK

– LINE L2

R

W – NEUTRAL

2M

1M

DOOR
SWITCH

DRIVE MOTOR

1/3 H.P.

5M

6M

THERMISTOR

10 k

BK

DL

5400 WATT
2700 WATT

EACH LEG

ELECTRONIC CONTROL

NEUTRAL
TERMINAL
LINKED TO
CABINET

CENTRIFUGAL SWITCH

THERMAL FUSE

196 °F (91°C)

HIGH LIMIT

THERMOSTAT

180°F (82°C)

TIMER

PT-1

DOOR

DRUM LAMP

MTR

P1-1

TIMER

T2

P1-2

MOIST.

T3

P1-3

TEMP.

T4

P1-4

NEUTRAL

P2-5

P2-6

SENSOR

P2-4

P2-3

P2-1

WRINKLE

PREVENT

FABRIC

P3-6

P3-5

FS-1

FS-2

FS-3

WPREVENT

SIGNAL

P3-4

P3-3

SOFT

HEATER

RELAY

P3-2

HEATER
HI

3M

1

4

3

2

1

4

5

P3-8

2

1

4

P3-1

HEATER
LOW

P3-7

W

BU

BK

R-W

BK

BU

V

R

W

BU

R-W

COM

NO

OR

BU

Y-R

W

R

W-R

BU

G-Y

G-Y

W

R-W

R-W

GY

W

T

V

OR

T-W

W-BK

TCO

310°F

(154°C)

MODEL

LOUD

BU

MOIST

GND

P2-7

BU

PK-BK

PTS

MOTOR

RELAY

PK-BK

BU

BK

BU

BK

COM

NO

MOTOR
START

START
SENSE

BU-BK

P1-5

R-W

AC COIL

HEATER RELAY

P4-4

L1-RTN

P4-3

120 VAC RLY DR.

P4-2

MODEL

P4-1

MODEL

BR

BR

NC

BK

R

R

BU

W

R

R

W

BR

BR

MAIN

2.4–3.6
START

2.4–3.8

48
VDC

48 VDC

Electric Dryer Wiring Diagram

Содержание MED5900TW0

Страница 1: ...en or loose wires Check for wires not pressed into connector far enough to engage metal barbs Resistance checks must be made with dryer unplugged or power disconnected LESS DRY TEST Begin with a fully...

Страница 2: ...DRIVE MOTOR 1 3 H P 5M 6M THERMISTOR 10 k BK DL 5400 WATT 2700 WATT EACH LEG ELECTRONIC CONTROL NEUTRAL TERMINAL LINKED TO CABINET CENTRIFUGAL SWITCH THERMAL FUSE 196 F 91 C HIGH LIMIT THERMOSTAT 180...

Страница 3: ...BU MOTOR STRIP CIRCUIT 120 VOLTS 240 VOLTS 2M 1M 5M 6M THERMISTOR 10 k ELECTRONIC CONTROL THERMAL CUT OFF TCO 310 F 154 C NEUTRAL TERMINAL LINKED TO CABINET CENTRIFUGAL SWITCH HIGH LIMIT THERMOSTAT 18...

Страница 4: ...ntinuity between the L1 terminal of the plug found in step 4 and BK black wire terminal on the timer If there is continuity go to step 7 If there is no continuity check that wires to the terminal bloc...

Страница 5: ...2 Remove the wires from the switch to complete this test 3 Reference contact continuity with Pins 1 and 2 to Pin 4 White End of Cycle Signal Switch Table SWITCH POSITION CONTACTS FUNCTION 1 4 2 4 10 o...

Страница 6: ...RE CLOTHES ARE DRY Refer to Thermistor Test this page and Moisture Sensor Strip Circuit page 3 HARNESS CONNECTION MOISTURE SENSOR THERMISTOR ELECTRONIC CONTROL MAY NEED TO CHANGE TIMER SETTING TO A MO...

Страница 7: ...shooting Guide page 6 1 Perform Temperature Switch Test page 5 2 Unplug dryer or disconnect power 3 Check continuity of heater relay contacts COM to NO should be open If not replace the heater relay 4...

Страница 8: ...Test page 6 3 If problem persists after replacing moisture sensor and thermistor Unplug dryer or disconnect power Replace the electronic control assembly PROBLEM Timer Continuously Advances Refer to T...

Отзывы: