Maytag MED5900TW0 Скачать руководство пользователя страница 1

TECH SHEET - DO NOT DISCARD

PAGE 1

FOR SERVICE TECHNICIAN’S USE ONLY

PART NO. W10112987A

WARNING

Electrical Shock Hazard

Disconnect power before
servicing.

Replace all parts and
panels before operating.

Failure to do so can result
in death or
electrical shock.

IMPORTANT

Electrostatic Discharge (ESD)

Sensitive Electronics

Do not open package until it is time to
install the electronic board.

ESD problems are present everywhere.
ESD may damage or weaken the
electronic board. The new board may
appear to work well after repair is
finished, but failure may occur at a later
date due to ESD stress.

Use an anti-static wrist strap. Connect
wrist strap to green ground connection
point or unpainted metal in the
appliance

-OR-

Touch your finger repeatedly to a green
ground connection point or unpainted
metal in the appliance.

Before removing the part from its
package, touch the anti-static bag to a
green ground connection point or
unpainted metal in the appliance.

Avoid touching electronic parts or
terminal contacts; handle electronic
board by edges only.

When repackaging failed electronic
board in anti-static bag, observe above
instructions.

DIAGNOSTIC GUIDE

Before servicing, check the following:

Make sure there is power at the wall
outlet.

Has a household fuse blown or circuit
breaker tripped? Time delay fuse?

Is dryer vent properly installed and
clear of lint or obstructions?

All tests/checks should be made with
a VOM (volt-ohm-milliammeter) or
DVM (digital-voltmeter) having a
sensitivity of 20,000

per volt DC or

greater.

Check all connections before
replacing components. Look for
broken or loose wires, failed terminals,
or wires not pressed into connectors
far enough.

A potential cause of a control not
functioning is corrosion on
connections. Observe connections
and check for continuity with an
ohmmeter.

Connectors: Look at top of connector.
Check for broken or loose wires.
Check for wires not pressed into
connector far enough to engage metal
barbs.

Resistance checks must be made with
dryer unplugged or power
disconnected.

LESS DRY TEST

Begin with a fully assembled, empty dryer
with clean lint screen. Be sure dryer is
connected to a known good power source.

1.

Set the following configuration:

Door - must be closed

Timer - Less Dry

Temperature switch - High

End of Cycle Signal switch - Louder

2.

Press the Push to Start (PTS) switch.
After approximately 16 seconds, the
Timer will start to advance to the Off
position. If this function does not occur,
proceed to the Diagnostic Test.

DIAGNOSTIC TEST

This diagnostic test allows factory/service
personnel to test and verify all inputs to the
electronic control. The basic operation of this
test is to notify the operator with an audible
beep every time the status of an input to the
control changes state.

This test is performed with a fully assembled
dryer, connected to a known good power
source.

Activating the Test Mode

1.

Set the following configuration:

Door - must be open

Temperature switch - Air Fluff

End of Cycle Signal switch - Louder

Timer - Timed Drying or Sensor Drying
selection

2.

Turn the Wrinkle Prevent switch from Off
to On three times within a five second
period. A single beep, a pause, then a
single beep will sound to indicate that the
test mode is activated.

NOTE:

If any of these initial conditions are

not satisfied, the control will not enter the
test mode.

Test Mode Functionality

When the control is in test mode, every input
change of state will result in an audible beep
(with the exception of the End of Cycle Signal
switch). This includes:

Door switch

Moisture Sensor (short/open Sensor
will result in a beep)

NOTE:

A moistened finger or damp

cloth may also be used.

Temperature switch

Wrinkle Prevent switch

Push to Start (PTS) switch (with the
door switch closed)

Timer (any cam input change will result
in a beep)

NOTE:

Timer will advance during test.

If any of the inputs do not result in a beep,
proceed to the corresponding component
tests, beginning on page 4.

Содержание MED5900TW0

Страница 1: ...en or loose wires Check for wires not pressed into connector far enough to engage metal barbs Resistance checks must be made with dryer unplugged or power disconnected LESS DRY TEST Begin with a fully...

Страница 2: ...DRIVE MOTOR 1 3 H P 5M 6M THERMISTOR 10 k BK DL 5400 WATT 2700 WATT EACH LEG ELECTRONIC CONTROL NEUTRAL TERMINAL LINKED TO CABINET CENTRIFUGAL SWITCH THERMAL FUSE 196 F 91 C HIGH LIMIT THERMOSTAT 180...

Страница 3: ...BU MOTOR STRIP CIRCUIT 120 VOLTS 240 VOLTS 2M 1M 5M 6M THERMISTOR 10 k ELECTRONIC CONTROL THERMAL CUT OFF TCO 310 F 154 C NEUTRAL TERMINAL LINKED TO CABINET CENTRIFUGAL SWITCH HIGH LIMIT THERMOSTAT 18...

Страница 4: ...ntinuity between the L1 terminal of the plug found in step 4 and BK black wire terminal on the timer If there is continuity go to step 7 If there is no continuity check that wires to the terminal bloc...

Страница 5: ...2 Remove the wires from the switch to complete this test 3 Reference contact continuity with Pins 1 and 2 to Pin 4 White End of Cycle Signal Switch Table SWITCH POSITION CONTACTS FUNCTION 1 4 2 4 10 o...

Страница 6: ...RE CLOTHES ARE DRY Refer to Thermistor Test this page and Moisture Sensor Strip Circuit page 3 HARNESS CONNECTION MOISTURE SENSOR THERMISTOR ELECTRONIC CONTROL MAY NEED TO CHANGE TIMER SETTING TO A MO...

Страница 7: ...shooting Guide page 6 1 Perform Temperature Switch Test page 5 2 Unplug dryer or disconnect power 3 Check continuity of heater relay contacts COM to NO should be open If not replace the heater relay 4...

Страница 8: ...Test page 6 3 If problem persists after replacing moisture sensor and thermistor Unplug dryer or disconnect power Replace the electronic control assembly PROBLEM Timer Continuously Advances Refer to T...

Отзывы: