background image

9

®

TEFLON is a registered trademark of Chemours.

Option 2 (Alternate Method)

Approved aluminum or copper tubing: 

 

Must include 1/8" NPT minimum plugged tapping accessible 

for test gauge connection, immediately upstream of the gas 

connection to the dryer. See illustration below.

 

1/2" IPS pipe is recommended.

 

 3/8" approved aluminum or copper tubing is acceptable for 

lengths under 20 ft. (6.1 m) if local codes and gas supplier 

permit. 

 

If you are using natural gas, do not use copper tubing.

 

Lengths over 20 ft. (6.1 m) should use larger tubing and  

a different size adapter fitting.

 

If your dryer has been converted to use propane gas, 3/8"  

propane compatible copper tubing can be used. If the total 

length of the supply line is more than 20 ft. (6.1 m), use  

larger pipe.

NOTE:

 Pipe-joint compounds that resist the action  

of propane gas must be used. Do not use TEFLON

®† 

tape.

 

Must include shut-off valve.

In the U.S.A.:

An individual manual shut-off valve must be installed within  

six (6) ft. (1.8 m) of the dryer in accordance with the National 

Fuel Gas Code, ANSI Z223.1. The location should be easy  

to reach for opening and closing. 

In Canada:

An individual manual shut-off valve must be installed in  

accordance with the B149.1, Natural Gas and Propane  

Installation Code. It is recommended that an individual  

manual shut-off valve be installed within six (6) ft. (1.8 m)  

of the dryer. The location should be easy to reach for 

opening and closing.

A.  3/8" flexible gas connector

B.  3/8" pipe to flare adapter fitting 

C. 1/8" NPT minimum plugged tapping

D. 1/2" NPT gas supply line

E.  Gas shut-off valve

A

B

E

D

C

GAS SUPPLY REQUIREMENTS

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make 

sure gas pressure does not exceed 13" (330 mm) water 

column. 
Examples of a qualified person include: 
licensed heating personnel, 

authorized gas company personnel, and

authorized service personnel.
Failure to do so can result in death, explosion, or fire.

GAS TYPE

Natural Gas:

This dryer is equipped for use with natural gas. It is certified  

by UL for use with propane gas with appropriate conversion.

 

Your dryer must have the correct burner for the type of gas  

in your home. Burner information is located on the rating plate 

in the door well of your dryer. If this information does not agree 

with the type of gas available, contact your dealer or call the 

phone numbers referenced in the “Assistance or Service” 

section of your Use and Care Guide.

Propane Gas Conversion:

IMPORTANT:

 Conversion must be made by a qualified 

technician.

No attempt shall be made to convert the appliance from the gas 

specified on the model/serial rating plate for use with a different 

gas without consulting your gas company.

GAS SUPPLY LINE
Option 1 (Recommended Method)

Flexible stainless steel gas connector:

 

If local codes permit, use a new flexible stainless steel gas 

connector (Design Certified by the American Gas Association 

or CSA International) to connect your dryer to the rigid gas 

supply line. Use an elbow and a 3/8" flare x 3/8" NPT adapter 

fitting between the stainless steel gas connector and the  

dryer gas pipe, as needed, to prevent kinking.

Содержание MED5630HW

Страница 1: ...A ONLY 7 ELECTRIC DRYER POWER HOOKUP CANADA ONLY 8 GAS DRYER POWER HOOKUP 8 INSTALL LEVELING LEGS 10 MAKE ELECTRICAL CONNECTION U S A ONLY 11 Power Supply Cord Connection 12 Direct Wire Connection 14...

Страница 2: ...2 DRYER SAFETY...

Страница 3: ...r Clear the room building or area of all occupants IMPORTANT The gas installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or...

Страница 4: ...ed Leveling legs 4 Tools needed for gas installations 8 203 mm or 10 254 mm pipe wrench 8 203 mm or 10 254 mm adjustable wrench for gas connections Pipe joint compound resistant to propane gas Utility...

Страница 5: ...floor If using a pedestal you will need 18 460 mm to bottom of dryer The dryer must not be installed or stored in an area where it will be exposed to water and or weather IMPORTANT Do not operate ins...

Страница 6: ...only For steam models only inlet hose must not be kinked Installation Clearances For each arrangement consider allowing more space for ease of installation and servicing spacing for companion applian...

Страница 7: ...nch circuit Do not have a fuse in the neutral or grounding circuit Do not use an extension cord If codes permit and a separate ground wire is used it is recommended that a qualified electrician determ...

Страница 8: ...lt in a risk of electric shock Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded Do not modify the plug provide...

Страница 9: ...pping D 1 2 NPT gas supply line E Gas shut off valve A B E D C GAS SUPPLY REQUIREMENTS WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely t...

Страница 10: ...PIPE The gas pipe that comes out through the rear of your dryer has a 3 8 male pipe thread INSTALL LEVELING LEGS To avoid damaging floor use a large flat piece of cardboard from dryer carton place und...

Страница 11: ...to Direct Wire Connection Power supply cord 3 wire receptacle NEMA Type 10 30R Go to Power Supply Cord Connection NOTE If local codes do not permit connection of a cabinet ground conductor to neutral...

Страница 12: ...ough to hold the two clamp sections C together Power supply cord 4 wire receptacle NEMA Type 14 30R Go to 4 Wire Power Supply Cord Connection on this page Power supply cord 3 wire receptacle NEMA Type...

Страница 13: ...cord under green external ground conductor screw A Tighten screw 3 Wire Power Supply Cord Connection Use where local codes permit connecting cabinet ground conductor to neutral wire 3 Connect remainin...

Страница 14: ...nnection on this page If your wiring looks like this 4 Wire Direct Wire Connection IMPORTANT A 4 wire connection is required for mobile homes and where local codes do not permit 3 wire connections 1 P...

Страница 15: ...r and tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 3 Wire Direct Wire Connection Use where...

Страница 16: ...eutral ground wire and neutral wire C E B 1 Prepare to connect neutral ground wire and neutral wire E B A 3 Connect remaining wires Install the correct strain relief for your electrical connection met...

Страница 17: ...n A 3 8 flexible gas connector B 3 8 dryer gas pipe C 3 8 to 3 8 pipe elbow D 3 8 pipe to flare adapter fitting 3 Open shut off valve Open shut off valve in supply line valve is open when handle is pa...

Страница 18: ...a building Only rigid or flexible metal vent shall be used for exhausting Only a 4 102 mm heavy metal exhaust vent and clamps may be used Do not use plastic or metal foil vent Rigid metal vent Recomm...

Страница 19: ...t 16 5 m 2 Rigid metal 44 ft 13 4 m 3 Rigid metal 35 ft 10 7 m 4 Rigid metal 27 ft 8 2 m Special provisions for mobile homes Exhaust vent must be securely fastened to a noncombustible portion of mobil...

Страница 20: ...fastening devices that extend into interior of vent to secure vent because they can catch lint To determine if your model has a long vent system refer to the type code located on the serial number pla...

Страница 21: ...se and replace with new rubber washer 2 Attach short hose and Y connector Attach 2 ft 0 6 m inlet hose to cold water faucet Screw on coupling by hand until it is seated on faucet Then attach Y connect...

Страница 22: ...or flexible gas line After dryer is in place remove corner posts and cardboard from under dryer 5 Attach long hose to dryer fill valve and tighten coupling Remove protective cap from water inlet valve...

Страница 23: ...ust q Read Dryer Use in your Use and Care Guide q If you live in a hard water area use of a water softener is recommended to control the buildup of scale through the water system in the dryer Over tim...

Страница 24: ...rs 2 Phillips screwdriver Min 8 203 mm long TORX T20 and T25 screwdrivers Tools needed 1 Disconnect wiring from door Using a Phillips screwdriver remove middle screw in hinge Disconnect wiring Tuck wi...

Страница 25: ...top and the thick section is at the bottom Using a T25 screwdriver remove the four screws securing the latch plate in place 4 Remove inner door from outer door Position the door with the inside of th...

Страница 26: ...iver remove the two screws securing the rotating assembly to the door 10 Reposition rotating assembly and tubing Reposition rotating assembly and tubing 180 to opposite side of the door 11 Rotate asse...

Страница 27: ...electrical wiring Pull the wire through the front panel opening before reinstalling the door Insert the tabs on the hinge into the mounting slot and slide down to engage the top tab Secure in place w...

Страница 28: ...here is a small release tab on each side of the door If the inner and outer door do not separate easily slide a credit card putty knife or similar flat object between the inner and outer doors at the...

Страница 29: ...with the 13 screws removed earlier 7 Reattach door to dryer Using a T25 screwdriver reinstall the four screws securing the door hinge to the dryer 5 Reinstall hinge and latch on opposite sides Using...

Страница 30: ...30 S CURIT DE LA S CHEUSE...

Страница 31: ...tre indiqu s Si un conduit de raccordement flexible est utilis sa longueur ne doit pas d passer 4 pi 121 9 cm Ne pas entreposer ou utiliser de l essence ou d autres vapeurs ou liquides inflammables pr...

Страница 32: ...lation d un nouveau conduit Pistolet calfeutrage et compos de calfeutrage pour l installation d un nouveau conduit d vacuation Tourne crou de 1 4 6 mm et 5 16 8 mm recommand Couteau Pieds de nivelleme...

Страница 33: ...ue Utiliser un ensemble de c ble d alimentation lectrique homologu UL marqu compatible avec les s cheuses L ensemble doit contenir Un c ble d alimentation lectrique homologu UL de 30 amp res 120 240 v...

Страница 34: ...coude Voir Exigences concernant l vacuation Vue lat rale DIMENSIONS DE LA S CHEUSE Vue de face Mesures approximatives Mesures approximatives 61 4 159 mm 297 8 759 mm 31 2 89 mm 53 4 146 mm 61 8 156 m...

Страница 35: ...de passage de l air sont acceptables Il faut aussi prendre en compte l espace requis entre les appareils voisins Distances de d gagement recommand es pour l installation s cheuse seulement Autres cri...

Страница 36: ...ment tous les codes et r glements locaux INSTRUCTIONS DE LIAISON LA TERRE CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT Le raccordement incorrect de cet appareil au conducteur de liaison la terre peut susc...

Страница 37: ...mprendre un connecteur obtur filetage NPT de 1 8 ou plus accessible pour le raccordement de l instrument de mesure imm diatement en amont de la connexion d alimentation en gaz de la s cheuse Voir l il...

Страница 38: ...Faire glisser la s cheuse sur les corni res jusqu ce qu elle soit proche de son emplacement final Laisser suffisamment d espace pour connecter le conduit d vacuation 1 Pr parer la s cheuse pour les pi...

Страница 39: ...A Raccord de gaz flexible de 3 8 B Conduit de la s cheuse de 3 8 C Coude de canalisation de 3 8 x 3 8 D Adaptateur de tuyau au joint conique de 3 8 3 Ouvrir le robinet d arr t Ouvrir le robinet d arr...

Страница 40: ...te lors de la conception de l ensemble du circuit d vacuation tel qu indiqu dans les Tableaux des syst mes d vacuation REMARQUE Lors de l utilisation d un syst me de d charge existant nettoyer et limi...

Страница 41: ...S cheuse B Raccord coud C Mur D Clapet d vacuation E Brides F Conduit d vacuation m tallique rigide ou souple G Longueur de conduit d vacuation n cessaire pour le raccordement des coudes H Bouche de d...

Страница 42: ...pe de code pour un mod le gaz est DALV NAT XXXXXXX XXX REMARQUE Pour des syst mes d vacuation de grande longueur utiliser des clapets d vacuation persiennes ou de type bo te l vacuation sera meilleure...

Страница 43: ...uis fixer le raccord en Y l extr mit m le du tuyau d arriv e d eau de 2 pi 0 6 m Visser compl tement le raccord la main pour qu il soit scell au connecteur en Y 1 Fermer l eau froide retirer et rempla...

Страница 44: ...du connecteur en Y du robinet et des tuyaux d alimentation RACCORDEMENT DU CONDUIT D VACUATION 1 Raccorder le conduit d vacuation la bouche d vacuation 2 D placer la s cheuse son emplacement final l a...

Страница 45: ...on humide pour liminer toute trace de poussi re q Lire la section Utilisation de la s cheuse dans le Guide d utilisation et d entretien q Si l on r side dans une r gion o l eau est dure l emploi d un...

Страница 46: ...AVEC C BLAGE LECTRIQUE 3 D placer la g che de la porte l aide d un tournevis T25 retirer les deux vis fixant la g che de la porte au ch ssis de la porte de la s cheuse Faire pivoter la g che de 180 et...

Страница 47: ...n place la charni re Charni re 7 R installer le loquet sur l autre c t l aide d un tournevis T25 r installer la plaque du loquet sur le c t oppos par rapport celui d o il a t enlev en utilisant les qu...

Страница 48: ...s deux vis fixant l ensemble de rotation la porte 10 Replacer l ensemble de rotation et le tube Replacer l ensemble de rotation et le tube de 180 du c t oppos de la porte 11 Faire tourner la base de l...

Страница 49: ...lectrique Passer le c blage par l ouverture du panneau avant avant de r installer la porte Ins rer les onglets sur la charni re dans l encoche de montage et les faire glisser vers le bas pour engager...

Страница 50: ...gager la porte interne de la porte externe Positionner la porte de fa on ce que l int rieur de la porte soit orient vers le haut l aide d un tournevis Phillips retirer les 13 vis fixant la porte inte...

Страница 51: ...taller la porte sur la s cheuse l aide d un tournevis T25 r installer les quatre vis fixant la charni re de la porte la s cheuse 5 R installer la charni re et le loquet sur chaque c t l aide d un tour...

Страница 52: ...2018 All rights reserved Used under license in Canada Tous droits r serv s Utilis sous licence au Canada W11183136A W11183139A SP 04 18...

Отзывы: