4

DRYER DIMENSIONS

Back view:

6

1

/

2

"

(165 mm)

29

7

/

8

"*

(759 mm)

3

1

/

2

"*

(89 mm)

6

1

/

8

"*

(156 mm)

14

3

/

8

"

(365 mm)

3

/

4

"*

(18 mm)

NOTE:

 Most 

installations 

require a minimum 

of 5" (127 mm) 

clearance behind 

dryer for exhaust 

vent with elbow. 

See “Venting 

Requirements.”

LOCATION REQUIREMENTS

Check code requirements. Some codes limit, or do not permit, 

installing dryer in garages, closets, mobile homes, or sleeping 

quarters. Contact your local building inspector.

You will need:

 

A location allowing for proper exhaust installation. See  

“Venting Requirements.”

 

A separate 30 amp circuit.

 

If using power supply cord, a grounded electrical outlet  

located within 2 ft. (610 mm) of either side of dryer. See 

“Electrical Requirements.”

 

Floor must support dryer weight of 200 lbs. (90.7 kg). Also 

consider weight of companion appliance.

 

Cold water faucets located within 4 ft. (1.2 m) of the water  

fill valves, and water pressure of 20–120 psi (138–827 kPa).  

You may use the water supply for your washer using the 

supplied “Y” connector and a short hose (which you will  

need to purchase).

 

Level floor with maximum slope of 1" (25 mm) under entire 

dryer. If slope is greater than 1" (25 mm), install Extended  

Dryer Feet Kit, Part Number 279810. If not level, clothes  

may not tumble properly and automatic sensor cycles may  

not operate correctly.

 

For garage installation, place dryer at least 18" (460 mm) above 

floor. If using a pedestal, you will need 18" (460 mm) to bottom 

of dryer.

 

The dryer must not be installed or stored in an area where it will 

be exposed to water and/or weather.

IMPORTANT:

 Do not operate, install, or store dryer where  

it will be exposed to water, weather, or at temperatures below  

40° F (4° C). Lower temperatures may cause dryer not to  

shut off at end of automatic sensor cycles, resulting in longer  

drying times.

Installation Clearances

For each arrangement, consider allowing more space for ease  

of installation and servicing, spacing for companion appliances,  

and clearances for walls, doors, and floor moldings. Space  

must be large enough to allow door to fully open. Add spacing  

on all sides of dryer to reduce noise transfer. If a closet door  

or louvered door is installed, top and bottom air openings  

in door are required.

Check code requirements. Some codes limit, or do not permit, 

installation of the dryer in garages, closets, mobile homes, or 

sleeping quarters. Contact your local building inspector.

27"

(686 mm)

38

3

/

4

" Min.

(984 mm)

39" Max.

(990 mm)

Front view:

* Approx. measurement. 

Power supply 

cord/cable

Water inlet 

(Steam 

models only)

Vent

Side view:

Содержание MED5100DC

Страница 1: ...stem 15 CONNECT INLET HOSE STEAM MODEL ONLY 15 CONNECT VENT 16 LEVEL DRYER 17 COMPLETE INSTALLATION CHECKLIST 17 DOOR REVERSAL OPTIONAL 18 ELECTRIC DRYER INSTALLATION INSTRUCTIONS INSTALLATION NOTES D...

Страница 2: ...2 DRYER SAFETY IMPORTANT When discarding or storing your old clothes dryer remove the door...

Страница 3: ...ur installation Check local codes Check existing electrical supply and venting Read Electrical Requirements and Venting Requirements before purchasing parts If using a power supply cord Use a UL liste...

Страница 4: ...Feet Kit Part Number 279810 If not level clothes may not tumble properly and automatic sensor cycles may not operate correctly For garage installation place dryer at least 18 460 mm above floor If usi...

Страница 5: ...tral conductor white wire within the dryer If the dryer is installed with a 4 wire electrical supply connection the neutral ground conductor must be removed from the external ground connector green sc...

Страница 6: ...Flexible armored cable or nonmetallic sheathed copper cable with ground wire covered with flexible metallic conduit All current carrying wires must be insulated 10 gauge solid copper wire do not use...

Страница 7: ...re direct connection Go to Direct Wire Connection 4 wire direct connection Go to Direct Wire Connection Power supply cord 3 wire receptacle NEMA Type 10 30R Go to Power Supply Cord Connection NOTE If...

Страница 8: ...et and be in a horizontal position Do not further tighten strain relief screws at this point Remove the screws from a 3 4 19 mm UL listed strain relief UL marking on strain relief Put the tabs of the...

Страница 9: ...to Venting Requirements Connect remaining wires under outer terminal block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down...

Страница 10: ...the removable conduit connector A onto the strain relief threads and tighten securely Put direct wire cable through the strain relief The strain relief should have a tight fit with the dryer cabinet a...

Страница 11: ...l block screws hooks facing right Squeeze hooked ends together and tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to...

Страница 12: ...onnect neutral ground wire and neutral wire C E B 1 Prepare to connect neutral ground wire and neutral wire E B A 3 Connect remaining wires 4 Connect external ground wire G A Install the correct strai...

Страница 13: ...ust be fully extended and supported in final dryer location Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance Do not install in enclosed walls ceilings...

Страница 14: ...performance resulting in longer drying times and increased energy usage Optional exhaust installations This dryer can be converted to exhaust out the right side left side all models except long vent...

Страница 15: ...er faucet off and remove washer inlet hose Remove old rubber washer from inlet hose and replace with new rubber washer 3 Tighten couplings Using pliers tighten the couplings with additional two thirds...

Страница 16: ...r faucet Check that the water faucets are turned on CONNECT VENT 1 Connect vent to exhaust outlet 2 Move dryer to final location Using a 4 102 mm clamp connect vent to exhaust outlet in dryer If conne...

Страница 17: ...r drum interior thoroughly with a damp cloth to remove any dust q Read Dryer Use in your Use and Care Guide q For power supply cord installation plug into a grounded outlet For direct wire installatio...

Страница 18: ...et aside IMPORTANT If the protective film has not yet been removed from the dryer peel the film from the dryer door before proceeding Using a T25 screwdriver remove the 4 screws securing the door hing...

Страница 19: ...e 4 tabs on the trim ring indicated with arrows in the figure A above Then lift out the outer window and retainer up and off the trim ring and set aside B Fig A Fig B 5 Reverse outer window assembly U...

Страница 20: ...g plate and the 5 screws holding the hinge assembly in place Hinge Latch 6 Rotate and reassemble outer window assembly to trim ring With the edge with 2 notches at the top align the notches on the out...

Страница 21: ...r from dryer IMPORTANT If the protective film has not yet been removed from the dryer peel the film from the dryer door before proceeding Using a T25 screwdriver remove the 4 screws securing the door...

Страница 22: ...h plate and latch backing plate and the 5 screws holding the hinge assembly in place Hinge Latch 5 Reinstall hinge and latch on opposite sides Using a T25 screwdriver reinstall the latch plate and lat...

Страница 23: ...dryer door frame as shown 3 Remove inner door from outer door Position the door with the inside of the door facing up Using a Phillips screwdriver remove the 13 screws securing the inner door to the o...

Страница 24: ...yer 5 Reinstall hinge and latch on opposite sides Using a T25 screwdriver reinstall the latch plate and hinge assembly on the opposite sides from which they were removed Hinge Latch 4 Remove hinge and...

Отзывы: