background image

3

INSTALLATION REQUIREMENTS

TOOLS AND PARTS

Gather the required tools and parts before starting installation.

Tools needed:

Flat-blade screwdriver

#2 Phillips screwdriver

Adjustable wrench that 

opens to 1" (25 mm)  or 

hex-head socket wrench 

Wire stripper (direct wire 

installations)

Tin snips (new vent 

installations)

1/4" and 5/16" nut driver 

(recommended)

Utility knife 

 Level

Tape measure

Pliers

Caulking gun and 

compound (for installing 

new exhaust vent)

Leveling legs (4)

“Y” connector

Parts package is located in dryer drum. Check that all parts  

are included.

NOTE: 

Do not use leveling legs supplied with dryer if installing 

with a pedestal or a stack kit.

Additional parts may be required, depending on your installation. 

Check local codes. Check existing electrical supply and venting. 

Read “Electrical Requirements” and “Venting Requirements” 

before purchasing parts. 

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with  

clothes dryers. The kit should contain:

 

A UL listed 30-amp power supply cord, rated 120/240 volt 

minimum. The cord should be type SRD or SRDT and be  

at least 4 ft. (1.22 m) long. The wires that connect to  

the dryer must end in ring terminals or spade terminals  

with upturned ends.

 

A UL listed strain relief.

Optional Equipment: 

(Not supplied with dryer) 

Refer to your Use and Care Guide for information about 

accessories available for your dryer.

Parts supplied (all models): 

Parts supplied (steam models): 

2' (0.6 m) inlet hose

5' (1.52 m) inlet hose

Parts needed (steam models):

Parts needed: 

(Not supplied with dryer)

 

Vent clamps

 

Vent elbows and vent work

Rubber washer

Содержание MED5100DC

Страница 1: ...stem 15 CONNECT INLET HOSE STEAM MODEL ONLY 15 CONNECT VENT 16 LEVEL DRYER 17 COMPLETE INSTALLATION CHECKLIST 17 DOOR REVERSAL OPTIONAL 18 ELECTRIC DRYER INSTALLATION INSTRUCTIONS INSTALLATION NOTES D...

Страница 2: ...2 DRYER SAFETY IMPORTANT When discarding or storing your old clothes dryer remove the door...

Страница 3: ...ur installation Check local codes Check existing electrical supply and venting Read Electrical Requirements and Venting Requirements before purchasing parts If using a power supply cord Use a UL liste...

Страница 4: ...Feet Kit Part Number 279810 If not level clothes may not tumble properly and automatic sensor cycles may not operate correctly For garage installation place dryer at least 18 460 mm above floor If usi...

Страница 5: ...tral conductor white wire within the dryer If the dryer is installed with a 4 wire electrical supply connection the neutral ground conductor must be removed from the external ground connector green sc...

Страница 6: ...Flexible armored cable or nonmetallic sheathed copper cable with ground wire covered with flexible metallic conduit All current carrying wires must be insulated 10 gauge solid copper wire do not use...

Страница 7: ...re direct connection Go to Direct Wire Connection 4 wire direct connection Go to Direct Wire Connection Power supply cord 3 wire receptacle NEMA Type 10 30R Go to Power Supply Cord Connection NOTE If...

Страница 8: ...et and be in a horizontal position Do not further tighten strain relief screws at this point Remove the screws from a 3 4 19 mm UL listed strain relief UL marking on strain relief Put the tabs of the...

Страница 9: ...to Venting Requirements Connect remaining wires under outer terminal block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down...

Страница 10: ...the removable conduit connector A onto the strain relief threads and tighten securely Put direct wire cable through the strain relief The strain relief should have a tight fit with the dryer cabinet a...

Страница 11: ...l block screws hooks facing right Squeeze hooked ends together and tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to...

Страница 12: ...onnect neutral ground wire and neutral wire C E B 1 Prepare to connect neutral ground wire and neutral wire E B A 3 Connect remaining wires 4 Connect external ground wire G A Install the correct strai...

Страница 13: ...ust be fully extended and supported in final dryer location Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance Do not install in enclosed walls ceilings...

Страница 14: ...performance resulting in longer drying times and increased energy usage Optional exhaust installations This dryer can be converted to exhaust out the right side left side all models except long vent...

Страница 15: ...er faucet off and remove washer inlet hose Remove old rubber washer from inlet hose and replace with new rubber washer 3 Tighten couplings Using pliers tighten the couplings with additional two thirds...

Страница 16: ...r faucet Check that the water faucets are turned on CONNECT VENT 1 Connect vent to exhaust outlet 2 Move dryer to final location Using a 4 102 mm clamp connect vent to exhaust outlet in dryer If conne...

Страница 17: ...r drum interior thoroughly with a damp cloth to remove any dust q Read Dryer Use in your Use and Care Guide q For power supply cord installation plug into a grounded outlet For direct wire installatio...

Страница 18: ...et aside IMPORTANT If the protective film has not yet been removed from the dryer peel the film from the dryer door before proceeding Using a T25 screwdriver remove the 4 screws securing the door hing...

Страница 19: ...e 4 tabs on the trim ring indicated with arrows in the figure A above Then lift out the outer window and retainer up and off the trim ring and set aside B Fig A Fig B 5 Reverse outer window assembly U...

Страница 20: ...g plate and the 5 screws holding the hinge assembly in place Hinge Latch 6 Rotate and reassemble outer window assembly to trim ring With the edge with 2 notches at the top align the notches on the out...

Страница 21: ...r from dryer IMPORTANT If the protective film has not yet been removed from the dryer peel the film from the dryer door before proceeding Using a T25 screwdriver remove the 4 screws securing the door...

Страница 22: ...h plate and latch backing plate and the 5 screws holding the hinge assembly in place Hinge Latch 5 Reinstall hinge and latch on opposite sides Using a T25 screwdriver reinstall the latch plate and lat...

Страница 23: ...dryer door frame as shown 3 Remove inner door from outer door Position the door with the inside of the door facing up Using a Phillips screwdriver remove the 13 screws securing the inner door to the o...

Страница 24: ...yer 5 Reinstall hinge and latch on opposite sides Using a T25 screwdriver reinstall the latch plate and hinge assembly on the opposite sides from which they were removed Hinge Latch 4 Remove hinge and...

Отзывы: