background image

14

MULTIPLE DRYER (COMMON) VENTING

If it is not feasible to provide separate exhaust ducts for each dryer, ducts for individual dryers may be channeled
into a common main duct.  Each dryer is provided with a back draft damper.  The individual ducts should enter
the bottom or side of the main duct at an angle not more than 45° in the direction of the airflow.

The main common duct may be any shape as long as the minimum cross-sectional area is provided.  The main
duct 

should be

 tapered with the diameter increasing before each individual 8-inch (20.32 cm) duct is added

(refer to 

Illus. C

 for horizontal venting and 

Illus. D

 for vertical venting).

IMPORTANT:

No more than four (4) dryers maximum 

should be

 connected to one (1) main

common duct with a vertical run.

NOTE:

Distance between dryer single ducts being connected to the main common duct 

must be

 a

minimum of 34-1/4” (87 cm) dryer width.

Ductwork 

should be

 laid out in such a manner where allowances are made at rear area of the

dryer for removal of rear service panels or guards.

The

 illustrations

 on 

page 15

 show the minimum cross section area for multiple dryer venting.  These figures

must be

 increased in proportion if the main duct run from the last dryer to where it exhausts has numerous

elbows or is unusually long.

IMPORTANT:

For extended ductwork runs, the cross section area of the duct can only be increased
to an extent.  For extended ductwork runs, a professional heating, ventilating, and
air-conditioning (HVAC) firm 

should be 

consulted for proper venting information.

Refer to 

page 15

 for 

Multiple Dryer Horizontal Venting and Vertical Venting

 examples/illustrations.

IMPORTANT:

Exhaust back pressure measured by a manometer at the dryer exhaust duct area 

must

be

 no less than 0 and 

must not exceed

 0.3 inches (0.74 mb) of water column

(W.C.).

Содержание MDG50MNVWW

Страница 1: ...n Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent tre assur s par un installateur ou un...

Страница 2: ...ications colors and material and to change or discontinue models The illustrations included in this manual may not depict your particular dryer exactly Important For your convenience log the following...

Страница 3: ...disabled IMPORTANT YOUMUSTDISCONNECTANDLOCKOUTTHEELECTRICSUPPLYANDTHEGAS SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINETOALLOWACCESSFORCLEANING ADJUSTING INSTALLATION OR TESTING OF A...

Страница 4: ...cluded with the dryer WARNING DRYER MUST NEVER BE OPERATEDWITHOUTTHE LINTFILTER SCREEN IN PLACE EVENIFANEXTERNALLINTCOLLECTIONSYSTEMISUSED Dryer must not be installed or stored in an area where it wil...

Страница 5: ...equirements 9 D FreshAirSupplyRequirements 10 E ExhaustRequirements 11 F ElectricalInformation 16 G GasInformation 19 H Preparation For Operation Start Up 23 I PreoperationalTests 24 J PreoperationalI...

Страница 6: ...D LintDrawerRemoval 31 SECTION VII DATA LABEL INFORMATION 32 SECTION VIII PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 33 SECTION IX MANUAL RESET BURNER HI LIMIT INSTRUCTIONS 36 A Phase 7...

Страница 7: ...h c DO NOT use any phone in your building d Clear the room building or area of ALL occupants e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions f If yo...

Страница 8: ...ryer door switch lint drawer switch or heat safety circuit ever be disabled WARNING PERSONALINJURYOR FIRE COULD RESULT SHOULD THE DRYER DOOR SWITCH LINT DRAWER SWITCH OR HEAT SAFETYCIRCUIT EVER BE DIS...

Страница 9: ...BASKET TUMBLER DEPTH 37 1 2 95 3 cm BASKET TUMBLER MOTOR 3 4 hp 0 560 kW DOOR OPENING DIAMETER 21 1 2 54 61 cm BASKET TUMBLER VOLUME 18 3 cu ft 0 518 cu m DRYERS PER 20 40 CONTAINER 10 20 DRYERS PER...

Страница 10: ...6 NOTE Manufacturerreservestherighttomakechangesinspecificationsatanytimewithoutnoticeor obligation Specifications...

Страница 11: ...er IMPORTANT Dryer must be transported and handled in an upright position at ALLtimes The dryer can be moved to its final location while still attached to the skid or with the skid removed To unskid t...

Страница 12: ...h Air Supply Requirements in Section D 5 Clearance provisions must be made from combustible construction as noted in this manual refer to Dryer Enclosure Requirements in Section C 6 Provisions must be...

Страница 13: ...required providing no sprinkler is located above the dryer For steam dryers or if a sprinkler is located above the dryer 18 inches 45 72 cm is required D Dryer should be positioned 12 inches 30 48 cm...

Страница 14: ...ributed equally to the dryers The dryer must be installed with provisions for adequate combustion and make up air supply EXAMPLE For a bank of eight 8 dryers two 2 unrestricted openings measuring 3 fe...

Страница 15: ...to which it is connected ALL ductwork joints must be taped to prevent moisture and lint from escaping into the building Additionally inspection doors should be installed at strategic points in the ex...

Страница 16: ...over 20 feet 6 1 meters a minimum size of 10 inches 25 4 cm must be used HORIZONTAL VENTING When a single 8 inch 20 32 cm horizontal vent is used the ductwork to the outlet cannot exceed 20 feet 6 1 m...

Страница 17: ...elbows used exceeds the above noted specifications the cross sectional area of the ductwork must be increased in proportion to the number of elbows or duct run added IMPORTANT For extended ductwork r...

Страница 18: ...s being connected to the main common ductmust be a minimumof34 1 4 87cm dryerwidth Ductwork should be laid out in such a manner where allowances are made at rear area of the dryer for removal of rear...

Страница 19: ...15 HORIZONTAL VENTING Illus C VERTICAL VENTING Illus D...

Страница 20: ...protected branch circuit The dryer must be connected with copper wire only DO NOT use aluminum wire which could cause a fire hazard The copper conductor wire cable must be of proper ampacity and insul...

Страница 21: ...ipe The grounded cold water pipe must have metal to metal connection ALL the way to the electrical ground If there are any nonmetallic interruptions such as a meter pump plastic rubber or other insula...

Страница 22: ...ses a strain relief must be installed where the wiring enters the dryer IMPORTANT Aseparate protected circuit must be provided to each dryer Single Phase 1 Wiring Connections Hookup The electrical inp...

Страница 23: ...n cause irreparable damage to the gas valve which willVOIDTHEWARRANTY WARNING FIRE OR EXPLOSION COULD RESULT DUE TO FAILURE OF ISOLATINGOR DISCONNECTINGTHE GAS SUPPLYAS NOTED 1 Gas Supply The gas drye...

Страница 24: ...the gas pressure must be regulated upstream of the dryer The pressure measured at each gas valve pressure tap must be a consistent 10 5 inches 26 1 mb water column There is no regulator or regulation...

Страница 25: ...iance Btus being supplied The dryer is provided with a 1 2 N P T inlet pipe connection extending out the back area of the burner box The minimum pipe size supply line to the dryer is 1 2 diameter For...

Страница 26: ...and safe operation A 1 8 N P T plugged tap accessible for a test gauge connection must be installed in the main gas supply line immediately upstream of each dryer IMPORTANT Pipe joint compounds that...

Страница 27: ...ted at the factory prior to shipping However each sail switch adjustment must be checked to ensure that this important safety control is functioning 5 Check bolts nuts screws terminals and fittings fo...

Страница 28: ...ignitions total of three 3 ignition attempts If there is no flame after the third ignitionattemptthemodulewilllockoutuntilitismanuallyreset Toresettheignitionsystem open and close the main door and r...

Страница 29: ...meaning no cycle in progress 2 Press the letter on the keyboard touch pad corresponding to the cycle desired i e key E to start rotate the dryer 3 L E D display will now show Cycle In Progress and Cy...

Страница 30: ...cated on the electronic timer as noted in the illustration below K SHUTDOWN INSTRUCTIONS If the dryer is to be shutdown taken out of service for a period of time the following must be performed 1 Disc...

Страница 31: ...acting the Maytag Co be sure to give them the correct model number and serialnumbersothatyourinquiryishandledinanexpeditiousmanner B PARTS Replacement parts should be purchased from the dealer from wh...

Страница 32: ...pleted and returned for each individual dryer NOTE Besuretoincludetheinstallationdatewhenreturningthewarrantycard s B WARRANTY For a copy of the manufacturer s commercial warranty covering your partic...

Страница 33: ...AND LIQUIDS NOTE Suggested time intervals shown are for average usage which is considered six 6 to eight 8 operational running hoursperday IMPORTANT Dryer produces combustible lint and must be exhaust...

Страница 34: ...setscrews grounding connections and nonpermanent gas connections unions shutoff valves and orifices Motor and drive belts should be examined Cracked or seriously frayed belts should be replaced Tighte...

Страница 35: ...r pull drawer out approximately halfway Rotate move lint drawer stop hinge refer to the illustration below downward and pull the drawer out IMPORTANT After replacing the lint drawer back into the drye...

Страница 36: ...er to gather information on your particular dryer 3 MANUFACTURINGCODE NUMBER The number issued by the manufacturer which describes ALL possible options on your particular model 4 TYPE OFHEAT This desc...

Страница 37: ...1 Upon completing installation of the replacement microprocessor controller computer board reestablish power to the dryer 2 Start the drying cycle by pressing any temperature selection keys HI MED or...

Страница 38: ...croprocessor controller computer board reestablish power to the dryer 2 Start the drying cycle by pressing any of the preset cycles in letters A F 3 Verify that the applicable indicator lights on the...

Страница 39: ...operation No L E D indicator indicates a power or an internal failure has occurred 3 For Models with DSI Module Type II Theory of Operation Start the drying cycle When the gas burner ignites within th...

Страница 40: ...re has dropped below 100 F 38 C The clear stop button on the Phase 7 keyboard touch pad must be pressed to clear the error condition The open burner hi limit must be reset manually prior to the start...

Страница 41: ...insorreignites While the water jet s are activated the basket tumbler will jog to move the water throughout the load The microprocessor will display that the system was activated and will continue to...

Страница 42: ...supplied with a minimum water pipe size of 1 2 and be provided with 40 psi 20 psi 2 75 bar 1 37 bar of pressure For use of optional manual bypass a second source with the same piping and pressure requ...

Страница 43: ...ne coupling must be used in an effort to avoid damaging the electric water solenoid valve NOTE The 3 4 11 5 NH is a standard hose coupling screw thread It is not to be confused with 3 4 N P T The seal...

Страница 44: ...er or the water supply is located in an area where it will be exposed to cold freezing temperatures provisions must be made to protect these water lines from freezing WARNING If the water in the suppl...

Страница 45: ...of the temperature and the control will display S A F E SYSTEM WAS ACTIVATED If the temperature has dropped below trip point the control will turn off the water prior to 10 minutes SYSTEM RESET After...

Страница 46: ...corrected the control will continue to monitor the condition for 1 minute before exiting S A F E SYSTEM DISABLED mode SHORTED WATER VALVE This message indicates that the water valve is shorted or that...

Страница 47: ..._____________________________________________________________________________________________________ __________________________________________________________________________________________________...

Страница 48: ...Part No 113308 6 06 26 08 0...

Отзывы: