6. Steam Damper Piston (Flow Control) Operation Adjustment
Although the damper operation was tested and adjusted prior to shipping at 80 psi, steam damper operation
must be
checked before the dryer is put into operation. Refer to the illustration above for correct steam
damper operation. If damper air adjustment is necessary, locate flow control valve and make necessary
adjustments as noted below.