FOR YOUR INFORMATION

START UP CONDITIONS

CONDENSATE

Whenever the water heater is filled with cold water, some condensate
will form while the burner is on. A water heater may appear to be leaking
when in fact the water is condensate. This usually happens when:

a. A new water heater is filled with cold water for the first time.
b. Burning gas produces water vapor in water heaters, particularly

high efficiency models where flue temperatures are lower.

c. Large amounts of hot water are used in a short time and the refill

water in the tank is very cold.

Moisture from the products of combustion condense on the cooler tank
surfaces and form drops of water which may fall onto the burner or
other hot surfaces to produce a “sizzling” or “frying” noise.

Because of the suddenness and amount of water, condensate water
may be diagnosed as a “tank leak”. After the water in the tank warms
up (about 1-2 hours), the condition should disappear.

Do not assume the water heater is leaking until there has been enough
time for the water in the tank to warm up.

An undersized water heater will cause more condensation. The water
heater must be sized properly to meet the family’s demands for hot
water including dishwashers, washing machines and shower heads.

Excessive condensate may be noticed during the winter and early
spring months when incoming water temperatures are at their lowest.

Good venting is essential for a gas fired water heater to operate properly
as well as to carry away products of combustion and water vapor.

SMOKE/ODOR

It is not uncommon to experience a small amount of smoke and odor
during the initial start-up. This is due to burning off of oil from metal
parts, and will disappear in a short while.

THERMAL EXPANSION

Water supply systems may, because of such events as high line
pressure, frequent cut-offs, the effects of water hammer among
others, have installed devices such as pressure reducing valves, check
valves, back flow preventers, etc. to control these types of problems.
When these devices are not equipped with an internal by-pass, and no
other measures are taken, the devices cause the water system to be
closed. As water is heated, it expands (thermal expansion) and closed
systems do not allow for the expansion of heated water.

The water within the water tank expands as it is heated and increases the
pressure of the water system. If the relieving point of the water heater’s
temperature-pressure relief valve is reached, the valve will release the excess
pressure. 

The temperature-pressure relief valve is not intended

for the constant relief of thermal expansion. 

This is an unacceptable

condition and must be corrected. It is recommended that any devices installed
which could create a closed system have a by-pass and/or the system have
an expansion tank or device to relieve the pressure built by thermal expansion
in the water system. Expansion tanks are available for ordering through the
Maytag Customer Service Center (1-800-788-8899). Contact the local plumbing
inspector, water supplier and/or 

call Maytag Customer Service at 1-800-

788-8899 for assistance in controlling these situations

.

STRANGE SOUNDS

Possible noises due to expansion and contraction of some metal parts
during periods of heat-up and cool-down do not necessarily represent
harmful or dangerous conditions.

Condensation causes sizzling and popping within the burner area during
heating and cooling periods and should be considered normal. See
“Condensate” in this section.

OPERATIONAL CONDITIONS

SMELLY WATER

In each water heater there is installed at least one anode rod (see
parts section) for corrosion protection of the tank. Certain water
conditions will cause a reaction between this rod and the water. The
most common complaint associated with the anode rod is one of a
“rotten egg smell” in the hot water. The smell is a result of four factors
which must all be present for the odor to develop:

a. A concentration of sulfate in the supply water.
b. Little or no dissolved oxygen in the water.
c. A sulfate reducing bacteria which has accumulated within the water

heater (this harmless bacteria is nontoxic to humans).

d. An excess of active hydrogen in the tank. This is caused by the

corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater
models by replacing the anode(s) with one of less active material, and
then chlorinating the water heater tank and all water lines. Contact

Maytag Customer Service (1-800-788-8899)

 for further information

concerning Anode Replacement Kit #9001453 and this chlorination
treatment. Anode replacement and chlorination of the tank are not
covered by the water heater’s limited warranty.

If the smelly water persists after the anode replacement and chlorination
treatment, we can only suggest that chlorination or aeration of the
water supply be considered to eliminate the water problem.

Do not remove the anode leaving the tank unprotected. By
doing so, all warranty on the water heater tank is voided.

“AIR” IN HOT WATER FAUCETS

HYDROGEN GAS: Hydrogen gas can be produced in a hot water system
that has not been used for a long period of time (generally two weeks or
more). Hydrogen gas is extremely flammable and explosive. To prevent
the possibility of injury under these conditions, we recommend the hot
water faucet, located farthest away, be opened for several minutes
before any electrical appliances which are connected to the hot water
system are used (such as a dishwasher or washing machine). If hydrogen
gas is present, there will probably be an unusual sound similar to air
escaping through the pipe as the hot water faucet is opened. There must
be no smoking or open flame near the faucet at the time it is open.

HIGH WATER TEMPERATURE SHUT OFF SYSTEM

This water heater is equipped with an automatic gas shut-off system. This
system works when high water temperatures are present. Turn “OFF” the
entire gas supply to the water heater. The high temperature shut-off is built
into the gas control valve. It is non-resettable. If the high temperature shut-off
activates, the gas control valve must be replaced. Contact your gas supplier
or 

Maytag Customer Service (1-800-788-8899)

.

Содержание HV640HBVIT

Страница 1: ... GUIDE Series Six Model Numbers HV640YBVIT HV650YBVIT HV640HBVIT HV650HBVIT For Your Safety AN ODORANT ISADDEDTO THE GAS USED BYTHIS WATER HEATER C3 Technology Gas Water Heaters meet the new ANSI Z21 10 1 standard that deals with the accidental or unintended ignition of flammable vapors such as those emitted by gasoline Safety Instructions Installation Operation Care and Maintenance Troubleshootin...

Страница 2: ...g Customer Service Center The Maytag Customer Service Center has the ability equivalent to a licensed tradesman in the fields of plumbing air supply venting and gas supply including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fired water heaters The Service Center also has a thorough understanding of this instruction manual an...

Страница 3: ...3 SAFETY PRECAUTIONS ...

Страница 4: ...Blower Assembly Installation 16 Vent Connections to Blower Assembly 17 Venting and Installation 17 18 Condensation 18 Maximum Vent Lengths 18 Venting 19 Vent Terminal Installation 19 20 Vertical Vent Through Roof 20 Vertical Vent Restrictions 20 Vent Pipe Preparation 21 22 OPERATING INSTRUCTIONS 23 24 Lighting and Operating Label 23 Temperature Regulation 24 FOR YOUR INFORMATION 25 Start Up Condit...

Страница 5: ...arnings and all instructions are essential to the proper operation of the water heater and your safety Since we cannot put everything on the first few pages READ THE ENTIRE MANUAL BEFORE ATTEMPTINGTOINSTALLOROPERATETHEWATERHEATER 2 The installation must conform with these instructions and the local code authority having jurisdiction In the absence of local codes installationsshallcomplywiththeNati...

Страница 6: ...ontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEPCLEAR OFALLOBSTRUCTIONS INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carbon monoxide detectors and signa...

Страница 7: ...LESSAND 28 711mm DIAMETER PARTNO 66001012 FORWATERHEATERS HAVINGADIAMETER 26 660 mm OR LESS Tools You may or may not need all these tools depending on your type of installation These tools can be purchased at your local hardware store Pipe Wrenches 2 14 356 mm Screwdriver Tin Snips 6 1 82 m Tape or Folding Ruler Garden Hose Drill Pipe Dope or Teflon Tape Additional Tools Needed When Sweat Solderin...

Страница 8: ...alve U Ground Joint Union V Drip Leg Sediment Trap W Drain Valve X Gas Valve Thermostat Y Drain Pan Z Air Intake Screen Base Pan AA Inner Door BB Outer Door CC HSI Burner Assembly DD Air Intake Screen Blower Assembly EE FV Sensor Assembly NATURAL HOT SURFACE IGNITER MAIN BURNER HOT SURFACE IGNITOR SENSOR PROPANE HOT SURFACE IGNITER MAIN BURNER TEMPERATURE INDICATORS TEMPERATUREADJUSTMENT BUTTONS H...

Страница 9: ...ts into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must takespecialprecautions Inadditiontousingthelowestpossibletemperature setting that satisfies your hot water needs a means such as a Mixing Valve shall be used at the hot water taps used by these people or at the water heater Mixing valves are available at plu...

Страница 10: ... can be lifted off after any screw or other attached devices are removed Make sure existing vent complies with maximum and minimum vent lengths on page18 6 If you have copper piping to the water heater the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater see Figure 7 This will avoid cutting off pipes too short Additional cu...

Страница 11: ...n alarm or turn off the incoming water to the water heater when leakage is detected Sensors mounted in the drain pan that turn off the water supply to the entire home when water is detected in the drain pan Water supply shut off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heater Devices that will turn off the gas ...

Страница 12: ... meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements making an insulation blanket unnecessary Should you choose to apply an insulation blanket to this heater you should follow these instructions For identification of components mentioned below see Figure 1 Failure to follow these instructions can restrict the air flow r...

Страница 13: ...re inch per 4 000 Btu per hour 5 5 cm2 kW of total input rating of all equipment in the enclosure see Figure 13 FIGURE13 2 When communicating with the outdoors through vertical ducts each opening shall have a minimum free area of 1 square inch per 4 000 Btu per hour 5 5 cm2 kW of total input rating of all equipment in the enclosure see Figure 14 3 When communicating with the outdoors through horiz...

Страница 14: ...r state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as a mixing valve shall be used at the hot water taps used by these people or at the water heater see Figure 2 Valves for reducing point of use temperature by mixing cold and hot w...

Страница 15: ...be installed directly into the fitting of the water heater designed for the relief valve Position the valve downward and provide tubing so that any discharge will exit only within 6 inches 15 2 cm above or at any distance below the structural floor Be certain that no contact is made with any live electrical part The discharge opening must not be blocked or reduced in size under any circumstances E...

Страница 16: ...lution and wipe dry Water heaters covered in this manual have been tested and approved for installation at elevations up to 7 700 feet 2 347 m above sea level When installed at elevations above 7 700 feet 2 347 m input rating should be reduced at the rate of 4 percent for each 1 000 feet 305 m above sea level which requires replacement of the burner orifice in accordancewithNationalFuelGasCodeANSI...

Страница 17: ...ntedwaterheatercomeswiththeblowerassemblyinstalled 2 After the unit is set in place make sure the blower assembly is still mounted securely and the air intake screen of the blower assembly is installed in the dilution air opening Also make sure the drain port of the rubber boot vent adapter is capped off Lastly make sure there is no damage to the blower 3 Make sure there is no packing material in ...

Страница 18: ...r heater to an existing vent or chimney It must be vented separately from all other appliances Nonmetallic vent may be used if it has Heat Deflection Temperature HDT 66 psi or 455 kPa of at least 157 F or 69 C Typical nonmetallic vent materials meeting this requirement are PVC Schedule 40 ASTM D 1785 Coex Cellular Core Schedule 40 ASTM F 441 CPVC Schedule 40 ASTM D 2846 ABS Schedule 40 ASTM D 2661...

Страница 19: ...cur in all installations of power vented water heaters but should be protected against on installations where it can form in the venting system Condensation in the venting system of power vented water heaters is dependent upon installation conditions including but not limited to ambient temperature and humidity of installationlocation ambienttemperatureandhumidityofventingspace vent discharge and ...

Страница 20: ...learances from combustible materials must be provided in accordance with information in this manual under FACTSTO CONSIDERABOUTTHE LOCATION and VENT TERMINAL INSTALLATIONS and with the National Fuel Gas Code and local codes VENT TERMINAL INSTALLATION 1 After the point of termination has been determined use the cover plate as a template to mark the hole for the vent pipe to insert throughthewall BE...

Страница 21: ... The wall flange is supplied for decorative purposes only and is not a requirement for the vent termination if not needed by the installer VERTICAL VENT THROUGH ROOF This unit is approved for venting through the roof with the type vent terminal that is included with the unit A proper flashing or BOOT should be used to seal the pipe where it exits the roof The total vent system should not exceed th...

Страница 22: ...hes 15 2 cm and above PRIMER It is recommended that Tetrahydrofuran THF be used to prepare the surfaces of pipe and fittings for solvent welding Do not use water rags gasoline or any other substitutes for cleaning PVC or CPVC surfaces Achemical cleaner such as MEK may be used CEMENT The cement should be a bodied cement of approximately 500 to 1600 centipoise viscosity containing 10 20 by weight vi...

Страница 23: ...tance and make a second mark as the primer and cement will most likely destroy your first one Apply primer to the surface of the pipe and fitting socket with a natural bristlebrush ThisprocesssoftensandpreparesthePVCorCPVCfor thesolventcementingstep Movequicklyandwithouthesitationtothe cementingprocedurewhilethesurfacesarestillwetwithprimer E Application of solvent cement Applythesolventcementeven...

Страница 24: ...uttons together and holding for 1 second Then press the COOLER button until the WARM indicator light appears 2 Set the ON OFF switch on the blower control box to the OFF position 3 Turn off all electric power to the appliance if service is to be performed BEFORE OPERATING ENTIRE SYSTEM MUST BE FILLED WITH WATERANDAIR PURGED FROMALL LINES 1 STOP Read the safety information above on this label 2 Set...

Страница 25: ...ng authority The water heater should be located in an area where the general public does not have access The water temperature setting was factory set at the lowest temperature Pressingthe COOLER buttondecreasestemperature and pressing the HOTTER button increases the temperature Setting the water heater temperature at 120 F 49 C Approx mark on temperature setting of gas valve will reduce the risk ...

Страница 26: ...9 Contactthelocalplumbing inspector watersupplierand orcallMaytagCustomerServiceat1 800 788 8899 for assistance in controlling these situations STRANGESOUNDS Possible noises due to expansion and contraction of some metal parts during periods of heat up and cool down do not necessarily represent harmful or dangerous conditions Condensation causes sizzling and popping within the burner area during h...

Страница 27: ...etoperation and cause no excessive flame lifting from the burner ports If the proper flame characteristics are not evident see Figure 28 make sure that the flow of combustion and ventilation air is not blocked on the Air Intake Screen at the base of the water heater see Figure 29 the Lint screen on the blower assembly see Figure 1 and in the venting system Youshouldalsocheckforsooting Sootisnotnor...

Страница 28: ...veacheck valveinstalledinthewaterlineorawatermeterwithacheckvalve Consult yourlocalwatersupplierorMaytagCustomerService 1 800 788 8899 for furtherinformation Donotplugthetemperature pressurereliefvalve DRAINING The water heater should be drained if being shut down during freezing temperatures Also periodic draining and cleaning of sediment from the tank may be necessary 1 Set the blower switch to ...

Страница 29: ...mbly D Small amounts of water from temperature pressure relief valve may be due to thermal expansion or high water pressure in your area E The temperature pressure relief valve may be leaking at the tank fitting F Water from a drain valve may be due to the valve being slightly opened G The drain valve may be leaking at the tank fitting H Combustion products contain water vapor which can condense o...

Страница 30: ...surface ignitor not positioned correctly 3 Low voltage to the water heater 4 Electric polarity to unit is incorrect test and correct Problem in the gas valve driver circuit 1 Turn power to the water heater off for 10 seconds and the back on 2 Replace gas control valve Problem with the internal circuit 1 Turn power to the water heater off for 10 seconds and then back on 2 Replace gas control valve ...

Страница 31: ...hese guidelines should be used by a qualified Maytag Customer Service CenterAgent Call the Maytag Customer Service Center at 1 800 788 8899 for assistance Inform the associate that this is a Flammable Vapor Ignition Resistant Product ...

Страница 32: ...1513 10 BlowerAssembly TBD TBD TBD TBD 11 Air Intake Screen Base Pan 66001503 66001503 66001503 66001503 12 InletTube 66001646 66001307 66001646 66001307 13 Gas Control Valve TBD TBD TBD TBD 14 Drain Valve 66001016 66001016 66001016 66001016 15 Drain Valve Washer 66001021 66001021 66001021 66001021 16 Outer Door TBD TBD TBD TBD 17 Anode Rod TBD 66001832 TBD 66001832 18 Temperature Pressure Relief ...

Страница 33: ...33 NOTES ...

Страница 34: ...34 NOTES ...

Страница 35: ...35 NOTES ...

Страница 36: ...eak occurs in the tank a new water heater of the closest capacity and quality then available will be replaced free of charge for the water heater with the owner paying all other costs including labor mileage and transportation If the water heater is subjected to commercial institutional industrial or non residential use the above warranty coverage for the tanks that are proved to be defective in m...

Отзывы: