DD01*
RECTANGULAR INDENTATION
ON BOTTOM OF DD01*
½”
CENTER OF MAGNET
(IN HOLDER)
MUST BE ½” FROM THE
SENSOR MOUNTING PLATE
SENSOR
MOUNTING
PLATE
to
IMPORTANT NOTE: When properly installed, the rectangu-
lar indentation on the bottom of the DD01* will line up with
the center of the magnet.
Choose magnet position A, B or C to align the magnet 1/2”
from the back of the DD01A*.
Binding of RF Devices
DO NOT ATTEMPT TO BIND
MORE THAN ONE ROOM AT A TIME AT THE
SAME PROPERTY!!!
RF TRANSMITS THROUGH WALLS.
The wireless devices (DS01* and or DD01*) must be bound to
the PTAC DT01* control for proper in-room communication.
Ensure the unit is powered but in the OFF position.
NOTE:
Both the DS01* and the DD01* must be bound to
the PTAC unit during the same “learn” operation.
If you need to rebind one device - then you must rebind both
devices during the same learn mode event.
All must be bound at one time.
1.
Press and hold off button on the PTAC until appears.
2.
Press and then immediately release the white tactile but-
ton on the back of the DS01* thermostat.
should now
be displayed on the PTAC LED display. If
does not
show on the display in 1-2 seconds, then press and re-
lease the white button a second time. Skip this step if
there is no thermostat.
3.
Press and then immediately release the white tactile but-
ton on the back of the DD01* motion sensor.
or
should now be displayed on the PTAC LED display.
If
or
does not show on the display in 1-2 seconds,
then press and release the white button a second time.
NOTE:
If both a DD01* and a DS01* are being bound, then
the display will show
.
Skip if there is no motion sensor.
4.
Press “OFF” on the PTAC touchpad to exit the binding
sequence.
5.
Snap thermostat onto thermostat mounting plate.
6.
Snap motion sensor onto motion sensor mounting plate.
7.
Configure the device or devices that were bound. See the
next section for configuration choices.
NOTE: If a wireless device is replaced or added, all devices
(including those previously bound) will need to be bound/re-
bound to the unit. See directions above.
CONFIGURATION SETTINGS
The PTAC control will automatically self-configure to work with
the wall thermostat (DS01* Kit) if installed. The PTAC control
will automatically self-configure to activate pre-configured en-
ergy management routine when the DD01* is installed and bound
to the PTAC. Additionally, the setback times and setback tem-
peratures can be changed using the configuration settings. If
you are using DP01* Front Desk Platform, the PTAC control
will need to be configured to identify its room number place-
ment.
STANDARD AND DS01A CONFIGURATION
To enter configuration feature mode:
Press
and
continue to hold
the up and down
arrow
keys and quickly
press
the
OFF
key
twice
within a two (2) second time frame
.
(On software
versions 2.1 or lower - C1 will now be displayed. On ver-
sion 2.5 or higher - you will see “ - - “ displayed.)
Once
you are in the configuration program, you can use the
HEAT button to move UP the various configuration set-
tings or the COOL button to move DOWN the configura-
tion settings. The + or - keys will move up or down the
selectable codes that you can change for each configu-
ration setting. Ensure that you are in the proper configu-
ration setting before pressing the + or - key as you may
accidentally change a setting that you did not intent to
change.
The display will alternate between displaying the feature
code
and the option code
0
(factory default setting)
.
If in version 2.5 or higher - press the HEAT button one
time to get into C1 mode and then the display will alter-
nate between C1 and 0 - the factory default. If an RF
DS01* has been bound to the unit the display will alter-
nate between C1 and rE.
The lower right dot on the dis-
play will flash.
PROPER INSTALLATION