15

SUBCOOLING FORMULA = SAT. LIQUID TEMP.

- LIQUID LINE TEMP.

SUCTION

PRESSURE

SATURATED

SUCTION 

TEMPERATURE

ºF

LIQUID

PRESSURE

SATURATED

LIQUID 

TEMPERATURE

ºF

PSIG  

R-410A  

PSIG  

R-410A  

50

1

200

70

52

3

210

73

54

4

220

76

56

6

225

78

58

7

235

80

60

8

245

83

62

10

255

85

64

11

265

88

66

13

275

90

68

14

285

92

70

15

295

95

72

16

305

97

74

17

325

101

76

19

355

108

78

20

375

112

80

21

405

118

85

24

415

119

90

26

425

121

95

29

435

123

100

31

445

125

110

36

475

130

120

41

500

134

130

45

525

138

140

49

550

142

150

53

575

145

160

56

600

149

170

60

625

152

SATURATED

SUCTION PRESSURE

 TEMPERATURE CHART

SATURATED

LIQUID PRESSURE

 TEMPERATURE CHART

Table 6

Suction Pressure            Liquid Pressure

Temperature  (R-410A)    Temperature (R-410A)

ELECTRIC HEAT INSTALLATION 

Heater Kit 

NOTE: A separate power supply is required for the 

HKR/HKP heater kits.

Refer to the Heat Kit Electrical Data (Blower Only, Heat 

Mode) specification table below for heater kit match up 

and heater kit electrical data information. See specific kit 

installation manual for installation instructions.

This series of electric cooling and heat pump package 

equipment is designed to accept a field installed electric 

heat kit. The unit is equipped to easily install the HKR/HKP 

Series Electric Heat Kit. Full Installation Instructions are 

included in this kit. Please use this document for guidance 

in field equipping the package unit with electric heat.

Choose the heat kit that fits the application for the specific 

installation. Permanently mark the unit’s nameplate 

with the model being installed. High and low voltage 

connections are detailed in the heat kit instructions.

Indoor Blower motor speed tap selection may need to be 

modified to accommodate normal continuous operation to 

prevent a nuisance trip. 

See following table.

*PCH3 / *PHH3

Indoor Blower motor speed tap selection may need to be 

modified to accommodate normal continuous operation to 

prevent a nuisance trip. See following table.

5

8

10

15

20

[*PCH/*PHH]32441**

T3

T3

T3

NA

NA

[*PCH/*PHH]33041**

T3

T3

T3

T5

NA

[*PCH/*PHH]33641**

T3

T3

T3

T5

NA

[*PCH/*PHH]34241**

T3

T3

T3

T5

T5

[*PCH/*PHH]34841**

T3

T3

T3

T5

T3

[GPCH/*PHH]36041**

T3

T3

T3

T5

T3

*PCH3[24-48]/*PHH3[24-60]41 Models (0 - 0.5 E.S.P.)

Electric Heat KW

Unit Model Number

5

8

10

15

20

[*PCH/*PHH]32441**

T5

T5

T5

T5

NA

[*PCH/*PHH]33041**

T5

T5

T5

T5

NA

[*PCH/*PHH]33641**

T5

T5

T5

T5

NA

[*PCH/*PHH]34241**

T5

T5

T5

T5

NA

[*PCH/*PHH]34841**

T5

T5

T5

T5

NA

[GPCH/*PHH]36041**

T5

T5

T5

T5

NA

*PCH3[24-48]/*PHH3[24-60]41 Models (0.5 -0.8 E.S.P.)

Unit Model Number

Electric Heat KW

T1 - Fan Only, T2 - Normal Speed Cooling

T3 - Normal Speed Heating

T4 - High Speed Cooling, T5 - High Speed Cooling

Содержание Amana APCH32441

Страница 1: ...or repair the equipment specified in this manual without proper training may result in product damage property damage personal injury or death WARNING RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION All...

Страница 2: ...y look the location over both the inside and outside of home Note any potential obstacles or problems that might be encountered as noted in this manual Choose a more suitable location if necessary IMP...

Страница 3: ...inal tons of cooling Optional field installed heat kits are available in 5 8 10 15 and 20 KW The units can be easily installed in manufactured or modular homes with existing high static duct work The...

Страница 4: ...letely unobstructed If units are to be located under an overhang there should be a minimum of 48 clearance and provisions made to deflect the warm discharge air out from the overhang Location Consider...

Страница 5: ...ver the unit to prevent damage to the cabinet by the lift cables Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport Remove wood struts moun...

Страница 6: ...lenum Application A suitable plenum or square duct must be constructed The duct cross sectional area should be determined by industry duct sizing manuals or air duct calculators On ductwork exposed to...

Страница 7: ...NFPA NO 70 1984 or latest edition by using ground lug in the control box DO NOT EXCEED THE MAXIMUM OVERCURRENT DEVICE SIZE SHOWN ON UNIT DATA PLATE Fuses or HACR type circuit breakers may be used wher...

Страница 8: ...er when servicing the unit WARNING HIGH VOLTAGE Disconnect all power before servicing or in stalling this unit Multiple power sources may be present Failure to do so may cause proper ty damage persona...

Страница 9: ...upplemental heat Normally a Defrost cycle will take only 2 3 minutes unless system is low on charge or outdoor conditions are severe windy and cold The defrost control also provides for a 3 minute off...

Страница 10: ...e heating requirement should there be a component failure of the heat pump such as a compressor or refrigerant leak etc Since the temperature of the liquid refrigerant in the outdoor coil on the heati...

Страница 11: ...ple type temperature test lead on the tube adjacent to the defrost control Insulate the lead point of contact 2 Check the temperature at which the control closes its contacts by lowering the temperatu...

Страница 12: ...or with a electronic control board ECM Motor The ECM motor provides many features not available on the traditional PSC motor These features include Improved Efficiency Constant CFM Soft Start and Stop...

Страница 13: ...ltage power wire typically the black lead to the thermostat R Red wire in control box 5 Secure the dehumidistat ground wire typically the green lead to the ground screw to the unit s sheet metal contr...

Страница 14: ...running on low stage with TXV application should have a subcooling and superheat within the range listed on the chart a If subcooling and superheat are low adjust TXV superheat then check subcooling N...

Страница 15: ...to easily install the HKR HKP Series Electric Heat Kit Full Installation Instructions are included in this kit Please use this document for guidance in field equipping the package unit with electric h...

Страница 16: ...Do not allow air entering the indoor coil to drop below 65 F Air below this temperature will cause low discharge pressure thus low suction pressure and excessive defrost cycling resulting in low heati...

Страница 17: ...88 1022 989 Watts 179 190 203 210 225 243 249 268 CFM 1758 1715 1674 1637 1596 1557 1518 1474 Watts 394 406 418 430 443 455 466 474 CFM 2002 1935 1885 1827 1767 1732 1669 1618 Watts 498 521 516 534 55...

Страница 18: ...gs for Single Two Stage Thermostat Speed Tap Switch 5 Switch 6 A OFF OFF B ON OFF C OFF ON D ON ON Cooling HP DIP Switch Settings CFM Switch 7 Switch 8 Plus 10 ON OFF Normal OFF OFF Minus 10 OFF ON Sp...

Страница 19: ...81 294 305 318 330 CFM 1736 1679 1638 1598 1558 1520 1484 1441 Watts 356 372 382 395 408 422 433 442 CFM 1337 1297 1218 1155 1118 1088 1022 989 Watts 179 190 203 210 225 243 249 268 CFM 1758 1715 1674...

Страница 20: ...t be within 10 of nameplate volts when unit is operating d Capacitor weak open or shorted d Check capacitor If defective replace Low suction cool compressor a a Iced evaporator coil a Defective overlo...

Страница 21: ...A B PCH32441 66 34 27 30 Small PCH33041 66 34 27 30 Small PCH33641 66 34 27 30 Small PCH34241 66 34 32 35 Medium PCH34841 66 34 32 35 Medium PCH36041 66 34 32 35 Medium Model Duct Openings Supply Ret...

Страница 22: ...A B PHH32441 66 34 27 30 Small PHH33041 66 34 27 30 Small PHH33641 66 34 32 35 Medium PHH34241 66 34 32 35 Medium PHH34841 66 34 32 35 Medium PHH36041 66 34 36 38 Large Model Duct Openings Supply Ret...

Страница 23: ...minum Indoor Coil Cleaning Qualified Servicer Only This unit is equipped with an aluminum tube evaporator coil The safest way to clean the evaporator coil is to simply flush the coil with water This c...

Страница 24: ...Type NG Natural Gas LP Liquid Propane Residential Package Outdoor Section ELECTRICAL Supply Voltage Measure L1 and L2 Voltage L1 L2 Compressor Amps Condenser Fan Amps PRESSURES TEMPERATURES Suction Ci...

Страница 25: ...25 THIS PAGE IS LEFT INTENTIONALLY BLANK...

Страница 26: ...26 THIS PAGE IS LEFT INTENTIONALLY BLANK...

Страница 27: ...27 THIS PAGE IS LEFT INTENTIONALLY BLANK...

Страница 28: ...o the feedback page GOODMAN BRAND AMANA BRAND GOODMAN BRAND AMANA BRAND PRODUCT REGISTRATION Thank you for your recent purchase Though not required to get the protection of the standard warranty regis...

Отзывы: