SCHEDULED MAINTENANCE
31
Coil Cover
Coil Cover
ID Blower
ID Blower
Set Point on
Max Make
Set Point on
Max Make
Pressure Fall
On Pressure Pressure Fall
On Pressure
(PF) W.C.
Rise W.C.
(PF) W.C.
Rise W.C.
*M9S960403ANAA
- 0.10 ± .05
- 0.25
- 0.35 ± .05
- 0.50
0130F00642
*M9S960603BNAA
- 0.10 ± .05
- 0.25
- 1.49 ± .07
- 1.70
0130F00478
*M9S960803BNAA
- 0.10 ± .05
- 0.25
- 1.27 ± .07
- 1.48
0130F00477
*M9S960804CNAA
- 0.10 ± .05
- 0.25
- 1.27 ± .07
- 1.48
0130F00477
*M9S960805CNAA
- 0.10 ± .05
- 0.25
- 1.27 ± .07
-1.48
0130F00477
*M9S961004CNAA
- 0.10 ± .05
- 0.25
- 1.27 ± .07
- 1.48
0130F00477
*M9S961205DNAA
- 0.10 ± .05
- 0.25
- 0.85 ± .05
- 1.00
0130F00476
*C9S960403BNAA
- 0.08 ± .04
- 0.16
- 1.49 ± .07
- 1.70
0130F00484
*C9S960603BNAA
- 0.10 ± .05
- 0.25
- 1.49 ± .07
- 1.70
0130F00477
*C9S960804CNAA
- 0.10 ± .05
- 0.25
- 1.49 ± .07
- 1.70
0130F00477
*C9S961005CNAA
- 0.10 ± .05
- 0.25
- 1.49 ± .07
- 1.70
0130F00477
*C9S961205CNAA
- 0.10 ± .05
- 0.25
- 0.85 ± .05
- 1.00
0130F00476
*M9S96 / *C9S96 Pressure Switch Trip Points And Usage Chart
Model
ID Blower
Coil Cover
Pressure
Switch
Assembly
Part #
Model
Coil Cover
Set Point on
Pressure Fall
(PF) W.C.
Coil Cover
Max Make
On Pressure
Rise W.C.
ID Blower
Set Point on
Pressure Fall
(PF) W.C.
ID Blower
Max Make
On Pressure
Rise W.C.
ID Blower
Coil Cover
Pressure Switch
Assembly Part #
*M9S920403ANAA
- 0.10 ± .05
-0.25
- 0.20 ± .05
-.035
0130F00641
*M9S920603BNAA
- 0.10 ± .05
-0.25
- 1.20 ± .05
-1.41
0130F00480
*M9S920803BNAA
- 0.10 ± .05
-0.25
- 0.97 ± .05
-1.12
0130F00479
*M9S920804CNAA
- 0.10 ± .05
-0.25
- 1.20 ± .05
-1.41
0130F00480
*M9S920805CNAA
- 0.10 ± .05
-0.25
- 1.20 ± .05
-1.20
0130F00480
*M9S921004CNAA
- 0.10 ± .05
-0.25
- 0.97 ± .05
-1.12
0130F00479
*M9S921005CNAA
- 0.10 ± .05
-0.25
- 0.97 ± .05
-1.12
0130F00479
*M9S921205DNAA
- 0.10 ± .05
-0.25
- 1.20 ± .05
-1.41
0130F00480
*M9S92 Pressure Switch Trip Points And Usage Chart