Installation Instructions
16021879 Rev. 0
©
2002 Maytag Appliances Company
8
Example Four
1. Remove cap with screwdriver slot.
2. Reverse and replace cap. Verify “LPG10” is visible.
3. Do not disturb spring beneath cap.
Natural Gas
L.P. Gas
Cap
Spring
Example Five
1. Remove cap with screwdriver slot.
2. Remove black insert marked “NAT.” from cap. Insert
fits tightly in cap.
3. Reverse insert.
4. Replace in hole. Verify “LP” is visible. Verify that
insert is pressed firmly into shoulder. Do not disturb
spring in regulator body.
5. Replace cap in regulator body and tighten.
Natural Gas
L.P. Gas
Cap
Insert
Spring
Example Six
1. Remove cap with screwdriver slot.
2. Remove spring and washer. Washer will be at bottom
of spring as illustrated below.
3. Reverse to bring washer to the top.
4. Reinstall spring and washer.
5. Tighten cap.
Cap
Washer
Natural Gas
L.P. Gas
Converting Burners to LP Gas All Models
Universal units have double coaxial orifices sized for
natural gas. Converting these orifices requires tightening
the orifice hood as described below.
1. Remove grates, burner caps, knobs and control
panel.
2. Remove or lift up maintop.
3. Remove venturi assemblies. Orifice hoods become
accessible.
4. Turn clockwise each orifice hood approximately 1-1/2
to 2 turns. Orifices should fit snugly on the pins. Do
not damage or distort the hole through pin center by
overtightening.
Pin
Orifice Hood
L.P. Gas
Natural Gas
Universal
Burner Orifice
Universal
Burner Orifice
L.P. Gas
Natural Gas
5. Replace venturi assemblies, maintop, controls panel,
knobs, burner caps and grates.
CAUTION
!
Do not overtighten orifice hood. Damage to pins inside
the orifice hoods may result if hoods are overtightened.