Maytag AKO2000 Скачать руководство пользователя страница 5

Introduction

©

2002 Maytag Appliances Company

16021879 Rev. 0

5

Modern Maid Cooking Products Nomenclature

Product Group

Product Type

Series

Features

Fuel

Color

D-Dishwasher
F-Electric Product
G-Refrigerator
K-Cooktop
M-Microwave Oven
P-Gas Product
X-Kit or Accessory

BR-Backguard Kit
DC-Electric

Single/Double
Convection Wall
Oven, Self-Clean

DO-Electric

Combination Wall
Oven, Self-Clean

DU-Electric Slide-In

Wall oven, Self-
Clean

ET-Electric Cooktop

(Coil or
Downdraft)

GO-Gas Wall Oven,

Manual Clean

GT-Gas Cooktop
HO-Double Gas Wall

Oven, Self-Clean

HU-Gas Slide-In Wall

Oven, Self-Clean

KO-Gas Wall Oven,

Continuous
Clean

Variable

Variable

N-Natural

Gas Only

U-Universal

(Set for
natural
gas)

1-120 Volts,

60 Hz.

2-240 Volts,

60Hz.

W-White
WW-White on White
WW1-White on

White/1 pc.
grate

B-Black
B1-Black/1 pc. grate
L-Almond
K-Chrome Top
D-Black Glass

Caloric Cooking Products Nomenclature

Product Group

Product Type

Series

Features

Fuel

Color

E-Electric Product
R-Gas Range
T-Trash Compactor
H-Vent Hood
M-Microwave Oven
D-Dishwasher

C-Convertible
H-High Broil
J-Hi-Broil w/Cont.

Cleaning Panels

K-Upper Oven

Microwave Lower
- Self-Cleaning

L-Low Broil
M-Low Broil w/Cont.

Cleaning Panels

P-Portable

R-Microwave/Electric
S-Self-Clean
T-Cooktop
U-Undercounter
V-Variable Power
W-Wall Oven w/Cont.

Cleaning Panels

Y-Self-Cleaning

P
R
D
S

Variable

N-Natural

Gas

L-Bottled Gas
U-Universal
1-115 Volts
2-240 Volts
8-208 Volts

0-No Color
1-White
2-Antique Copper
3-Avocado
4-Autumn
5-Satin/Stainless
Steel
6-Black
8-Color Pack
9-Color Pack
H-Harvest
L-Almond
W-White

Gas Cooktop Feature Chart

Model

Burner Ignition

Thermoset

Burner

Tri-Set

Controls

Hinged Top

Overall

Dimensions

Width

Depth

AKO2000

Spark

AKS30

Spark

29-1/2”

21”

AKS3020

Spark

29-1/2”

21-1/2”

AKS3030

Spark

29-1/2”

21-1/2”

AKS3040

Spark

29-1/2”

21-1/2”

AKS3050

Spark

29-1/2”

21-1/2”

CKS3020

Spark

29-1/2”

21-1/2”

GT341

Spark

GT451

Spark

GT583

Spark

PGT120

Spark

PGT153

Spark

29-1/2”

21”

KGT341

Spark

RTP201

Pilot

23-1/2”

19-3/4”

RTP203

Pilot

23-1/2”

19-3/4”

RTP300

Pilot

29-1/2”

21”

RTP302

Pilot

X

X

29-1/2”

21”

RTP304

Pilot

X

X

29-1/2”

21”

RTP305

Pilot

X

X

X

29-1/2”

21”

RTP306

Spark

X

X

29-1/2”

21”

RTP307

Spark

X

X

X

29-1/2”

21”

RTP308

Spark

29-1/2”

21”

Refer to Rating Label on above models for information on Natural/L.P. gas supply pressure.

Содержание AKO2000

Страница 1: ...AKS3040 PAKS3040 AKS3050 P1142526N CKS3020 P1142515N GT341 GT451 GT583 KGT341 P1123230N KGT341 P1131428N PGT120U P1142504N PGT153U P1142506N RTP201 P1131401N RTP203 RTP300 RTP302 RTP304 RTP305 RTP306...

Страница 2: ...not be responsible for any injury or property damage arising from improper service or service procedures If you perform service on your own product you assume responsibility for any personal injury or...

Страница 3: ...Cutout 12 Clearances 12 Above a Drawer 12 Placing Unit in Countertop 12 Adjusting Top Pilots Gas Ignition 12 Automatic Pilotless Ignition Models 12 Installation Notes AKS3020 AKS3030 AKS3040 AKS3050 a...

Страница 4: ...ipments and delays Please refer to parts catalog when ordering replacement parts New Old Amana Cooking Products Nomenclature Brand Product Fuel Type Configuration Width Feature Series Color A Amana C...

Страница 5: ...ertible H High Broil J Hi Broil w Cont Cleaning Panels K Upper Oven Microwave Lower Self Cleaning L Low Broil M Low Broil w Cont Cleaning Panels P Portable R Microwave Electric S Self Clean T Cooktop...

Страница 6: ...Cooktop power cords are equipped with a three prong grounded plug They fit standard three prong wall receptacles WARNING To avoid risk of serious electrical shock or property damage Do not cut or remo...

Страница 7: ...difying the gas supply pressure regulator and individual burner valves enables these units to use LP gas Pressure Regulator Conversion All Models Amana uses several types of gas pressure regulators fo...

Страница 8: ...verse to bring washer to the top 4 Reinstall spring and washer 5 Tighten cap Cap Washer Natural Gas L P Gas Converting Burners to LP Gas All Models Universal units have double coaxial orifices sized f...

Страница 9: ...nd locating adjustment screws for models with pilot lights are covered in installation notes for those models A properly adjusted pilot flame means the burner will correctly ignite Problems caused by...

Страница 10: ...he underside of cooktop Pull each tab outward to form a 90 degree angle with bottom of cooktop Tabs keep cooktop from being lifted out of cooktop Removal and Replacement of the Cooktop 1 Shut off elec...

Страница 11: ...sure regulator and make adjusting the regulator easier Placing Unit in Countertop Unpack all parts Access the burner compartment by removing the maintop as follows 1 Remove top grates burner bowls and...

Страница 12: ...supply box It is important that the wall receptacle be located within the cabinet cutout specifications Placing Unit in Countertop Remove all literature packed with cooktop To access the burner compar...

Страница 13: ...gulator and make adjusting the regulator easier Placing Unit in Countertop Remove all literature packed with cooktop 1 Remove burner grates and caps 2 Remove screws securing burners to cooktop 3 Unplu...

Страница 14: ...ing and roasting Cast iron responds slowly to temperature changes It responds best for long low heat cooking and pan frying Stainless steel combined with another metal such as copper responds better t...

Страница 15: ...When burner lights turn control to desired setting 3 When finished cooking turn all controls to OFF Cleaning Do not clean cooktop until it cools Sudden temperature changes can crack the porcelain or...

Страница 16: ...g Sealed Burners Open Head Burners Open head burners can be removed for cleaning Maintop and burners must be cool before cleaning 1 Remove grates Lift or remove maintop 2 Grasp burners at burner head...

Страница 17: ...r ignition ports Adjust air shutters according to installation instructions Adjust burner flame according to LP conversion information in installation instructions 3 Burners will not ignite No Spark a...

Страница 18: ...er lead on the opposite end of the ignitor lead that is attached to the top burner mounting bracket Repeat same procedure with the other ignitor lead No continuity on either lead indicates an open cir...

Страница 19: ...t Fittings Applicable Models 1 Remove maintop 2 Turn pilot gas off at pilot adjusting screw 3 Remove tubing nut at pilot assembly 4 Remove pilot shield on channel and cone in pilot cup 5 Pilot assembl...

Страница 20: ...See Diecast Burners section 3 Remove maintop See Maintop section 4 Remove screws securing spark module to burner box 5 Disconnect lead wires to spark module and remove 6 Reverse procedure to reinstall...

Страница 21: ...1 2 N L1 Spark Module Voltage Wire Electrode RD SF2 Spark Switches RD SF2 RD SF2 RD SF2 1 2 3 1 2 3 WH SF2 GN SF2 Power Cord Main Input Ribbed or Striped Side of Cord 3 SKT Cap 3 Pin Plug WIRING DIAGR...

Страница 22: ...or AKS30 PGT153 and RTP308 NOTE 1 All wires 18GA 150 C XL unless otherwise specified 2 All replacement wires must have same ratings as original wires Neutral L N Spark Module High Voltage Output 1 2 3...

Страница 23: ...ersonal injury or death disconnect power to cooktop before servicing unless testing requires it Supply Cord G Disconnect Switches Spark Module Electrode G R R R W Switches Ignitor L1 N SCHEMATIC WIRIN...

Страница 24: ...ry or death disconnect power to cooktop before servicing unless testing requires it Supply Cord G Disconnect Switches Spark Module Electrodes W Switches Module L1 N SCHEMATIC WIRING DIAGRAM Part Numbe...

Страница 25: ...ath disconnect power to cooktop before servicing unless testing requires it Valve Switches Spark Module 9 8 7 6 SCHEMATIC L N Valve Switches Spark Module 1 2 3 1 2 3 L N BL W BL BL L N 9 8 7 6 Disconn...

Страница 26: ...th disconnect power to cooktop before servicing unless testing requires it 120 VAC W B Spark Module N 1 2 L Spark Ignitors Front Rear Micro Switches Thermoset R W COM COM NO NO B NOTE Replacement wire...

Страница 27: ...nless testing requires it Electric Ignitor Circuit for AKS3020 AKS3030 AKS3040 AKS3050 and CKS3020 Part Number 35 317134 05 0 Manifold Switches Line Neutral Spark Module L N A B A1 B1 1 2 3 4 or Surfa...

Отзывы: