background image

5

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions
can result in death or fire.

WARNING

Exhaust requirements

An exhaust hood should cap the
exhaust vent to prevent exhausted air
from returning to the dryer.

Exhaust outlet hood
must be at least 30.5
cm (12 inches) from
the ground or any
object that may be in
the path of the
exhaust (such as
flowers, rocks or bushes, etc.).

If using an existing exhaust system
clean lint from entire length of system
and make sure exhaust hood is not
plugged with lint. Replace any vinyl or
metallised plastic foil vent with rigid
metal or flexible metal vent.

Use 100 mm (4") clamps to seal all
joints. Do Not use screws to secure
vent.

Service check: Back pressure in any
exhaust system used must not exceed
15.2 mm (0.6 inches) in water column
measured with an incline manometer
at the point that exhaust vent connects
to dryer.

• Do Not use non-metal flexible vent,

metal vent that is smaller than 
100 mm (4") in diameter or exhaust
hoods with magnetic latches.

• Do Not exhaust dryer into a chimney,

furnace, cold air vent, attic or crawl
space, or any other vent used for
venting.

• Do Not install flexible vent in

enclosed walls, ceilings or floors.

Important: Observe all governing
codes and ordinances.

Exhaust your dryer to the outside.
Moisture and lint indoors may cause:

• Lint to gather around the dryer where

it can be fuel for a fire.

• Moisture damage to woodwork,

furniture, paint, wallpaper, carpet etc.

• Housecleaning problems and health

problems.

10 cm (four-inch) diameter vent is
required for best performance.

Rigid or flexible metal exhaust vent
must be used. 
Do Not use plastic or
foil-covered vent.

Rigid metal vent is recommended to
prevent crushing and kinking.

Flexible metal vent must be fully
extended and supported when the
dryer is in its final position. Remove
excess flexible vent to avoid sagging
and kinking that may result in reduced
air flow.

30.5 cm
(12") min.

Plan the exhaust vent
installation

Route the vent

The exhaust outlet is located at the
centre of the rear of the dryer.

The exhaust vent can be routed up,
down, left, right or straight out the back
of the dryer.

The design of the flue system should
ensure that any condensate formed
when operating the appliance from cold,
is either retained and subsequently
evaporated or discharged. Following
these installation instructions should
adequately meet this requirement.

Select the route that will provide the
straightest and most direct path
outdoors. 
Plan the installation to use
the fewest number of elbows and turns.
Avoid making 90° turns.

better 

exhaust air flow

good

When using elbows or making
turns, 
allow as much room as
possible. Bend vent gradually to avoid
kinking.

Содержание 3RLGR5437

Страница 1: ...djustment of the appliance are compatible If in doubt then installer must contact the gas supplier This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space Consult instructions before installation and use of this appliance Installation service or conversion for use on other gas supplies must be done by a competent installer service age...

Страница 2: ...mbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean level gloves 20 or 30 cm 8 or l0 adjustable wrench that opens to 2 5 cm 1 flat blade screwdriver safety glasses 1 4 nut driver or socket wrench caulking gun and compound knife duct tape 20 or 30 cm 8 or l0 pipe wren...

Страница 3: ...rying operation The operation of this appliance may affect the operation of other gas appliances which take their air supply for safe combustion from the same room If in doubt consult the appliance manufacturers Exhaust to outdoors Dryer must be exhausted outdoors to prevent exposure to harmful substances in the gas fuels to prevent large amounts of lint and moisture from accumulating and to maint...

Страница 4: ...e of gas available see your dealer Natural Gas This dryer is factory adjusted for use with NATURAL GAS G20 and no further adjustment should be required at installation L P Gas This dryer is also certified for use with L P propane or butane gases with appropriate conversion No attempt shall be made to convert the appliance from the gas specified on the model serial rating plate for use with a diffe...

Страница 5: ...overning codes and ordinances Exhaust your dryer to the outside Moisture and lint indoors may cause Lint to gather around the dryer where it can be fuel for a fire Moisture damage to woodwork furniture paint wallpaper carpet etc Housecleaning problems and health problems 10 cm four inch diameter vent is required for best performance Rigid or flexible metal exhaust vent must be used Do Not use plas...

Страница 6: ...w installation 1 Put on safety glasses and gloves 2 Install exhaust hood Use caulking compound to seal exterior wall opening around exhaust hood 3 Connect exhaust vent to hood with 100 mm 4 clamp Exhaust vent MUST fit inside hood 4 Run exhaust vent to dryer location Use the straightest path possible Avoid 90 turns Use 100 mm 4 clamps to secure vent pieces Tin snips may be needed to cut vent to req...

Страница 7: ... 100 mm 4 clamps have all the tools you started with 2 Plug electricity supply cord into an earthed socket outlet Turn power supply on 3 Read the Use and Care Guide to fully understand your new dryer Select a full heat cycle not the air cycle and start dryer After five minutes open dryer door You should feel heat inside dryer or on the exhaust duct If the burner did not ignite and you do not feel ...

Страница 8: ...r 30 mbar Adjusted pressure N A N A NOTE Conversion kit From Natural Gas to LP Gas Whirlpool Part No 279918 Manufacturer Whirlpool Corporation Benton Harbor Michigan 49022 USA Moving dryer to a new location Check with your gas supplier or dealer to confirm that your dryer is equipped with the correct burner for the particular type of gas in your new location Burner information is specified on the ...