Power Test 

All Amana and Menumaster microwave oven power outputs are rated using the IEC705 standards. Using the IEC705 
test method requires precision measurements and equipment that is not practical to be performed in the field. Using 
the test shown below will indicate if the oven performance is satisfactory. 

 

Test equipment required: 

 

1000 ml test container and thermometer (Amana power test kit R0157397 Fahrenheit / Menumaster power 
test kit M95D5 Celsius).  

 

Digital watch / watch with a second hand for use on ovens with electromechanical timers. 

Important Notes: 

 

Low line voltage will cause low temperature rise / power output. 

 

Ovens must be on a dedicated circuit, properly grounded, and polarized. Other equipment on the same 
circuit may cause a low temperature rise / power output. 

 

This test and results are not a true IEC705 test procedure and are only intended to provide servicers with an 
easy means of determining if the microwave oven cooking output is correct. 

Procedure 

1.  Fill the test container to the 1000 ml line with cool tap water. 

NOTE:

 

Water temperature should be approximately 60

°

F / 16

°

2.  Using the thermometer, stir water for five to ten seconds; measure, and record the temperature (T1). 
3.  Place test container of water in the center of oven cavity and close door. 
4.  Heat the water for a 33-second full power cycle. 

NOTE:

 

Use a digital watch or a watch with a second hand for ovens with electromechanical timers. 

1.  At end of the cycle, remove test container. Using the thermometer, stir water for five to ten seconds and record 

temperature (T2). 

2.  Subtract the starting water temperature (T1), from the ending water temperature (T2) to obtain the temperature 

rise (

T). 

3.  If the temperature rise (

T) meets or exceeds the minimum, the test is complete. If the temperature rise (

T) 

fails to meet the minimum temperature rise, test the line voltage to verify it is correct. Then repeat steps 1-6 
making sure to change the water. If the temperature rise (

T) fails to meet the minimum temperature rise again 

the oven will require service. 

Minimum Temperature Rise at Thirty -Three (33) Seconds Run Time 

T Cooking 

T Cooking 

T Cooking 

T Cooking 

(°F) 

Power Output 

(°F) 

Power Output  

(°C) 

Power Output 

(°C) 

Power Output 

10 ................. 1000 20................. 2000 

.............. 1000 11............ 2000 

11 ................. 1100 21................. 2100 

5.5 ............ 1100 11.5......... 2100 

12 ................. 1200 22................. 2200 

6.5 ............ 1200 12............ 2200 

14 ................. 1400 24................. 2400 

7.5 ............ 1400 13............ 2400 

17 ................. 1700 25................. 2500 

9.5 ............ 1700 13.5......... 2500 

18 ................. 1800 27................. 2700 

10 ............. 1800 15............ 2700 

19 ................. 1900 30................. 3000 

10.5 .......... 1900 16.5......... 3000 

 
 

Содержание ACE5302

Страница 1: ...icing unless testing requires power Models ACE5302 DS30E2 UACE5302 UDS30E2 UCA2000NT2 Power Source Voltage AC 230 VAC 230 VAC Amperage Single Unit 16 A 13 A Frequency 50 Hz 50 Hz Single Phase 3 wire grounded X X Plug CEE 7 7 Schuko BS1363A Power Output Microwave Nominal microwave energy IEC705 1000 Watts 1000 Watts Traditional test method 900 Watts 900 Watts Minimum temperature rise T 18ºF 10ºC 18...

Страница 2: ...re to terminal MT2 removed Infinite Approximately 15 Ω then reverse meter leads 30 Ω Infinite Infinite Triac 1 top is for front element Triac 2 middle is for rear element Triac 3 bottom is for microwave Measure voltage from MT1 to Gate 0 8 VAC when energized If no voltage check H V board and wiring Capacitor Discharge Capacitor Remove wires from capacitor terminals and connect ohmmeter set on high...

Страница 3: ...minal 4 to 5 Terminal 7 to 8 With door closed measure resistance from Terminal 2 to 3 Terminal 4 to 5 Terminal 7 to 8 Infinite Infinite Indicates continuity Indicates continuity Indicates continuity Infinite A B Convection blower motor Remove wires from motor Measure resistance across terminals A and B Approximately 20 Ω Heating element assembly Disconnect wires from terminals Measure resistance a...

Страница 4: ...ty Continuity Continuity Top touch panel Continuity is indicated as 100 Ω and below 1 Pad Preheat Time Entry Temp Entry Power Level Stage Program Save Hidden Pad Trace 3 4 5 7 7 8 5 8 5 9 6 7 8 9 Measurement Continuity Continuity Continuity Continuity Continuity Continuity Continuity Wire harness High voltage board to display module harness Test continuity of wires Indicates continuity Display boa...

Страница 5: ...ack wire J1 pin 2 Red wire Line voltage Output to display board Disconnect J5 connector Volts J5 pin 28 J5 pin 50 24 VDC Relay Function Test Set Up Meter Setting Probe Placement Results K1 Cooling fan Disconnect J2 connector Ohms J1 pin 1 Black wire J2 pin 4 Test mode 5 off no continuity Test mode 5 on 1 Ω K2 Convection motor Disconnect J2 connector Ohms J1 pin 1 Black wire J2 pin 3 Test mode 4 of...

Страница 6: ... container to the 1000 ml line with cool tap water NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with...

Страница 7: ...imer counts up to 99 seconds Timer counts up to 99 seconds Timer counts up to 62 seconds and unit shuts off STG COOK PREHEAT STANDBY ITEM POWER C M 1 2 3 4 QTY LEVEL NOT READY LMT Component Evaluation STG COOK PREHEAT STANDBY ITEM POWER C M 1 2 3 4 QTY LEVEL NOT READY LMT 0 Deactivated 1 Activated Displays actual Amperage Displays actual Amperage Indicates Service Mode If no Amperage check Heating...

Страница 8: ...QTY LEVEL NOT READY LMT LMT LMT LMT 6 7 8 9 0 Toggles Oven Light ON OFF Displays of Magnetron Hours Displays of Door Cycles with a 1 to 1 ratio rounded to the nearest ten Clears Hours and Cycles press START to activate Resets to 0 Displays current Temperature OFFSET TEMP Display current oven Temperature as sensed by RTD Press Display Component Evaluation STG COOK PREHEAT STANDBY ITEM POWER C M 1 2...

Страница 9: ... C Cycle 2 230 C 240 C 450 C 480 C 930 C 930 C 4 230 C average temperature If the average temperature is too high or too low the oven temperature offset needs to be calibrated Convection Temperature Calibration NOTE It is normal for the average oven temperature to vary from the oven setting by as much as 25 F 14 C Difference will not effect cooking since recipes are written with this difference in...

Страница 10: ...odes During operation the display may show the following service codes NOTE Before scheduling service for any error codes instruct customer to unplug oven for 1 minute reconnect power and retest If unit operates properly no service call is required Display Description Corrective Action Err1 Failed H V Board See note above Replace H V board Err2 Failed Touch Panel Failed H V Board Replace Touch pan...

Страница 11: ...G To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power March 2005 16025975 2005 Maytag Services 11 12747601 UACE5302 UDS30E2 UCA2000NT2 ...

Страница 12: ... risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power 16025975 March 2005 2005 Maytag Services 12 12747601 DANGER HIGH VOLTAGE UACE5302 UDS30E2 UCA2000NT2 ...

Страница 13: ...W ARNING To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power March 2005 16025975 2005 Maytag Services 13 12747701 ACE5302 DS30E2 ...

Страница 14: ...o avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power 16025975 March 2005 2005 Maytag Services 14 12747701 DANGER HIGH VOLTAGE ACE5302 DS30E2 ...

Отзывы: