Maytag Services ACE5302 Скачать руководство пользователя страница 10

Display Diagnostics 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor  
before servicing, unless testing requires power. 

 

16025975  

March 

2005 

©2005 Maytag Services

 

10

 

CAUTION

!

 

All repairs as described in this troubleshooting section are to be performed only after the caution procedures one through 
eight listed below have been followed. 
1.  Check grounding before checking for possible causes. 
2.  Be careful of the high voltage circuit. 
3.  Discharge high voltage capacitor. 
4.  When checking the continuity of the switches or the high voltage transformer, disconnect one lead wire from these parts 

and then check continuity with the AC plug removed.  To do otherwise may result in a false reading or damage to your 
meter. 

5.  Do not touch any parts of the circuitry on the P.C. Board circuit since static electric discharge may damage this control 

panel. Always touch yourself to ground while working on this panel to discharge any static charge in your body. 

6.  208/230 VAC is present in the high voltage circuit board, power relay and primary circuit of low voltage transformer. 
7.  When troubleshooting, be cautious of possible electrical hazard. 
8.  When testing convection operation, convection fan may start at any time or if oven is hot. 

Error Codes 

During operation, the display may show the following service codes: 

NOTE: 

Before scheduling service for any error codes, instruct customer to unplug oven for 1 minute, reconnect 
power, and retest. If unit operates properly, no service call is required. 

Display Description 

Corrective 

Action 

Err1 

Failed H.V. Board 

See note above. 
Replace H.V. board. 

Err2 

Failed Touch Panel 
Failed H.V. Board 

Replace Touch panel. 
See note above. 
Replace H.V. board. 
May be a failed Touch Panel. Verify before replacing H.V. Board. 

Err3 

Failed H.V. Board 
Failed Touch Panel 

See note above. 
Replace H.V. board. 
Replace Touch panel. 
May be a failed Touch Panel. Verify before replacing. 

Err4 

Failed H.V. Board 

See note above. 
Replace H.V. board. 

Err5 

Failed Touch Panel 

See note above. 
If Touch Panel is pressed for more than 30 seconds, this error code will 
appear. 
Replace touch panel. 

Err6 

Failed H.V. Board 

See note above. 
Replace H.V. board. 

Err7 

Error with RTD circuit 
If power level shows 

0-Uncalibrated .................................................  
1-Shorted RTD circuit ......................................  
2-Open RTD circuit..........................................  

See note above. 
 

Replace H.V. board. 
Check RTD and wiring to H.V. board. 
Check RTD and wiring to H.V. board. 

HOT 

 

See note above. 
Open TCO. 
Convection motor inoperative. 
Restricted air filter. 
H.V. board inoperative. 
Broken or loose wire. 

Door 

Door Interlock Primary Switch 

See note above. 
Verify latch mechanism moves freely on door. 
Verify J1 connector on display board is properly seated. 
Test interlock switch assembly and perform door adjustment if necessary.
Replace interlock switch assembly if failed. 

 

Содержание ACE5302

Страница 1: ...icing unless testing requires power Models ACE5302 DS30E2 UACE5302 UDS30E2 UCA2000NT2 Power Source Voltage AC 230 VAC 230 VAC Amperage Single Unit 16 A 13 A Frequency 50 Hz 50 Hz Single Phase 3 wire grounded X X Plug CEE 7 7 Schuko BS1363A Power Output Microwave Nominal microwave energy IEC705 1000 Watts 1000 Watts Traditional test method 900 Watts 900 Watts Minimum temperature rise T 18ºF 10ºC 18...

Страница 2: ...re to terminal MT2 removed Infinite Approximately 15 Ω then reverse meter leads 30 Ω Infinite Infinite Triac 1 top is for front element Triac 2 middle is for rear element Triac 3 bottom is for microwave Measure voltage from MT1 to Gate 0 8 VAC when energized If no voltage check H V board and wiring Capacitor Discharge Capacitor Remove wires from capacitor terminals and connect ohmmeter set on high...

Страница 3: ...minal 4 to 5 Terminal 7 to 8 With door closed measure resistance from Terminal 2 to 3 Terminal 4 to 5 Terminal 7 to 8 Infinite Infinite Indicates continuity Indicates continuity Indicates continuity Infinite A B Convection blower motor Remove wires from motor Measure resistance across terminals A and B Approximately 20 Ω Heating element assembly Disconnect wires from terminals Measure resistance a...

Страница 4: ...ty Continuity Continuity Top touch panel Continuity is indicated as 100 Ω and below 1 Pad Preheat Time Entry Temp Entry Power Level Stage Program Save Hidden Pad Trace 3 4 5 7 7 8 5 8 5 9 6 7 8 9 Measurement Continuity Continuity Continuity Continuity Continuity Continuity Continuity Wire harness High voltage board to display module harness Test continuity of wires Indicates continuity Display boa...

Страница 5: ...ack wire J1 pin 2 Red wire Line voltage Output to display board Disconnect J5 connector Volts J5 pin 28 J5 pin 50 24 VDC Relay Function Test Set Up Meter Setting Probe Placement Results K1 Cooling fan Disconnect J2 connector Ohms J1 pin 1 Black wire J2 pin 4 Test mode 5 off no continuity Test mode 5 on 1 Ω K2 Convection motor Disconnect J2 connector Ohms J1 pin 1 Black wire J2 pin 3 Test mode 4 of...

Страница 6: ... container to the 1000 ml line with cool tap water NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with...

Страница 7: ...imer counts up to 99 seconds Timer counts up to 99 seconds Timer counts up to 62 seconds and unit shuts off STG COOK PREHEAT STANDBY ITEM POWER C M 1 2 3 4 QTY LEVEL NOT READY LMT Component Evaluation STG COOK PREHEAT STANDBY ITEM POWER C M 1 2 3 4 QTY LEVEL NOT READY LMT 0 Deactivated 1 Activated Displays actual Amperage Displays actual Amperage Indicates Service Mode If no Amperage check Heating...

Страница 8: ...QTY LEVEL NOT READY LMT LMT LMT LMT 6 7 8 9 0 Toggles Oven Light ON OFF Displays of Magnetron Hours Displays of Door Cycles with a 1 to 1 ratio rounded to the nearest ten Clears Hours and Cycles press START to activate Resets to 0 Displays current Temperature OFFSET TEMP Display current oven Temperature as sensed by RTD Press Display Component Evaluation STG COOK PREHEAT STANDBY ITEM POWER C M 1 2...

Страница 9: ... C Cycle 2 230 C 240 C 450 C 480 C 930 C 930 C 4 230 C average temperature If the average temperature is too high or too low the oven temperature offset needs to be calibrated Convection Temperature Calibration NOTE It is normal for the average oven temperature to vary from the oven setting by as much as 25 F 14 C Difference will not effect cooking since recipes are written with this difference in...

Страница 10: ...odes During operation the display may show the following service codes NOTE Before scheduling service for any error codes instruct customer to unplug oven for 1 minute reconnect power and retest If unit operates properly no service call is required Display Description Corrective Action Err1 Failed H V Board See note above Replace H V board Err2 Failed Touch Panel Failed H V Board Replace Touch pan...

Страница 11: ...G To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power March 2005 16025975 2005 Maytag Services 11 12747601 UACE5302 UDS30E2 UCA2000NT2 ...

Страница 12: ... risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power 16025975 March 2005 2005 Maytag Services 12 12747601 DANGER HIGH VOLTAGE UACE5302 UDS30E2 UCA2000NT2 ...

Страница 13: ...W ARNING To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power March 2005 16025975 2005 Maytag Services 13 12747701 ACE5302 DS30E2 ...

Страница 14: ...o avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power 16025975 March 2005 2005 Maytag Services 14 12747701 DANGER HIGH VOLTAGE ACE5302 DS30E2 ...

Отзывы: