29
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
Country:
DE, LU, PL
European Gas Category:
I
2E
Gas Flow Rate:
0.562703 m
3
/hr
Supply Pressure (G20):
20 mbar
Factory Adjusted Pressure (G20):
7.4 mbar
Factory set for Australia/New Zealand NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
Country:
AU, NZ
Supply Pressure (G20):
minimum 1.13 kPa
Adjusted Pressure (Test Point Pressure):
0.74 kPa
Nominal Hourly Gas Consumption:
21.1 MJ/h
With Australia L.P. Gas Conversion Kit: Injector Size: 1.40 mm Heat input gross: 6.54 kW
Country:
AU, NZ
L.P. Supply Pressure:
2.75 kPa
Adjusted Pressure:
2.75 kPa
Nominal Hourly Gas Consumption:
23 MJ/h
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.0 kW
Country:
NL
European Gas Category:
I
2L
II
2L3B/P
Gas Flow Rate:
0.562703 m
3
/hr
0.562703 m
3
/hr
Supply Pressure (G25):
25 mbar
25 mbar
Factory Adjusted Pressure (G25) :
7.4 mbar
7.4 mbar
Supply Pressure (G30/G31):
Not Applicable
30 mbar
Factory Adjusted Pressure (G30/G31):
Not Applicable
Not Applicable
NOTE: Conversion kit: From Natural Gas to L.P. Gas - Europe: Whirlpool Part No. W10571757.
Conversion kit: From Natural Gas to L.P. Gas - Australia: Whirlpool Part No. W10571729.
Conversion kit: From Natural Gas to Natural Gas - France/Belgium: Whirlpool Part No. W10181947.
Manufacturer: Whirlpool Corporation, Benton Harbor, Michigan 49022, U.S.A.
Manufacturing Site: Whirlpool Corporation, 1300 Marion-Agosta Rd., Marion, OH, 43302, U.S.A.
EU Representatives: Whirlpool EMEA S.p.A., Via Carlo Pisacane, 1, 20016 Pero (MI) Italy
TECHNICAL SPECIFICATIONS – GAS DRYER