background image

17

1. 

Place towel on dryer

Place towel on top of dryer to avoid damaging the surface.

Lift door until top screws in dryer cabinet are in large part of 

hinge slot. Pull door forward off screws. Set door (handle side 

up) on top of dryer. Remove top screws from dryer cabinet.

3. 

Lift door off top screws

2. 

Remove bottom screws

Open dryer door. Remove bottom screws from dryer cabinet 

side of hinges. Loosen (do not remove) top screws from dryer 

cabinet side of hinges.

COMPLETE INSTALLATION 

CHECKLIST

  Check that all parts are now installed. If there is an extra 

part, go back through steps to see what was skipped.

  Check that you have all of your tools.

  Dispose of/recycle all packaging materials.

  Check dryer’s fi nal location. Be sure vent is not crushed 

or kinked.

  Check that dryer is level. See “Level Dryer.”

  Remove fi lm on console and any tape remaining on dryer.

  Wipe dryer drum interior thoroughly with a damp cloth to 

remove any dust.

  Read “Dryer Use” in your Use and Care Guide.

  Set the dryer on a full heat cycle (not an air cycle) 

for 20 minutes and start the dryer.

If the dryer will not start, check the following:

 

Controls are set in a running or On position.

 

Start button has been pushed fi rmly.

 

Dryer is plugged into an outlet and/or electrical supply 

is on.

 

Household fuse is intact and tight, or circuit breaker has 

not tripped.

 

Dryer door is closed.

 

When the dryer has been running for 5 minutes, open the 

dryer door and feel for heat. If you feel heat, cancel cycle 

and close the door.

If you do not feel heat, turn off dryer, and check the 

following:

 

There may be two household fuses or circuit breakers 

for the dryer. Check that both fuses are intact and tight, 

or that both circuit breakers have not tripped. If there 

is still no heat, contact a qualifi ed technician.

NOTE:

 You may notice an odor when the dryer is fi rst heated. 

This odor is common when the heating element is fi rst used. 

The odor will go away.

REVERSE DOOR SWING 

(OPTIONAL)

NOTE: 

Magnetized screwdriver is helpful.

27" Wide Model Side-Swing Door

Содержание MEDP575G

Страница 1: ...NSTALLATION INSTRUCTIONS 27 WIDE MODELS U S A ONLY Para obtener acceso al manual de uso y cuidado en español o para obtener información adicional acerca de su producto visite www maytag com Tenga listo su número de modelo completo Puede encontrar el número de modelo y de serie dentro de la cavidad superior de la puerta Table of Contents INSTALLATION NOTES Date of purchase _________________________...

Страница 2: ...2 DRYER SAFETY ...

Страница 3: ...Phillips screwdriver Wire stripper direct wire installations Tin snips new vent installations Adjustable wrench that opens to 1 25 mm or hex head socket wrench Vent clamps 1 4 6 mm nut driver recommended Utility knife Tape measure Pliers Level Caulking gun and compound for installing new exhaust vent Putty knife Parts supplied Leveling legs 4 Parts package is located in dryer drum Check that all p...

Страница 4: ...ilding inspector Installation clearances The location must be large enough to allow the dryer door to open fully Parts needed Check local codes Check existing electrical supply and venting and read Electrical Requirements and Venting Requirements before purchasing parts Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased yo...

Страница 5: ...m Required Spacing Additional spacing recommended Recessed Area Installation Closet Installation Mobile home Additional installation requirements This dryer is suitable for mobile home installations The installation must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 28...

Страница 6: ...ecified on the serial rating plate on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Connect to an individual branch circuit Do not have a fuse in the neutral or grounding circuit Do not use an extension cord If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path...

Страница 7: ...n Requirements ELECTRICAL CONNECTION Power Supply Cord Electrical Connection Options 1 Choose electrical connection type Power supply cord 4 wire receptacle NEMA Type 14 30R Go to 4 Wire Power Supply Cord Connection section Then go to Venting Requirements 3 wire direct connection Go to 3 Wire Direct Wire Connection section Then go to Venting Requirements 4 wire direct connection Go to 4 Wire Direc...

Страница 8: ...ief screws just enough to hold the two clamp sections C together 1 Attach power supply cord strain relief Power supply cord strain relief Power supply cord 4 wire receptacle NEMA Type 14 30R Go to 4 Wire Power Supply Cord Connection on page 9 Power supply cord 3 wire receptacle NEMA Type 10 30R Go to 3 Wire Power Supply Cord Connection on page 9 If your outlet looks like this Fire Hazard Use 10 ga...

Страница 9: ...re connections 3 Wire Power Supply Cord Connection IMPORTANT Use where local codes permit connecting cabinet ground conductor to neutral wire 4 Connect remaining wires Connect remaining wires to outer terminal block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements A F Connect ground wir...

Страница 10: ...4 19 mm UL Listed strain relief Put the threaded section of the strain relief C through the hole below the terminal block opening B Reaching inside the terminal block opening screw the removable conduit connector A onto the strain relief threads A B C 1 Attach direct wire strain relief Put direct wire cable through the strain relief The strain relief should have a tight fit with the dryer cabinet ...

Страница 11: ... wire green or bare F of direct wire cable to external ground conductor screw A Tighten screw Place hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hooked ends together and tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 5 Connect ...

Страница 12: ...eze hooked end together Tighten screw 3 Connect neutral wire 1 Prepare to connect neutral ground wire and neutral wire A E B Remove center terminal block screw B Remove neutral ground wire E from external ground conductor screw A E B C Connect neutral ground wire E and neutral wire white or center wire C of power supply cord or cable under center terminal block screw B Tighten screw 3 Connect rema...

Страница 13: ...l vent Recommended for best drying performance and to avoid crushing and kinking Flexible metal vent Acceptable only if accessible to clean Must be fully extended and supported in final dryer location Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance Do not install in enclosed walls ceilings or floors The total length should not exceed 73 4 ft 2 4 m...

Страница 14: ...tional side exhaust outlet A B C A Standard rear offset exhaust installation B Left or right side exhaust installation C Bottom exhaust installation Optional exhaust installations Exhaust can be converted out the right side left side or through the bottom 4 way vent kit Each kit includes step by step instructions For ordering information see Venting Kits Alternate installations for close clearance...

Страница 15: ...hart Exhaust systems longer than those specified will Shorten life of dryer Reduce performance resulting in longer drying times and increased energy usage NOTE Side and bottom exhaust installations have a 90º turn inside the dryer To determine maximum exhaust length add one 90º turn to the chart Install Vent System 12 min 305 mm 12 min 305 mm 1 Install exhaust hood Install exhaust hood and use cau...

Страница 16: ...fit over dryer exhaust outlet and inside exhaust hood Check that vent is secured to exhaust hood with a 4 102 mm clamp 2 Move dryer to final location Move dryer to final location Avoid crushing or kinking vent After dryer is in place remove corner posts and cardboard from under the dryer 1 Level dryer Not Level LEVEL Not Level Check levelness of dryer from side to side Repeat from front to back NO...

Страница 17: ...amp cloth to remove any dust Read Dryer Use in your Use and Care Guide Set the dryer on a full heat cycle not an air cycle for 20 minutes and start the dryer If the dryer will not start check the following Controls are set in a running or On position Start button has been pushed firmly Dryer is plugged into an outlet and or electrical supply is on Household fuse is intact and tight or circuit brea...

Страница 18: ... door over towel on dryer grasp sides of outer door and lift to separate it from inner door NOTE Do not pry apart with putty knife or screwdriver Do not pull on door seal or plastic door catches 5 Remove screws from door Remove screws attaching hinges to door 4 Remove screws from hinges 9 Remove and transfer plugs Remove the four screws that attach two plugs on the left side Transfer plugs to oppo...

Страница 19: ...ple may be needed to reinstall door Insert screws into the bottom holes on left side of dryer cabinet Tighten screws halfway Position door so large end of door hinge slot is over screws Slide door up so screws are in bottom of slots Tighten screws Insert and tighten top screws in hinges TROUBLESHOOTING See the Use and Care Guide or visit our website and reference Frequently Asked Questions to poss...

Страница 20: ...NOTES W11045669A W11045670A SP 05 17 TM 2017 Maytag All rights reserved ...

Отзывы: