130116 v3.2
Operating Instructions SG-EFS 1X4 ZK2/1 8k2
Page 9/15
Polymer Electric
1. Make sure no sensors are activated.
-
yellow LEDs “K1 ON“ and “K2 ON“ are on
-
contacts of switching channels 1 and 2 closed
-
signal circuit open
2. Activate a sensor.
-
yellow LEDs “K1 ON“ and “K2 ON“ go off
-
contacts of switching channels 1 and 2 open
-
signal circuit closed
3. Repeat step 1.
4. Disconnect the sensor.
-
yellow LEDs “K1 ON“ and “K2 ON“ go off
-
contacts of switching channels 1 and 2 open
-
signal circuit closed
Manual reset
For manual reset (with reset), a switch must be connected between cable terminals
5 and 6. The control unit reacts when the switch changes from “not activated“ to
“activated“, i.e. if the switch sticks, no reset command is initialised.
Ä
Remove the bridge between cable terminals 7 and 8.
Ä
Wire up a switch between cable terminals 5 and 6.
Test function: automatic reset
Commissioning
1. Make sure the plug connections are firmly attached.
2. Connect the supply voltage.
Danger of injury due to electrocution!
Ä
Never disconnect terminals with the power on.
Ä
Never unplug plug connections with the power on.
WARNING