background image

Installation and Operating Instructions for

 

ROBA

®

-multiswitch Type 019._00.2 

(B.019+002.EN)

29/03/2022 GC/TH/MA/SU

Page 1 of 6

Chr. Mayr GmbH + Co. KG
Eichenstraße 1, D-87665 Mauerstetten, Germany
Tel.: +49 8341 804-0, Fax: +49 8341 804-421

www.mayr.com

, E-Mail: 

[email protected]

Guidelines on the Declaration of Conformity

A conformity evaluation has been carried out for the product in terms of the EC Low Voltage Directive 2014/35/
EU and EMC Directive 2014/30/EU. The Declaration of Conformity is laid out in writing in a separate document 
and can be requested if required.

Guidelines on the EMC Directive (2014/30/EU)

The product cannot be operated independently according to the EMC directive. 
Only after integration of the product into an overall system can this be evaluated in terms of the EMC. 
For electronic equipment, the evaluation has been verified for the individual product in laboratory conditions, 
but not in the overall system.

Guidelines on the Machinery Directive (2006/42/EC)

The product is a component for installation into machines according to the machinery directive 2006/42/EC. 
The product can fulfil the specifications for safety-related applications in coordination with other elements. 
The type and scope of the required measures result from the machine risk analysis. 
The product then becomes a machine component and the machine manufacturer assesses the conformity 
of the safety device to the directive. It is forbidden to start use of the product until you have ensured that the 
machine accords with the regulations stated in the directive.

Guidelines on the ATEX Directive

Without a conformity evaluation, this product is not suitable for use in areas where there is a high danger 
of explosion. For application of this product in areas where there is a high danger of explosion, it must be 
classified and marked according to directive 2014/34/EU.

Safety and Guideline Signs

DANGER

Immediate and impending danger, which 
can lead to severe physical injuries or to 
death.

CAUTION

Danger of injury to personnel and damage 
to machines

Guidelines on important points

General Safety Guidelines

DANGER

Danger of death! Do not touch voltage-
carrying lines and components.

DANGER

Danger of burns when touching hot 
surfaces

CAUTION

•  Danger from devices caused by short-

circuits and earth short-circuits at the 
terminals

•  Electronic devices cannot be guaranteed 

fail-safe.

During the risk assessment required when designing the 
machine or system, the dangers involved must be evaluated 
and removed by taking appropriate protective measures. 
To prevent injury or damage, only professionals and 
specialists are allowed to work on the devices. They must 
be familiar with the dimensioning, transport, installation, 
initial operation, maintenance and disposal according to the 
relevant standards and regulations.

Before product installation and initial 
operation, please read the Installation 
and Operational Instructions carefully and 
observe the Safety Regulations. Incorrect 
operation can cause injury or damage.

11

Содержание ROBA-multiswitch 019.00.2 Series

Страница 1: ...o the directive It is forbidden to start use of the product until you have ensured that the machine accords with the regulations stated in the directive Guidelines on the ATEX Directive Without a conformity evaluation this product is not suitable for use in areas where there is a high danger of explosion For application of this product in areas where there is a high danger of explosion it must be ...

Страница 2: ...oltage for 50 ms and then adjusts automatically to a pre programmed overexcitation voltage After the overexcitation time ends it regulates to the permanently programmed holding voltage For the overexcitation voltage and holding voltage values of the standard design please see the Table at the bottom of page 3 On special designs deviating values are possible The overexcitation time can be adjusted ...

Страница 3: ...mperature C 40 to 70 Conformity markings Installation conditions The installation position can be user defined Please ensure sufficient heat dissipation and air convection Do not install near to sources of intense heat Special designs with other input and output voltages as well as longer overexcitation times are available on request On special designs deviating values are possible The values stat...

Страница 4: ...n series reduces wear If a longer brake engagement time or a quieter switching noise is required please switch AC side For this a bridge must be installed between terminals 3 and 4 Device Fuses To protect against damage from short circuits or earth short circuits please add suitable device fuses to the mains cable As an alternative a motor protection switch can be used This must be adjusted to the...

Страница 5: ...s Type tag PO W Coil capacity on overexcitation PO UO x PN UN PH W Coil capacity at reduced capacity PH UH x PN UN tO s Overexcitation time tH s Time of operation with reduction in capacity toff s Time without voltage ton s Time with voltage T s Total time tO tH toff UO V Overexcitation voltage bridge voltage UH V Holding voltage half wave voltage UN V Coil nominal voltage Ieff A RMS current depen...

Страница 6: ...ot form ring or bow shapes with the cables Mount good earth connections onto the metal body of the brake Lay control cables separately from power cables or from strongly pulsating cables During operation with a frequency converter please ensure EMC compatible installation of the frequency converter Please always check the holding voltage of the ROBA multiswitch during operation of all components i...

Отзывы: