Mayr EAS-compact 493. 4 .0 Series Скачать руководство пользователя страница 1

Installation and Operating Instructions for 
EAS

®

-compact

®

 clutch Type 493._ 4 _ .0    Sizes 01 – 1 

(B.4.16.GB)

 

 

10/03/2005 K/TK/Kr 

Chr. Mayr GmbH + Co. KG 

Tel.: 08341 / 804-0 

 

Eichenstraße 1 

Fax: 08341 / 804-421 

 

87665 Mauerstetten 

http://www.mayr.de 

Page 1 of 5 

Germany 

eMail: 

info@mayr.de

 

Please read and observe this Operating Instruction carefully. 

A possible malfunction or failure of the clutch and any damage may be caused by not observing it. 

 
 

Table of contents: 

 

Page 1:  - Table of contents 

 

- Manufacturer’s declaration 

 

- Safety regulations 

Page 2:  - Clutch view 

 

- Parts list 

Page 3:  - Design 

 

- Supply condition 

 

- Function 

 

- Important mounting instructions 

 

- Assembly 

 

- Table 1: Screw tightening torques 

 

- Assembly of the limit switch 

Page 4:  - Torque adjustment (at the factory) 

 

- Adjusting the torque 

Page 5:  - Permissible shaft misalignments 

 

- Table 2: Misalignment values 

 

- Alignment of the coupling 

 

- Maintenance 

 

- Disposal 

 
 
 
 
 
 
 
 
 
 

 
 
 
 

Manufacturer’s declaration 

The product is a component within the scope of the Machinery directive 98/37/EC for installation into machines or equipment. 

 An initial start-up is prohibited until it has been noticed that the machinery or the equipment into which this product has been incorporated 
correspond to the EC-guidelines. 

Safety regulations 

The submitted installation and operating instructions (E+B) is part of the clutch shipment. 
Keep the E+B always well accessible near the clutch. 

 

Danger! 

 

If the EAS

®

-clutches have been modified or reconverted. 

 

If the relevant standards of the safety or installation conditions are not observed. 

Necessary protective measures to be undertaken by the user 

 

Cover all moving parts for protection against squeezing, seizing, dust deposit and hit of foreign objects.   

 

The clutches must not be put into operation without limit switch, unless with mayr

®

 not otherwise agreed. 

Only qualified and well-trained specialists should work on the units to avoid any personal injury or damage to 
machinery under observance of the valid standards and guidelines. The installation and operating instructions 
are to be read carefully before installation and operation
 

With these safety notes no claim on completeness is raised! 

Attention: 
Based on the guideline 94/9/EC (ATEX-guideline) this product is not suitable for the application in potential explosive areas without 
evaluation of the conformity. 

 