To avoid battery acid splashing, the cell caps should be replaced but not tightened until charging is complete.  
This allows any gases formed during charging to escape. It is inevitable that some minor escape of acid will 
occur  during  charging.  If  your  battery  is  permanently  sealed  it  is  unnecessary  to  carry  out  these  checks. 

 
2. 

CHARGING LEAD SELECTION 

Interchangeable  ring  terminal  and  fully-insulated  battery  clip  charging  leads  are  supplied.  Select  the 
appropriate lead for your application and attach to the charger output lead using the quick-fit connector fitted 
to each, before connecting the charger to either the mains supply or to the battery. 

NOTE :

 Quick fit ring 

terminal leads are useful for applications where the battery is not easily accessible, as with some motorcycles. 

 
3. 

CONNECTION 

To avoid sparks which could cause an explosion, the mains supply should always be disconnected before 
making  or  breaking  battery  connections.  Connect  the  battery  clips  or  ring  terminals  to  the  battery  in  the 
following order: 

1) 

Connect the positive charging lead (RED) to the positive post of the battery ( / +ve or P). 

2)  For  vehicles with  the  battery  still  installed:   

Connect  the  negative  charging  lead  (BLACK)  to  the               

vehicle chassis (marked - / -ve or N), well away from the battery, fuel line, and hot or moving parts. 

For batteries removed from the vehicle:

  Connect the negative charging lead (BLACK) to the negative 

post of the battery (marked - / -ve or N). 

 
After connecting the clips, rotate them slightly so as to remove any dirt or oxidization, thus ensuring a good 
contact. 

 
4. 

CHARGING 

WARNING!  DO NOT ATTEMPT TO START THE VEHICLE WITH THE CHARGER CONNECTED TO 
THE BATTERY. THIS MAY DAMAGE YOUR BATTERY CHARGER. 

1) 

Switch on the mains power supply.  For 12V batteries select the charging mode appropriate for your 
battery by pushing the 

MODE

 button. The display will cycle through the available options (12V STD, 

12V AGM,  WINTER).  The  charger  will  now  automatically  measure  the  voltage  of  your  battery  and 
diagnose its condition.  Providing the battery is in an acceptable  condition the charge cycle will now 
commence and the LCD display will now show charging information. For 6V batteries the charger will 
automatically commence the 6V STD charging program.

 

2) 

When the battery is fully charged with 5 bars shown on the display, the charger will switch to provide a 
maintenance float charge and may be left connected to the battery.

 

 
The 5 step charging program is: 

1) 

Battery condition diagnosis & recovery with pulse charging 

2) 

Battery preparation with soft start 

3) 

Automatic current selection & bulk charging - charging with constant current 

4) 

Constant voltage absorption charging, after which charging ceases automatically for 1 minute. 

5) 

Maintenance float charging - When the battery is fully charged the charger will maintain the condition of 
your battery automatically through voltage monitoring and pulse charging. 

 

5. 

WHEN  CHARGING IS COMPLETE 

Switch off the mains supply, unplug the charger & disconnect the clips from the battery, negative (BLACK 
lead) first. Then disconnect the (RED) positive lead from the battery. Or, if used, disconnect the ring terminal 
charging lead in the same way. The lead can be left permanently attached to a vehicle battery 

but the end-

cap must be fitted at all times to prevent short circuit, sparks or dirt/water entry.

 When not in use the 

charger should NOT be left connected to this lead. 